Arterial input function placement effect on computed tomography lung perfusion maps.

Laura Jimenez-Juan1, Hatem Mehrez1, Chris Dey1, Shabnam Homampour1, Anastasia Oikonomou1, Fatima Ursani1, Narinder Paul1.   

Abstract

BACKGROUND: A critical source of variability in dynamic perfusion computed tomography (DPCT) is the arterial input function (AIF). However, the impact of the AIF location in lung DPCT has not been investigated yet. The purpose of this study is to determine whether the location of the AIF within the central pulmonary arteries influences the accuracy of lung DPCT maps.
METHODS: A total of 54 lung DPCT scans were performed in three pigs using different rates and volumes of iodinated contrast media. Pulmonary blood flow (PBF) perfusion maps were generated using first-pass kinetics in three different AIF locations: the main pulmonary trunk (PT), the right main (RM) and the left main (LM) pulmonary arteries. A total of 162 time density curves (TDCs) and corresponding PBF perfusion maps were generated. Linear regression and Spearman's rank correlation coefficient were used to compare the TDCs. PBF perfusion maps were compared quantitatively by taking twenty six regions of interest throughout the lung parenchyma. Analysis of variance (ANOVA) was used to compare the mean PBF values among the three AIF locations. Two chest radiologists performed qualitative assessment of the perfusion maps using a 3-point scale to determine regions of perfusion mismatch.
RESULTS: The linear regression of the TDCs from the RM and LM compared to the PT had a median (range) of 1.01 (0.98-1.03). The Spearman rank correlation between the TDCs was 0.88 (P<0.05). ANOVA analysis of the perfusion maps demonstrated no statistical difference (P>0.05). Qualitative comparison of the perfusion maps resulted in scores of 1 and 2, demonstrating either identical or comparable maps with no significant difference in perfusion defects between the different AIF locations.
CONCLUSIONS: Accurate PBF perfusion maps can be generated with the AIF located either at the PT, RM or LM pulmonary arteries.

Entities:  

Keywords:  Perfusion imaging; computed tomography (CT); pulmonary artery

Year:  2016        PMID: 26981452      PMCID: PMC4775248          DOI: 10.3978/j.issn.2223-4292.2016.01.05

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  26 in total

1.  Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

Authors:  F Calamante; D G Gadian; A Connelly
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

Review 2.  Perfusion CT: a worthwhile enhancement?

Authors:  K A Miles; M R Griffiths
Journal:  Br J Radiol       Date:  2003-04       Impact factor: 3.039

Review 3.  Sources of variability in computed tomography perfusion: implications for acute stroke management.

Authors:  Benjamin Zussman; Pascal Jabbour; Kiran Talekar; Richard Gorniak; Adam E Flanders
Journal:  Neurosurg Focus       Date:  2011-06       Impact factor: 4.047

Review 4.  Perfusion CT for the assessment of tumour vascularity: which protocol?

Authors:  K A Miles
Journal:  Br J Radiol       Date:  2003       Impact factor: 3.039

Review 5.  One-stop-shop stroke imaging with functional CT.

Authors:  Elizabeth Tong; Peter Komlosi; Max Wintermark
Journal:  Eur J Radiol       Date:  2014-12-03       Impact factor: 3.528

6.  Dynamic MR perfusion imaging: capability for quantitative assessment of disease extent and prediction of outcome for patients with acute pulmonary thromboembolism.

Authors:  Yoshiharu Ohno; Hisanobu Koyama; Keiko Matsumoto; Yumiko Onishi; Munenobu Nogami; Daisuke Takenaka; Takeshi Yoshikawa; Sumiaki Matsumoto; Kazuro Sugimura
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

7.  Multislice computed tomography perfusion imaging for visualization of acute pulmonary embolism: animal experience.

Authors:  Joachim Ernst Wildberger; Ernst Klotz; Hendrik Ditt; Elmar Spüntrup; Andreas H Mahnken; Rolf W Günther
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

8.  Perfusion evaluation of lung cancer: assessment using dual-input perfusion computed tomography.

Authors:  Sachiko Nakano; Junko Gibo; Yasuhiro Fukushima; Kyoichi Kaira; Noriaki Sunaga; Ayako Taketomi-Takahashi; Yoshito Tsushima; Masatomo Mori
Journal:  J Thorac Imaging       Date:  2013-07       Impact factor: 3.000

Review 9.  CT perfusion of the liver: principles and applications in oncology.

Authors:  Se Hyung Kim; Aya Kamaya; Jürgen K Willmann
Journal:  Radiology       Date:  2014-08       Impact factor: 11.105

10.  An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT.

Authors:  Haitao Sun; Fei Gao; Ning Li; Cheng Liu
Journal:  Acta Radiol       Date:  2013-05-23       Impact factor: 1.990

View more
  1 in total

1.  Quantitative assessment of pulmonary artery occlusion using lung dynamic perfusion CT.

Authors:  Laura Jimenez-Juan; Hatem Mehrez; Chris Dey; Shabnam Homampour; Pascal Salazar-Ferrer; John T Granton; Ting-Yim Lee; Narinder Paul
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

  1 in total