BACKGROUND: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs.
PURPOSE: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion.
MATERIAL AND METHODS: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups.
RESULTS: Regional PBF (94.2 ± 36.5, 161.8 ± 29.6, 185.7 ± 38.1 and 125.5 ± 46.1, 161.9 ± 31.4, 169.3 ± 51.7), PBV (6.7 ± 2.8, 10.9 ± 3.0, 12.9 ± 4.5 and 9.9 ± 4.6, 10.3 ± 2.9, 11.9 ± 4.5), and MTT (5.8 ± 2.4, 4.5 ± 1.3, 4.7 ± 2.1 and 5.6 ± 2.3, 4.3 ± 1.5, 4.9 ± 1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 ± 30.6 vs. 94.9 ± 15.9) and PBV (11.1 ± 4.0 vs. 6.6 ± 1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm.
CONCLUSION: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

Entities:  

Keywords:  CT; Lung; emphysema; perfusion; pulmonary embolism

Mesh:

Year:  2013        PMID: 23761560     DOI: 10.1177/0284185113490151

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Arterial input function placement effect on computed tomography lung perfusion maps.

Authors:  Laura Jimenez-Juan; Hatem Mehrez; Chris Dey; Shabnam Homampour; Anastasia Oikonomou; Fatima Ursani; Narinder Paul
Journal:  Quant Imaging Med Surg       Date:  2016-02

2.  Quantitative assessment of pulmonary artery occlusion using lung dynamic perfusion CT.

Authors:  Laura Jimenez-Juan; Hatem Mehrez; Chris Dey; Shabnam Homampour; Pascal Salazar-Ferrer; John T Granton; Ting-Yim Lee; Narinder Paul
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.