Literature DB >> 21631232

Sources of variability in computed tomography perfusion: implications for acute stroke management.

Benjamin Zussman1, Pascal Jabbour, Kiran Talekar, Richard Gorniak, Adam E Flanders.   

Abstract

OBJECT: Although dynamic, first-pass cerebral CT perfusion is used in the evaluation of acute ischemic stroke, a lack of standardization restricts the value of this imaging modality in clinical decision-making. The purpose of this study was to comprehensively review the reported sources of variability and error in cerebral CT perfusion results.
METHODS: A systematic literature review was conducted, 120 articles were reviewed, and 23 published original research articles were included. Sources of variability and error were thematically categorized and presented within the context of the 3 stages of a typical CT perfusion study: data acquisition, postprocessing, and results interpretation.
RESULTS: Seven factors that caused variability were identified and described in detail: 1) contrast media, the iodinated compound injected intravascularly to permit imaging of the cerebral vessels; 2) data acquisition rate, the number of images obtained by CT scan per unit time; 3) user inputs, the subjective selections that operators make; 4) observer variation, the failure of operators to repeatedly measure a perfusion parameter with precision; 5) software operational mode, manual, semiautomatic, or automatic; 6) software design, the mathematical algorithms used to perform postprocessing; and 7) value type, absolute versus relative values.
CONCLUSIONS: Standardization at all 3 stages of the CT perfusion study cycle is warranted. At present, caution should be exercised when interpreting CT perfusion results as these values may vary considerably depending on a variety of factors. Future research is needed to define the role of CT perfusion in clinical decision-making for acute stroke patients and to determine the clinically acceptable limits of variability in CT perfusion results.

Entities:  

Mesh:

Year:  2011        PMID: 21631232     DOI: 10.3171/2011.3.FOCUS1136

Source DB:  PubMed          Journal:  Neurosurg Focus        ISSN: 1092-0684            Impact factor:   4.047


  4 in total

1.  Standardization of Stroke Perfusion CT for Reperfusion Therapy.

Authors:  Guangming Zhu; Patrik Michel; Weiwei Zhang; Max Wintermark
Journal:  Transl Stroke Res       Date:  2012-03-28       Impact factor: 6.829

2.  Arterial input function placement effect on computed tomography lung perfusion maps.

Authors:  Laura Jimenez-Juan; Hatem Mehrez; Chris Dey; Shabnam Homampour; Anastasia Oikonomou; Fatima Ursani; Narinder Paul
Journal:  Quant Imaging Med Surg       Date:  2016-02

3.  Optimisation of vascular input and output functions in CT-perfusion imaging using 256(or more)-slice multidetector CT.

Authors:  Joris M Niesten; Irene C van der Schaaf; Alan J Riordan; Hugo W A M de Jong; Willem P T M Mali; Birgitta K Velthuis
Journal:  Eur Radiol       Date:  2012-11-29       Impact factor: 5.315

4.  ESR statement on the stepwise development of imaging biomarkers.

Authors: 
Journal:  Insights Imaging       Date:  2013-02-09
  4 in total