Literature DB >> 26978664

Design Features and Mutual Compatibility Studies of the Time-of-Flight PET Capable GE SIGNA PET/MR System.

Craig S Levin, Sri Harsha Maramraju, Mohammad Mehdi Khalighi, Timothy W Deller, Gaspar Delso, Floris Jansen.   

Abstract

A recent entry into the rapidly evolving field of integrated PET/MR scanners is presented in this paper: a whole body hybrid PET/MR system (SIGNA PET/MR, GE Healthcare) capable of simultaneous acquisition of both time-of-flight (TOF) PET and high resolution MR data. The PET ring was integrated into an existing 3T MR system resulting in a (patient) bore opening of 60 cm diameter, with a 25 cm axial FOV. PET performance was evaluated both on the standalone PET ring and on the same detector integrated into the MR system, to assess the level of mutual interference between both subsystems. In both configurations we obtained detector performance data. PET detector performance was not significantly affected by integration into the MR system. The global energy resolution was within 2% (10.3% versus 10.5%), and the system coincidence time resolution showed a maximum change of < 3% (385 ps versus 394 ps) when measured outside MR and during simultaneous PET/MRI acquisitions, respectively. To evaluate PET image quality and resolution, the NEMA IQ phantom was acquired with MR idle and with MR active. Impact of PET on MR IQ was assessed by comparing SNR with PET acquisition on and off. B0 and B1 homogeneities were acquired before and after the integration of the PET ring inside the magnet. In vivo brain and whole body head-to-thighs data were acquired to demonstrate clinical image quality.

Entities:  

Mesh:

Year:  2016        PMID: 26978664     DOI: 10.1109/TMI.2016.2537811

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  42 in total

1.  Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.

Authors:  Andrew P Leynes; Jaewon Yang; Florian Wiesinger; Sandeep S Kaushik; Dattesh D Shanbhag; Youngho Seo; Thomas A Hope; Peder E Z Larson
Journal:  J Nucl Med       Date:  2017-10-30       Impact factor: 10.057

Review 2.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

3.  Summary of the First ISMRM-SNMMI Workshop on PET/MRI: Applications and Limitations.

Authors:  Thomas A Hope; Zahi A Fayad; Kathryn J Fowler; Dawn Holley; Andrei Iagaru; Alan B McMillan; Patrick Veit-Haiback; Robert J Witte; Greg Zaharchuk; Ciprian Catana
Journal:  J Nucl Med       Date:  2019-05-23       Impact factor: 10.057

4.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

Review 5.  Update on novel trends in PET/CT technology and its clinical applications.

Authors:  Stephan Walrand; Michel Hesse; François Jamar
Journal:  Br J Radiol       Date:  2016-11-25       Impact factor: 3.039

6.  Image-derived input function estimation on a TOF-enabled PET/MR for cerebral blood flow mapping.

Authors:  Mohammad Mehdi Khalighi; Timothy W Deller; Audrey Peiwen Fan; Praveen K Gulaka; Bin Shen; Prachi Singh; Jun-Hyung Park; Frederick T Chin; Greg Zaharchuk
Journal:  J Cereb Blood Flow Metab       Date:  2017-02-03       Impact factor: 6.200

7.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

Review 8.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

Review 9.  Update on latest advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2020-11-16       Impact factor: 2.685

10.  Estimation of Crystal Timing Properties and Efficiencies for the Improvement of (Joint) Maximum-Likelihood Reconstructions in TOF-PET.

Authors:  Ahmadreza Rezaei; Georg Schramm; Koen Van Laere; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2019-08-28       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.