Literature DB >> 25462724

Redox gradients in distribution systems influence water quality, corrosion, and microbial ecology.

Sheldon Masters1, Hong Wang, Amy Pruden, Marc A Edwards.   

Abstract

Simulated distribution systems (SDSs) defined the interplay between disinfectant type (free chlorine and chloramines), water age (1-10.2 days), and pipe material (PVC, iron and cement surfaces) on water chemistry, redox zones and infrastructure degradation. Redox gradients developed as a function of water age and pipe material affected the quality of water consumers would receive. Free chlorine was most stable in the presence of PVC while chloramine was most stable in the presence of cement. At a 3.6 day water age the residual in the chlorinated PVC SDS was more than 3.5 times higher than in the chlorinated iron or cement systems. In contrast, the residual in the chloraminated cement SDS was more than 10 times greater than in the chloraminated iron or PVC systems. Near the point of entry to the SDSs where disinfectant residuals were present, free chlorine tended to cause as much as 4 times more iron corrosion when compared to chloramines. Facultative denitrifying bacteria were ubiquitous, and caused complete loss of nitrogen at distal points in systems with iron, and these bacteria co-occurred with very severe pitting attack (1.6-1.9 mm/year) at high water age.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25462724     DOI: 10.1016/j.watres.2014.09.048

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Distribution system water age can create premise plumbing corrosion hotspots.

Authors:  Sheldon Masters; Jeffrey Parks; Amrou Atassi; Marc A Edwards
Journal:  Environ Monit Assess       Date:  2015-08-07       Impact factor: 2.513

2.  Inherent variability in lead and copper collected during standardized sampling.

Authors:  Sheldon Masters; Jeffrey Parks; Amrou Atassi; Marc A Edwards
Journal:  Environ Monit Assess       Date:  2016-02-20       Impact factor: 2.513

3.  Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

Authors:  Isabella Marchesi; Greta Ferranti; Antonella Mansi; Anna M Marcelloni; Anna R Proietto; Navneet Saini; Paola Borella; Annalisa Bargellini
Journal:  Appl Environ Microbiol       Date:  2016-05-02       Impact factor: 4.792

Review 4.  Microbial diversity in full-scale water supply systems through sequencing technology: a review.

Authors:  Wei Zhou; Weiying Li; Jiping Chen; Yu Zhou; Zhongqing Wei; Longcong Gong
Journal:  RSC Adv       Date:  2021-07-22       Impact factor: 4.036

5.  Impact of Water Chemistry, Pipe Material and Stagnation on the Building Plumbing Microbiome.

Authors:  Pan Ji; Jeffrey Parks; Marc A Edwards; Amy Pruden
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

  5 in total