A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic system.

Zhihua Pu1, Chongwei Zou1, Ridong Wang1, Xiaochen Lai1, Haixia Yu2, Kexin Xu1, Dachao Li1.   

Abstract

This paper presents a continuous glucose monitoring microsystem consisting of a three-electrode electrochemical sensor integrated into a microfluidic chip. The microfluidic chip, which was used to transdermally extract and collect subcutaneous interstitial fluid, was fabricated from five polydimethylsiloxane layers using micromolding techniques. The electrochemical sensor was integrated into the chip for continuous detection of glucose. Specifically, a single-layer graphene and gold nanoparticles (AuNPs) were decorated onto the working electrode (WE) of the sensor to construct a composite nanostructured surface and improve the resolution of the glucose measurements. Graphene was transferred onto the WE surface to improve the electroactive nature of the electrode to enable measurements of low levels of glucose. The AuNPs were directly electrodeposited onto the graphene layer to improve the electron transfer rate from the activity center of the enzyme to the electrode to enhance the sensitivity of the sensor. Glucose oxidase (GOx) was immobilized onto the composite nanostructured surface to specifically detect glucose. The factors required for AuNPs deposition and GOx immobilization were also investigated, and the optimized parameters were obtained. The experimental results displayed that the proposed sensor could precisely measure glucose in the linear range from 0 to 162 mg/dl with a detection limit of 1.44 mg/dl (S/N = 3). The proposed sensor exhibited the potential to detect hypoglycemia which is still a major challenge for continuous glucose monitoring in clinics. Unlike implantable glucose sensors, the wearable device enabled external continuous monitoring of glucose without interference from foreign body reaction and bioelectricity.

Entities:  

Year:  2016        PMID: 26958097      PMCID: PMC4769273          DOI: 10.1063/1.4942437

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  9 in total

1.  Graphical and numerical evaluation of continuous glucose sensing time lag.

Authors:  Boris P Kovatchev; Devin Shields; Marc Breton
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

2.  All I want for Christmas….

Authors:  Holger Becker
Journal:  Lab Chip       Date:  2011-03-24       Impact factor: 6.799

3.  Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing.

Authors:  Changsheng Shan; Huafeng Yang; Dongxue Han; Qixian Zhang; Ari Ivaska; Li Niu
Journal:  Biosens Bioelectron       Date:  2009-10-01       Impact factor: 10.618

4.  An automated telemedicine system improves patient-reported well-being.

Authors:  Mona Boaz; Katerina Hellman; Julio Wainstein
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

5.  Determination of glucose levels using a functionalized hydrogel-optical fiber biosensor: toward continuous monitoring of blood glucose in vivo.

Authors:  Sven Tierney; Berit M Hasle Falch; Dag Roar Hjelme; Bjørn Torger Stokke
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

6.  A Capacitive MEMS Viscometric Sensor for Affinity Detection of Glucose.

Authors:  Xian Huang; Siqi Li; Jerome Schultz; Qian Wang; Qiao Lin
Journal:  J Microelectromech Syst       Date:  2009-11-13       Impact factor: 2.417

7.  Graphene wrapped Cu2O nanocubes: non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with enhanced stability.

Authors:  Minmin Liu; Ru Liu; Wei Chen
Journal:  Biosens Bioelectron       Date:  2013-02-16       Impact factor: 10.618

8.  Rapid skin permeabilization by the simultaneous application of dual-frequency, high-intensity ultrasound.

Authors:  Carl M Schoellhammer; Baris E Polat; Jonathan Mendenhall; Ruby Maa; Brianna Jones; Douglas P Hart; Robert Langer; Daniel Blankschtein
Journal:  J Control Release       Date:  2012-08-23       Impact factor: 9.776

Review 9.  Towards smart tattoos: implantable biosensors for continuous glucose monitoring.

Authors:  Yun Jung Heo; Shoji Takeuchi
Journal:  Adv Healthc Mater       Date:  2012-11-26       Impact factor: 9.933

  9 in total
  6 in total

1.  Preface to Special Topic: Selected Papers from the 5th International Conference on Optofluidics.

Authors:  Shih-Kang Fan; Zhenchuan Yang
Journal:  Biomicrofluidics       Date:  2016-02-29       Impact factor: 2.800

2.  A graphene aptasensor for biomarker detection in human serum.

Authors:  Xuejun Wang; Yibo Zhu; Timothy R Olsen; Na Sun; Wenjun Zhang; Renjun Pei; Qiao Lin
Journal:  Electrochim Acta       Date:  2018-09-13       Impact factor: 6.901

Review 3.  Advanced wearable biosensors for the detection of body fluids and exhaled breath by graphene.

Authors:  Santoshi U Singh; Subhodeep Chatterjee; Shahbaz Ahmad Lone; Hsin-Hsuan Ho; Kuldeep Kaswan; Kiran Peringeth; Arshad Khan; Yun-Wei Chiang; Sangmin Lee; Zong-Hong Lin
Journal:  Mikrochim Acta       Date:  2022-05-28       Impact factor: 6.408

Review 4.  Functionalized microneedles for continuous glucose monitoring.

Authors:  Kai Takeuchi; Beomjoon Kim
Journal:  Nano Converg       Date:  2018-10-24

5.  A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring.

Authors:  Zhihua Pu; Xingguo Zhang; Haixia Yu; Jiaan Tu; Hailong Chen; Yuncong Liu; Xiao Su; Ridong Wang; Lei Zhang; Dachao Li
Journal:  Sci Adv       Date:  2021-01-27       Impact factor: 14.136

Review 6.  Integration of Different Graphene Nanostructures with PDMS to Form Wearable Sensors.

Authors:  Shan He; Yang Zhang; Jingrong Gao; Anindya Nag; Abdul Rahaman
Journal:  Nanomaterials (Basel)       Date:  2022-03-14       Impact factor: 5.076

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.