Literature DB >> 19323502

Determination of glucose levels using a functionalized hydrogel-optical fiber biosensor: toward continuous monitoring of blood glucose in vivo.

Sven Tierney1, Berit M Hasle Falch, Dag Roar Hjelme, Bjørn Torger Stokke.   

Abstract

Glucose-selective optical sensors were fabricated by incorporating 3-phenylboronic acid and a tertiary amine, dimethylaminopropylacrylamide, into a hydrogel matrix. Determination of glucose in solution is based on the glucose-induced contraction of the hydrogel. The gel was fabricated on the end of an optical fiber, and the optical length was measured by an interferometric technique. Previously it was found the gel could be tuned for enhanced glucose sensitivity and selectivity by varying the 3-phenylboronic acid/tertiary amine ratio. The properties of the responsive hydrogel as a glucose sensor were determined in more detail with respect to swelling kinetics and equilibrium swelling degree. Temperature effects, size variation, molecular interference, and reversibility were addressed. Results showed there was a good degree of reversibility, both for equilibrium swelling and swelling kinetics. Fabricated hydrogel sensors with slight differences in size yielded an overlapping relative response indicating an excellent degree of sensor reproducibility. The sensor proved to be temperature-dependent; by increasing the temperature from 25 to 37 degrees C, the swelling was about 4-fold more rapid, and a concomitant decrease in equilibrium swelling was seen. Identified interference from other analytes with determination of glucose was used a basis for selecting ethylenediaminetetraacetic acid (EDTA) as an anticoagulant for in vitro determination of glucose concentration in blood plasma. Glucose measurements performed in blood plasma were promising, showing that the sensor is capable of measuring physiological glucose levels in blood with a minimal effect from interfering molecules. The obtained results indicate that the developed sensor is a candidate for continuous monitoring of glucose in blood.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19323502     DOI: 10.1021/ac900019k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  19 in total

1.  A human pilot study of the fluorescence affinity sensor for continuous glucose monitoring in diabetes.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Arun P Pillai; Eric Orzeck; Rafal Drabek; Ashok Gowda; Roger McNichols
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Acute in vivo performance evaluation of the fluorescence affinity sensor in the intravascular and interstitial space in Swine.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Arun P Pillai; Ashok Gowda; Roger McNichols; Jesse Rios; William Cohn
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

Review 3.  Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.

Authors:  Ronald A Siegel
Journal:  J Control Release       Date:  2014-06-28       Impact factor: 9.776

Review 4.  Intracochlear drug delivery systems.

Authors:  Jeffrey T Borenstein
Journal:  Expert Opin Drug Deliv       Date:  2011-05-26       Impact factor: 6.648

5.  Thermodynamic Analysis of the Selectivity Enhancement Obtained by Using Smart Hydrogels That Are Zwitterionic When Detecting Glucose With Boronic Acid Moieties.

Authors:  F Horkay; S H Cho; P Tathireddy; L Rieth; F Solzbacher; J Magda
Journal:  Sens Actuators B Chem       Date:  2011-12-15       Impact factor: 7.460

6.  Passive and wireless, implantable glucose sensing with phenylboronic acid hydrogel-interlayer RF resonators.

Authors:  Manik Dautta; Muhannad Alshetaiwi; Jens Escobar; Peter Tseng
Journal:  Biosens Bioelectron       Date:  2020-01-03       Impact factor: 10.618

7.  Osmotic Swelling Pressure Response of Smart Hydrogels Suitable for Chronically-Implantable Glucose Sensors.

Authors:  G Lin; S Chang; H Hao; P Tathireddy; M Orthner; J Magda; F Solzbacher
Journal:  Sens Actuators B Chem       Date:  2010-01-29       Impact factor: 7.460

8.  A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic system.

Authors:  Zhihua Pu; Chongwei Zou; Ridong Wang; Xiaochen Lai; Haixia Yu; Kexin Xu; Dachao Li
Journal:  Biomicrofluidics       Date:  2016-02-23       Impact factor: 2.800

9.  Surface plasmon resonance fiber sensor for real-time and label-free monitoring of cellular behavior.

Authors:  Yanina Shevchenko; Gulden Camci-Unal; Davide F Cuttica; Mehmet R Dokmeci; Jacques Albert; Ali Khademhosseini
Journal:  Biosens Bioelectron       Date:  2014-01-18       Impact factor: 10.618

Review 10.  Responsive hydrogels for label-free signal transduction within biosensors.

Authors:  Kamila Gawel; David Barriet; Marit Sletmoen; Bjørn Torger Stokke
Journal:  Sensors (Basel)       Date:  2010-04-30       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.