Literature DB >> 26958011

Correlation of ultrasonographic estimated fetal weight with actual birth weight in a tertiary hospital in Lagos, Nigeria.

Cletus Uche Eze1, Livinus Chibuzo Abonyi1, Jerome Njoku1, Udo Okorie1, Olayinka Owonifari1.   

Abstract

BACKGROUND: Sonographic fetal weight estimation is an important component of antenatal care. AIM: To sonographically estimate fetal weight at term and to compare estimated with actual birth weights to determine the validity of estimated fetal weights. SUBJECTS AND METHODS: In the prospective study, a convenience sample of 282 women was recruited. Ethical approval and informed consent of patients were obtained. An experienced sonographer estimated fetal weights by measuring BPD, HC, AC and FL using a scanner with Hadlock 3 weight estimation model. Actual birth weights were measured with a Crown weighing scale by a midwife. Data was analyzed with SPSS software version 17.0 while descriptive and inferential statistics were used to interpret results. Results were tested at error level set at p≤ 0.05.
RESULTS: Mean estimated and actual birth weights were 3378±40g and 3393±60g respectively. Difference between the two means was not significant. Eleven percent of fetuses were sonographically estimated to be microsomic while 14.5% were microsomic at birth; 12.1% were sonographically estimated to be macrosomic but 15.2% were macrosomic at birth. Most macrosomic fetuses were delivered through cesarean section(CS) and fetal weights increased with maternal age and parity.
CONCLUSION: Sonographically estimated fetal weight using Hadlock 3 weight estimation model without validation correlated positively with actual birth weight in a Nigerian population.

Entities:  

Keywords:  Estimated fetal weight; Nigeria; actual birth weight; sonography

Mesh:

Year:  2015        PMID: 26958011      PMCID: PMC4765419          DOI: 10.4314/ahs.v15i4.9

Source DB:  PubMed          Journal:  Afr Health Sci        ISSN: 1680-6905            Impact factor:   0.927


  20 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Validity of ultrasound estimation of fetal weight.

Authors:  P F Chien; P Owen; K S Khan
Journal:  Obstet Gynecol       Date:  2000-06       Impact factor: 7.661

3.  Clinical vs. sonographic estimate of birth weight in term parturients. A randomized clinical trial.

Authors:  N W Hendrix; C S Grady; S P Chauhan
Journal:  J Reprod Med       Date:  2000-04       Impact factor: 0.142

4.  Comparison of clinical versus ultrasound estimation of fetal weight.

Authors:  A Mehdizadeh; R Alaghehbandan; H Horsan
Journal:  Am J Perinatol       Date:  2000       Impact factor: 1.862

5.  Ultrasonographic prediction of term birth weight: how accurate is it?

Authors:  Gerard G Nahum; Harold Stanislaw
Journal:  Am J Obstet Gynecol       Date:  2003-02       Impact factor: 8.661

6.  Sonographic fetal weight estimation - is there more to it than just fetal measurements?

Authors:  Oshri Barel; Ron Maymon; Zvi Vaknin; Josef Tovbin; Noam Smorgick
Journal:  Prenat Diagn       Date:  2013-11-17       Impact factor: 3.050

7.  Accuracy of estimating fetal weight by abdominal palpation.

Authors:  W S Bossak; W N Spellacy
Journal:  J Reprod Med       Date:  1972-08       Impact factor: 0.142

8.  Sonographic EFW and macrosomia: is there an optimum formula to predict diabetic fetal macrosomia?

Authors:  C A Combs; B Rosenn; M Miodovnik; T A Siddiqi
Journal:  J Matern Fetal Med       Date:  2000 Jan-Feb

9.  Ultrasonographic fetal weight estimation: accuracy of formulas and accuracy of examiners by birth weight from 500 to 5000 g.

Authors:  Juozas Kurmanavicius; Tilo Burkhardt; Josef Wisser; Renate Huch
Journal:  J Perinat Med       Date:  2004       Impact factor: 1.901

10.  Clinical versus sonographic estimation of foetal weight in southwest Nigeria.

Authors:  Akinola S Shittu; Oluwafemi Kuti; Ernest O Orji; Niyi O Makinde; Solomon O Ogunniy; Oluwagbemiga O Ayoola; Salami S Sule
Journal:  J Health Popul Nutr       Date:  2007-03       Impact factor: 2.000

View more
  2 in total

1.  Prospective verification of sonographic fetal weight estimators among term parturients in Uganda.

Authors:  Senai Goitom Sereke; Richard Okello Omara; Felix Bongomin; Sarah Nakubulwa; Harriet Nalubega Kisembo
Journal:  BMC Pregnancy Childbirth       Date:  2021-03-04       Impact factor: 3.007

2.  Maternal and fetal characteristics to predict c-section delivery: A scoring system for pregnant women.

Authors:  Rima Irwinda; Rabbania Hiksas; Angga Wiratama Lokeswara; Noroyono Wibowo
Journal:  Womens Health (Lond)       Date:  2021 Jan-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.