Literature DB >> 26949107

Simultaneous multislice imaging in dynamic cardiac MRI at 7T using parallel transmission.

Sebastian Schmitter1, Steen Moeller1, Xiaoping Wu1, Edward J Auerbach1, Gregory J Metzger1, Pierre-François Van de Moortele1, Kâmil Uğurbil1.   

Abstract

PURPOSE: Cardiac MRI at 7T suffers from contrast heterogeneity that can be mitigated with parallel transmission (pTX) and, when performed during breath-hold, from a limited number of slices that can be multiplied with multiband (MB) radiofrequency pulses by simultaneous excitation of multiple slices (SMS). The goal of this study was to apply both approaches simultaneously.
METHODS: Using a 16-channel transmit/receive body coil, pTX SMS was applied with/without CAIPIRINHA with a modified gradient echo cine sequence. Different calibration schemes were investigated for the slice-GRAPPA reconstruction kernels as a function of the cardiac cycle.
RESULTS: Excellent slice separation for MB = 2 was achieved with CAIPIRINHA, with slice leakage values below 3% for 99% of all voxels. A critical finding of this study was the variation of the MB leakage factor in the heart by as much as 30% throughout the cardiac cycle, which was reduced greatly when reconstruction kernels were calibrated on multiple cardiac phases. Acceptable results were still obtained when applying further acceleration with MB = 3 in combination with in-plane GRAPPA. In one case, two-spoke pulses were compared with one-spoke pulses, resulting as expected in improved homogeneity.
CONCLUSION: pTX SMS imaging at 7T can address contrast heterogeneity while allowing larger slice coverage in cardiac MRI performed under breath-hold. Magn Reson Med 77:1010-1020, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  7 Tesla; MB; SMS; cardiac MRI; multiband; pTX

Mesh:

Year:  2016        PMID: 26949107     DOI: 10.1002/mrm.26180

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

2.  Non-Cartesian slice-GRAPPA and slice-SPIRiT reconstruction methods for multiband spiral cardiac MRI.

Authors:  Changyu Sun; Yang Yang; Xiaoying Cai; Michael Salerno; Craig H Meyer; Daniel Weller; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

Review 3.  Parallel Transmission for Ultrahigh Field MRI.

Authors:  Cem M Deniz
Journal:  Top Magn Reson Imaging       Date:  2019-06

Review 4.  Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Authors:  Kamil Uğurbil
Journal:  Neuroimage       Date:  2017-07-08       Impact factor: 6.556

5.  Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold.

Authors:  Sebastian Weingärtner; Steen Moeller; Sebastian Schmitter; Edward Auerbach; Peter Kellman; Chetan Shenoy; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2017-06-05       Impact factor: 4.668

Review 6.  Progress in Imaging the Human Torso at the Ultrahigh Fields of 7 and 10.5 T.

Authors:  Kamil Uğurbil; Pierre-Francois Van de Moortele; Andrea Grant; Edward J Auerbach; Arcan Ertürk; Russell Lagore; Jutta M Ellermann; Xiaoxuan He; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-02       Impact factor: 2.266

7.  Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T.

Authors:  Sebastian Schmitter; Gregor Adriany; Matt Waks; Steen Moeller; Maria Aristova; Alireza Vali; Edward J Auerbach; Pierre-François Van de Moortele; Kamil Ugurbil; Susanne Schnell
Journal:  Magn Reson Med       Date:  2020-03-18       Impact factor: 4.668

8.  Improved simultaneous multislice cardiac MRI using readout concatenated k-space SPIRiT (ROCK-SPIRiT).

Authors:  Omer Burak Demirel; Sebastian Weingärtner; Steen Moeller; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2021-02-10       Impact factor: 3.737

Review 9.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06

10.  ECG Triggering in Ultra-High Field Cardiovascular MRI.

Authors:  Daniel Stäb; Juergen Roessler; Kieran O'Brien; Christian Hamilton-Craig; Markus Barth
Journal:  Tomography       Date:  2016-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.