Literature DB >> 26916657

Application of low injection rate and low contrast agent dose in three-dimensional rotational digital subtraction angiography of the intracranial aneurysm.

Zhimei Gao1, Yongming Zeng2, Jingkun Sun1, Jingjie Yang1, Yang Zhou1, Mi Zhou1, Tingni Song1.   

Abstract

OBJECTIVE: The objective of this article is to explore the feasibility of low injection rate and low contrast agent dose in three-dimensional rotational digital subtraction angiography (3D DSA) of the intracranial aneurysm.
MATERIALS AND METHODS: Fifty-one patients with suspected intracranial aneurysms were included. The catheter tip was kept within the internal carotid artery at the epistropheus level. Patients were divided into three groups randomly according to injection rate: group A (1.5 ml/s, n = 18), group B (2.0 ml/s, n = 18), and group C (3.0 ml/s, n = 15). The noise, signal-to-noise ratio (SNR), and carrier-to-noise ratio (CNR) of C2, C6, M1, and A1 segments were calculated. The continuous subtraction images and reconstructed images were evaluated by two technicians.
RESULTS: No significant differences were found in noise between groups A and B, and groups A and C. Significant differences were found in the SNR and CNR of M1 and A1 segments between groups A and B, and groups B and C, but for C2 and C6 segments, they were not significant. Significant differences were found in the SNR and CNR of all segments between groups A and C. Significant differences were found in the contrast agent dose between all three groups. No significant differences were found in scores evaluated by two physicians between the three groups.
CONCLUSION: The personalized injection protocol of low injection rate and low contrast agent dose in 3D DSA of the intracranial aneurysm is feasible. The application of this protocol can reduce the dose of iodine and obtain satisfactory images.
© The Author(s) 2016.

Entities:  

Keywords:  Digital subtraction angiography; cerebral vascular; contrast medium; imaging quality

Mesh:

Substances:

Year:  2016        PMID: 26916657      PMCID: PMC4984369          DOI: 10.1177/1591019916631980

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  22 in total

Review 1.  Risk of iodinated contrast material--induced nephropathy with intravenous administration.

Authors:  Richard W Katzberg; Brendan J Barrett
Journal:  Radiology       Date:  2007-04-19       Impact factor: 11.105

2.  Comparison of 2D digital subtraction angiography and 3D rotational angiography in the evaluation of dome-to-neck ratio.

Authors:  W Brinjikji; H Cloft; G Lanzino; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2009-01-08       Impact factor: 3.825

3.  Artifacts caused by insufficient contrast medium filling during C-arm cone-beam CT scans: a phantom study.

Authors:  Mitsuaki Terabe; Hajime Ichikawa; Toyohiro Kato; Kichiro Koshida
Journal:  Radiol Phys Technol       Date:  2013-06-18

4.  Three-dimensional volume rendering digital subtraction angiography in comparison with two-dimensional digital subtraction angiography and rotational angiography for detecting aneurysms and their morphological properties in patients with subarachnoid hemorrhage.

Authors:  Fahrettin Kucukay; R Sarper Okten; Ayhan Tekiner; Mustafa Dagli; Cevdet Gocek; Mehmet Akif Bayar; Turhan Cumhur
Journal:  Eur J Radiol       Date:  2011-11-04       Impact factor: 3.528

5.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms.

Authors:  Takeshi Sugahara; Yukunori Korogi; Kouji Nakashima; Satoshi Hamatake; Shin Honda; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

6.  Cerebral microaneurysms found incidentally during aneurysm surgery.

Authors:  J Inamasu; S Suga; T Horiguchi; K Akaji; K Mayanagi; T Kawase
Journal:  Neurol Res       Date:  2001-06       Impact factor: 2.448

7.  3D rotational angiography with volume rendering: the utility in the detection of intracranial aneurysms.

Authors:  Wan-Yin Shi; Yong-Dong Li; Ming-Hua Li; Bin-Xian Gu; Shi-Wen Chen; Wu Wang; Bei-Lei Zhang; Min Li
Journal:  Neurol India       Date:  2010 Nov-Dec       Impact factor: 2.117

8.  CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study.

Authors:  M Piotin; P Gailloud; L Bidaut; S Mandai; M Muster; J Moret; D A Rüfenacht
Journal:  Neuroradiology       Date:  2003-04-26       Impact factor: 2.804

9.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.

Authors:  Albrecht Hochmuth; Uwe Spetzger; Martin Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

Review 10.  Contrast-induced nephropathy: the wheel has turned 360 degrees.

Authors:  H S Thomsen; S K Morcos; B J Barrett
Journal:  Acta Radiol       Date:  2008-07       Impact factor: 1.990

View more
  1 in total

1.  Relationship between Injection Rate and Contrast Enhancement on Three-dimensional Digital Subtraction Angiography of the Cerebral Arteries.

Authors:  Satoshi Takagi; Naoyuki Hanasaki
Journal:  J Belg Soc Radiol       Date:  2018-12-03       Impact factor: 1.894

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.