BACKGROUND AND PURPOSE: Dome-to-neck ratio of intracranial aneurysms is an important predictor of outcomes of endovascular coiling. 3D imaging techniques are increasingly used in evaluating the dome-to-neck ratio of aneurysms for intervention. The purpose of this study was to determine whether 3D rotational angiography (3DRA) can be used to determine accurately the dome-to-neck ratio of intracranial aneurysms when compared with conventional 2D digital subtraction angiography (2D DSA). MATERIALS AND METHODS: A retrospective analysis of 180 patients with 205 intracranial aneurysms who underwent both 2D DSA and 3DRA for evaluation of previously untreated aneurysms was conducted. Dome-to-neck ratios were compared between 2D DSA and 3DRA images. The mean difference in dome-to-neck ratios between 2D DSA and 3DRA was calculated. The proportions of "wide-neck" aneurysms seen on 2D DSA and 3DRA were compared by using 2 different definitions of "wide-neck," including <1.5 and <2.0. RESULTS: The average dome-to-neck ratio was 1.81 +/- 0.55 and 1.55 +/- 0.48 for 2D DSA and 3DRA, respectively (P < .0001). When we defined "wide-neck" as a dome-to-neck ratio <1.5, sixty-nine (33.7%) aneurysms were wide-neck on 2D DSA compared with 119 (58%) on 3DRA (P < .0001). When we defined "wide-neck" as dome-to-neck ratio <2.0, one hundred forty-two (69.3%) aneurysms were wide-neck on 2D DSA compared with 173 (84.4%) on 3DRA (P = .0004). CONCLUSIONS: In this retrospective study, 3DRA measurements resulted in significantly lower dome-to-neck ratios and significantly larger proportions of aneurysms defined as "wide-neck" compared with 2D DSA. Scrutiny of 2D DSA may offer substantial benefit over 3D techniques when triaging patients to or from endovascular therapy.
BACKGROUND AND PURPOSE: Dome-to-neck ratio of intracranial aneurysms is an important predictor of outcomes of endovascular coiling. 3D imaging techniques are increasingly used in evaluating the dome-to-neck ratio of aneurysms for intervention. The purpose of this study was to determine whether 3D rotational angiography (3DRA) can be used to determine accurately the dome-to-neck ratio of intracranial aneurysms when compared with conventional 2D digital subtraction angiography (2D DSA). MATERIALS AND METHODS: A retrospective analysis of 180 patients with 205 intracranial aneurysms who underwent both 2D DSA and 3DRA for evaluation of previously untreated aneurysms was conducted. Dome-to-neck ratios were compared between 2D DSA and 3DRA images. The mean difference in dome-to-neck ratios between 2D DSA and 3DRA was calculated. The proportions of "wide-neck" aneurysms seen on 2D DSA and 3DRA were compared by using 2 different definitions of "wide-neck," including <1.5 and <2.0. RESULTS: The average dome-to-neck ratio was 1.81 +/- 0.55 and 1.55 +/- 0.48 for 2D DSA and 3DRA, respectively (P < .0001). When we defined "wide-neck" as a dome-to-neck ratio <1.5, sixty-nine (33.7%) aneurysms were wide-neck on 2D DSA compared with 119 (58%) on 3DRA (P < .0001). When we defined "wide-neck" as dome-to-neck ratio <2.0, one hundred forty-two (69.3%) aneurysms were wide-neck on 2D DSA compared with 173 (84.4%) on 3DRA (P = .0004). CONCLUSIONS: In this retrospective study, 3DRA measurements resulted in significantly lower dome-to-neck ratios and significantly larger proportions of aneurysms defined as "wide-neck" compared with 2D DSA. Scrutiny of 2D DSA may offer substantial benefit over 3D techniques when triaging patients to or from endovascular therapy.
Authors: R Yasuda; A Arat; C M Strother; B Aagaard-Kienitz; D Niemann; A Mohamed; K Royalty; K Pulfer; W Taki; M E Mawad Journal: AJNR Am J Neuroradiol Date: 2011-06-23 Impact factor: 3.825
Authors: J J Schneiders; H A Marquering; L Antiga; R van den Berg; E VanBavel; C B Majoie Journal: AJNR Am J Neuroradiol Date: 2012-08-16 Impact factor: 3.825