Literature DB >> 26907224

3D Surgical Printing Cutting Guides for Open-Wedge High Tibial Osteotomy: Do It Yourself.

Rubén Pérez-Mañanes1, Juan Arnal Burró1, Jose Rojo Manaute2, Francisco Chana Rodriguez1, Javier Vaquero Martín1.   

Abstract

Opening wedge osteotomy has recently gained popularity, thanks to the recent implementation of locking plates, which have shown equivalent stability with greater reproducibility, accuracy, and longevity than the closing wedge techniques and a lower prosthetic conversion rate. We present a new "do-it-yourself" cutting guides system for tibial opening osteotomy. Using a conventional computed tomography digital image, a positioning guide and wedge spacers were printed in three dimensions (3D) for implementing the osteotomy and obtaining the planned correction. The surgeon makes the whole process in a do-it-yourself style. This new technique was used in eight cases. Previous opening osteotomies with the standard technique were used as control (20 cases). Surgical time, fluoroscopic time, and accuracy of the axial correction were measured. The use of a custom positioning guide reduced the surgical (31 minutes less) and fluoroscopic times (6.9 times less) while achieving a high-axis correction accuracy compared with the standard technique. Digitally planned and executed osteotomies under 3D printed osteotomy positioning guides help the surgeon to minimize human error while reducing surgical time. The reproducibility of this technique is very robust, allowing a transfer of the steps planned in a virtual environment to the operating table. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2016        PMID: 26907224     DOI: 10.1055/s-0036-1572412

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  26 in total

1.  Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction.

Authors:  Lukas Jud; Philipp Fürnstahl; Lazaros Vlachopoulos; Tobias Götschi; Laura Catherine Leoty; Sandro F Fucentese
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-02-26       Impact factor: 4.342

2.  Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy.

Authors:  JianHui Shi; Wei Lv; Yan Wang; Ben Ma; Wei Cui; ZhenZhong Liu; KeCheng Han
Journal:  Int Orthop       Date:  2018-06-27       Impact factor: 3.075

3.  Application of a 3D custom printed patient specific spinal implant for C1/2 arthrodesis.

Authors:  Kevin Phan; Alessandro Sgro; Monish M Maharaj; Paul D'Urso; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2016-12

4.  Contralateral preoperative templating of lower limbs' mechanical angles is a reasonable option.

Authors:  Christophe Jacquet; Pierre Laumonerie; Sally LiArno; Ahmad Faizan; Akash Sharma; Louis Dagneaux; Matthieu Ollivier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-05-09       Impact factor: 4.342

5.  Early experience using patient-specific instrumentation in opening wedge high tibial osteotomy.

Authors:  Vlad Predescu; Alina-Maria Grosu; Iulian Gherman; Catalin Prescura; Valentin Hiohi; Bogdan Deleanu
Journal:  Int Orthop       Date:  2021-02-12       Impact factor: 3.075

6.  Patient-specific cutting guides for open-wedge high tibial osteotomy: safety and accuracy analysis of a hundred patients continuous cohort.

Authors:  Samir Chaouche; Christophe Jacquet; Maxime Fabre-Aubrespy; Akash Sharma; Jean-Noël Argenson; Sebastien Parratte; Matthieu Ollivier
Journal:  Int Orthop       Date:  2019-07-05       Impact factor: 3.075

7.  3D printing in experimental orthopaedic surgery: do it yourself.

Authors:  Irene I López-Torres; Pablo Sanz-Ruíz; Victor E León-Román; Federico Navarro-García; Rodrigo Priego-Sánchez; Javier Vaquero-Martín
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-03-12

8.  Double level knee osteotomy using patient-specific cutting guides is accurate and provides satisfactory clinical results: a prospective analysis of a cohort of twenty-two continuous patients.

Authors:  Francesco Grasso; Pierre Martz; Grégoire Micicoi; Raghbir Khakha; Kristian Kley; Lukas Hanak; Matthieu Ollivier; Christophe Jacquet
Journal:  Int Orthop       Date:  2021-09-18       Impact factor: 3.075

9.  More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy.

Authors:  Hee-June Kim; Jaeyeong Park; Ji-Yeon Shin; Il-Hyung Park; Kyeong-Hyeon Park; Hee-Soo Kyung
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-30       Impact factor: 4.342

10.  In-House, Fast FDM Prototyping of a Custom Cutting Guide for a Lower-Risk Pediatric Femoral Osteotomy.

Authors:  Leonardo Frizziero; Gian Maria Santi; Christian Leon-Cardenas; Giampiero Donnici; Alfredo Liverani; Paola Papaleo; Francesca Napolitano; Curzio Pagliari; Giovanni Luigi Di Gennaro; Stefano Stallone; Stefano Stilli; Giovanni Trisolino; Paola Zarantonello
Journal:  Bioengineering (Basel)       Date:  2021-05-26
View more