Literature DB >> 31273430

Patient-specific cutting guides for open-wedge high tibial osteotomy: safety and accuracy analysis of a hundred patients continuous cohort.

Samir Chaouche1,2, Christophe Jacquet1,2, Maxime Fabre-Aubrespy1,2, Akash Sharma1,2, Jean-Noël Argenson1,2, Sebastien Parratte1,2, Matthieu Ollivier3,4.   

Abstract

INTRODUCTION: Several recent studies have reported accurate and reliable use of patient-specific cutting guides (PSCG) for medial opening-wedge high tibial osteotomy (OW-HTO); however, a majority of these are small cases series or ex-vivo reports. The hypothesis of this study was that performing an OW-HTO with PSCG results in a reliable and accurate correction with good or satisfactory patient-reported functional outcomes at a mean of two years. We also hypothesized that the use of PSCG would not increase the rate of specific or non-specific complications.
METHODS: In this single-centre, observational study, a prospective cohort of a hundred patients (age < 60 years with isolated medial knee osteoarthritis and significant metaphyseal tibial vara) were included between February 2014 and November 2017 to investigate the safety and accuracy of OW-HTO using PSCG. The accuracy of post-operative alignment was defined by the difference between the desired correction defined pre-operatively and the correction obtained post-operatively measured on CT scan (ΔHKA, ΔMPTA, ΔPPTA). Functional outcomes were evaluated by the difference between the value obtained in the pre-operative questionnaire and that obtained at the last follow-up (mean 2 years) using the KOOS and UCLA activity scale. Intra-operative and post-operative complications were recorded.
RESULTS: The mean patient age was 44.17 ± 6.77 years; no patient was lost to follow-up at a mean of two years. The mean ΔHKA was 1 ± 0.95°, the mean ΔMPTA was 0.54 ± 0.63°, and the mean ΔPPTA was 0.43 ± 0.8°. No significant differences (all p values > 0.05) were observed between the desired correction defined pre-operatively and the correction obtained post-operatively (ΔHKA, ΔMPTA, ΔPPTA). An improvement of 27 ± 25 for the KOOS Pain, 28 ± 26 for the KOOS symptoms, 27 ± 28 for the KOOS ADL, 26 ± 33 for the KOOS sport/rec, 28 ± 38 for the KOOS QOL, and 2.6 ± 2.4 for the UCLA was obtained as compared with the pre-operative values (all p < 0.0001). No procedures observed were abandoned, and the PSCG was well positioned in all cases. The overall complication rate was 32% up to two years post-operatively, most of them being classed as minor events (28%).
CONCLUSION: Performing an OW-HTO with PSCG produces an accurate correction with good functional outcomes at a mean of two years. Furthermore, there is no increase in the rate of specific or non-specific complications. A study to assess the reproducibility of this technique, regardless of the surgical level, is needed.

Entities:  

Keywords:  Open-wedge tibial osteotomy; Osteotomy; Patient-specific cutting guides

Mesh:

Year:  2019        PMID: 31273430     DOI: 10.1007/s00264-019-04372-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  33 in total

Review 1.  Biomechanics of high tibial osteotomy.

Authors:  Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-07       Impact factor: 4.342

2.  Complications Associated With Medial Opening-Wedge High Tibial Osteotomy Using a Locking Plate: A Multicenter Study.

Authors:  Seung-Beom Han; Yong In; Kwang Jun Oh; Kwang Yun Song; Seok Tae Yun; Ki-Mo Jang
Journal:  J Arthroplasty       Date:  2018-11-14       Impact factor: 4.757

3.  Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum.

Authors:  Dominique Saragaglia; Jason Roberts
Journal:  Orthopedics       Date:  2005-10       Impact factor: 1.390

4.  Unicompartmental knee arthroplasty is superior to high tibial osteotomy in post-operative recovery and participation in recreational and sports activities.

Authors:  Man Soo Kim; In Jun Koh; Sueen Sohn; Ji Hwan Jeong; Yong In
Journal:  Int Orthop       Date:  2018-12-18       Impact factor: 3.075

Review 5.  How accurately does high tibial osteotomy correct the mechanical axis of an arthritic varus knee? A systematic review.

Authors:  Maxim Van den Bempt; Wouter Van Genechten; Toon Claes; Steven Claes
Journal:  Knee       Date:  2016-10-22       Impact factor: 2.199

Review 6.  The role of bone void fillers in medial opening wedge high tibial osteotomy: a systematic review.

Authors:  Omer Slevin; Olufemi R Ayeni; Stefan Hinterwimmer; Thomas Tischer; Matthias J Feucht; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-24       Impact factor: 4.342

7.  Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study.

Authors:  M Munier; M Donnez; M Ollivier; X Flecher; P Chabrand; J-N Argenson; S Parratte
Journal:  Orthop Traumatol Surg Res       Date:  2017-01-27       Impact factor: 2.256

8.  Medial open wedge vs. lateral closed wedge high tibial osteotomy - Indications based on the findings of patellar height, leg length, torsional correction and clinical outcome in one hundred cases.

Authors:  Felix Ferner; Christoph Lutter; Joerg Dickschas; Wolf Strecker
Journal:  Int Orthop       Date:  2018-10-24       Impact factor: 3.075

9.  Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement.

Authors:  S Schröter; C Ihle; D W Elson; S Döbele; U Stöckle; A Ateschrang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-22       Impact factor: 4.342

10.  The biomechanical effects of allograft wedges used for large corrections during medial opening wedge high tibial osteotomy.

Authors:  James Belsey; Arnaud Diffo Kaze; Simon Jobson; James Faulkner; Stefan Maas; Raghbir Khakha; Dietrich Pape; Adrian J Wilson
Journal:  PLoS One       Date:  2019-05-10       Impact factor: 3.240

View more
  14 in total

1.  Early experience using patient-specific instrumentation in opening wedge high tibial osteotomy.

Authors:  Vlad Predescu; Alina-Maria Grosu; Iulian Gherman; Catalin Prescura; Valentin Hiohi; Bogdan Deleanu
Journal:  Int Orthop       Date:  2021-02-12       Impact factor: 3.075

2.  [Effectiveness of intraoperative tibia fibular angle and femoral fibular angle in predicting coronal lower limb alignment after medial open-wedge high tibial osteotomy].

Authors:  Yanjie Mao; Axiang He; Ying Zhou; Yanan Chen; Yaru Liu; Xiaowei Yu; Xianlong Zhang; Wanjun Liu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-01-15

Review 3.  Consistent indications, targets and techniques for double-level osteotomy of the knee: a systematic review.

Authors:  Philippe Alves; Floris van Rooij; Thomas Kuratle; Mo Saffarini; Hermes Miozzari
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-03-15       Impact factor: 4.342

4.  Double level knee osteotomy using patient-specific cutting guides is accurate and provides satisfactory clinical results: a prospective analysis of a cohort of twenty-two continuous patients.

Authors:  Francesco Grasso; Pierre Martz; Grégoire Micicoi; Raghbir Khakha; Kristian Kley; Lukas Hanak; Matthieu Ollivier; Christophe Jacquet
Journal:  Int Orthop       Date:  2021-09-18       Impact factor: 3.075

5.  [Clinical application of split three-dimensional printing patient-specific instrumentation in medial open-wedge high tibial osteotomy].

Authors:  Fawei Gao; Chenggong Wang; Yihe Hu; Shilong Su; Jun Qi; Da Zhong
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-09-15

6.  3D printed fracture reduction guides planned and printed at the point of care show high accuracy - a porcine feasibility study.

Authors:  Andreas Hecker; Sophie C Eberlein; Frank M Klenke
Journal:  J Exp Orthop       Date:  2022-09-27

7.  Intra-articular opening wedge osteotomy for varus ankle arthritis with computer-assisted planning and patient-specific surgical guides: a retrospective case series.

Authors:  Xin-Long Ma; Jian-Xiong Ma; Xing-Wen Zhao; Yu-Ren Du; Ying Wang; Hao-Hao Bai; Bin Lu
Journal:  BMC Musculoskelet Disord       Date:  2022-05-21       Impact factor: 2.562

Review 8.  CAS and PSI increase coronal alignment accuracy and reduce outliers when compared to traditional technique of medial open wedge high tibial osteotomy: a meta-analysis.

Authors:  S Cerciello; M Ollivier; K Corona; B Kaocoglu; R Seil
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-09-10       Impact factor: 4.114

Review 9.  Revision ACL Reconstruction: Principles and Practice.

Authors:  Sachin Tapasvi; Anshu Shekhar
Journal:  Indian J Orthop       Date:  2021-01-19       Impact factor: 1.251

10.  CT based PSI blocks for osteotomies around the knee provide accurate results when intraoperative imaging is used.

Authors:  Peter Savov; Mara Hold; Maximilian Petri; Hauke Horstmann; Christian von Falck; Max Ettinger
Journal:  J Exp Orthop       Date:  2021-06-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.