Opportunities for improvement on current nuclear cardiology practices and radiation exposure in Latin America: Findings from the 65-country IAEA Nuclear Cardiology Protocols cross-sectional Study (INCAPS).

João V Vitola1, Fernando Mut2, Erick Alexánderson3, Thomas N B Pascual4, Mathew Mercuri5, Ganesan Karthikeyan6, Nathan Better7, Madan M Rehani8,9, Ravi Kashyap4, Maurizio Dondi4, Diana Paez4, Andrew J Einstein10,11.   

Abstract

BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND
RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus.
CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.

Entities:  

Keywords:  Latin America; Nuclear cardiology; PET; SPECT; best practices; radiation dose

Mesh:

Year:  2016        PMID: 26902484     DOI: 10.1007/s12350-016-0433-3

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  21 in total

1.  A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Anna Leykekhman; Linda B Thompson; Marvin Friedman
Journal:  J Nucl Cardiol       Date:  2011-02-02       Impact factor: 5.952

Review 2.  Assessing the need for nuclear cardiology and other advanced cardiac imaging modalities in the developing world.

Authors:  João V Vitola; Leslee J Shaw; Adel H Allam; Pilar Orellana; Amalia Peix; Annare Ellmann; Kevin C Allman; B N Lee; Chanika Siritara; Felix Y J Keng; Gianmario Sambuceti; Marla C Kiess; Raffaele Giubbini; Salaheddine E Bouyoucef; Zuo-Xiang He; Gregory S Thomas; Fernando Mut; Maurizio Dondi
Journal:  J Nucl Cardiol       Date:  2009-07-22       Impact factor: 5.952

3.  Global estimates of diabetes prevalence for 2013 and projections for 2035.

Authors:  L Guariguata; D R Whiting; I Hambleton; J Beagley; U Linnenkamp; J E Shaw
Journal:  Diabetes Res Clin Pract       Date:  2013-12-01       Impact factor: 5.602

4.  Radiation dose and prognosis of ultra-low-dose stress-first myocardial perfusion SPECT in patients with chest pain using a high-efficiency camera.

Authors:  Andrew J Einstein; Lynne L Johnson; Albert J DeLuca; Andrew C Kontak; Daniel W Groves; Jennifer Stant; Ted Pozniakoff; Bin Cheng; LeRoy E Rabbani; Sabahat Bokhari
Journal:  J Nucl Med       Date:  2015-03-05       Impact factor: 10.057

5.  Beyond the bombs: cancer risks of low-dose medical radiation.

Authors:  Andrew J Einstein
Journal:  Lancet       Date:  2012-06-07       Impact factor: 79.321

6.  Coronary heart disease and risk factors in latin america.

Authors:  Fernando Lanas; Pamela Serón; Alejandra Lanas
Journal:  Glob Heart       Date:  2013-12

7.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

Review 8.  Growing epidemic of coronary heart disease in low- and middle-income countries.

Authors:  Thomas A Gaziano; Asaf Bitton; Shuchi Anand; Shafika Abrahams-Gessel; Adrianna Murphy
Journal:  Curr Probl Cardiol       Date:  2010-02       Impact factor: 5.200

9.  Type 2 diabetes: an epidemic requiring global attention and urgent action.

Authors:  William H Herman; Paul Zimmet
Journal:  Diabetes Care       Date:  2012-05       Impact factor: 19.112

10.  Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).

Authors:  Andrew J Einstein; Thomas N B Pascual; Mathew Mercuri; Ganesan Karthikeyan; João V Vitola; John J Mahmarian; Nathan Better; Salah E Bouyoucef; Henry Hee-Seung Bom; Vikram Lele; V Peter C Magboo; Erick Alexánderson; Adel H Allam; Mouaz H Al-Mallah; Albert Flotats; Scott Jerome; Philipp A Kaufmann; Osnat Luxenburg; Leslee J Shaw; S Richard Underwood; Madan M Rehani; Ravi Kashyap; Diana Paez; Maurizio Dondi
Journal:  Eur Heart J       Date:  2015-04-21       Impact factor: 29.983

View more
  4 in total

1.  Cardiovascular PET/MR: "Not the end but the beginning".

Authors:  Thomas Hellmut Schindler
Journal:  J Nucl Cardiol       Date:  2017-01-26       Impact factor: 5.952

2.  A world view of nuclear cardiology practices: Think globally, act locally.

Authors:  Thomas A Holly
Journal:  J Nucl Cardiol       Date:  2016-02-25       Impact factor: 5.952

3.  Update of the Brazilian Guideline on Nuclear Cardiology - 2020.

Authors:  Luiz Eduardo Mastrocola; Barbara Juarez Amorim; João Vicente Vitola; Simone Cristina Soares Brandão; Gabriel Blacher Grossman; Ronaldo de Souza Leão Lima; Rafael Willain Lopes; William Azem Chalela; Lara Cristiane Terra Ferreira Carreira; José Roberto Nolasco de Araújo; Cláudio Tinoco Mesquita; José Claudio Meneghetti
Journal:  Arq Bras Cardiol       Date:  2020-02       Impact factor: 2.000

4.  Radiation exposure after myocardial perfusion imaging with Cadmium-Zinc-Telluride camera versus conventional camera.

Authors:  Ricardo Baumgarten; Rodrigo Julio Cerci; Amanda de Nadai Costa; Carlos Cunha Pereira-Neto; Pedro Prado; Marcello Zapparoli; Margaret Masukawa; Juliano Julio Cerci; João Vicente Vitola; Miguel Morita Fernandes-Silva
Journal:  J Nucl Cardiol       Date:  2020-05-14       Impact factor: 5.952