Contribution of PET Imaging to the Diagnosis of Septic Embolism in Patients With Pacing Lead Endocarditis.

Sana Amraoui1, Ghoufrane Tlili2, Manav Sohal3, Benjamin Berte4, Elif Hindié2, Philippe Ritter4, Sylvain Ploux4, Arnaud Denis4, Nicolas Derval4, Christopher A Rinaldi3, Charles Cazanave5, Pierre Jais4, Michel Haissaguerre4, Laurence Bordenave2, Pierre Bordachar4.   

Abstract

OBJECTIVES: The aim of this study was to investigate the role of 18-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) scanning in identifying septic embolism in patients with lead endocarditis.
BACKGROUND: Lead endocarditis may be associated with septic embolism, in which case the administration mode, type, and duration of antibiotic therapy must be adapted. However, diagnosis can be challenging: magnetic resonance imaging (MRI) cannot be performed in the vast majority of patients with cardiac implantable electronic devices (CIEDs). FDG PET/CT scanning has been proposed as a diagnostic tool for suspected CIED infection.
METHODS: Thirty-five consecutive patients with lead endocarditis were prospectively studied. FDG PET/CT scanning was performed and analyzed blindly by experienced nuclear medicine physicians to assess for the presence of septic embolism 2 days before lead extraction.
RESULTS: FDG PET/CT scanning identified septic emboli in 10 patients (29%): 7 with spondylodiscitis, 2 with septic pulmonary emboli, and 1 with an infected vascular prosthesis. Among the 7 patients with occult spondylodiscitis, 4 were asymptomatic, and 3 had back pain with negative CT imaging, MRI being contraindicated due to non MRI-compatible CIEDs. Antimicrobial therapy was adapted (double antibiotic therapy with good bone penetration) and prolonged. Among other important ancillary findings, 3 patients presented focal FDG uptake in the colon (1 adenocarcinoma, and 2 resected polyps) and 2 in the esophagus (both cases confirmed as neoplasia).
CONCLUSIONS: This study emphasizes the potential utility of FDG PET/CT scanning as a diagnostic tool for septic emboli in patients with pacing lead endocarditis. This promising diagnostic tool may be integrated in the diagnostic algorithm of patients with lead endocarditis because diagnosis of septic embolisms has a direct and significant impact on the therapeutic care pathway.
Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  FDG PET/CT scanning; lead endocarditis; pacemaker infection; septic emboli; spondylodiscitis

Mesh:

Substances:

Year:  2016        PMID: 26897683     DOI: 10.1016/j.jcmg.2015.09.014

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  17 in total

1.  Recommendations on nuclear and multimodality imaging in IE and CIED infections.

Authors:  Paola Anna Erba; Patrizio Lancellotti; Isidre Vilacosta; Oliver Gaemperli; Francois Rouzet; Marcus Hacker; Alberto Signore; Riemer H J A Slart; Gilbert Habib
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-05-24       Impact factor: 9.236

Review 2.  Transvenous Lead Extractions: Current Approaches and Future Trends.

Authors:  Adryan A Perez; Frank W Woo; Darren C Tsang; Roger G Carrillo
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

3.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

4.  Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study.

Authors:  Igor Diemberger; Rachele Bonfiglioli; Cristian Martignani; Maddalena Graziosi; Mauro Biffi; Stefano Lorenzetti; Matteo Ziacchi; Cristina Nanni; Stefano Fanti; Giuseppe Boriani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-08       Impact factor: 9.236

Review 5.  Accuracy of Positron Emission Tomography as a Diagnostic Tool for Lead Endocarditis: Design of the Prospective Multicentre ENDOTEP Study.

Authors:  Sana Amraoui; Ghoufrane Tlili; Elif Hindié; Paul Perez; Olivia Peuchant; Laurence Bordenave; Pierre Bordachar
Journal:  Eur Cardiol       Date:  2016-08

6.  Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.

Authors:  Sana Amraoui; Ghoufrane Tlili; Manav Sohal; Laurence Bordenave; Pierre Bordachar
Journal:  J Nucl Cardiol       Date:  2016-05-05       Impact factor: 5.952

7.  Management of Cardiac Electronic Device Infections: Challenges and Outcomes.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Jens Cosedis Nielsen
Journal:  Arrhythm Electrophysiol Rev       Date:  2016

Review 8.  Cardiac Imaging of Infective Endocarditis, Echo and Beyond.

Authors:  Bernard Iung; François Rouzet; Eric Brochet; Xavier Duval
Journal:  Curr Infect Dis Rep       Date:  2017-02       Impact factor: 3.725

Review 9.  State-of-the-art narrative review: multimodality imaging in electrophysiology and cardiac device therapies.

Authors:  Balint Laczay; Divyang Patel; Richard Grimm; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

10.  Update of the Brazilian Guideline on Nuclear Cardiology - 2020.

Authors:  Luiz Eduardo Mastrocola; Barbara Juarez Amorim; João Vicente Vitola; Simone Cristina Soares Brandão; Gabriel Blacher Grossman; Ronaldo de Souza Leão Lima; Rafael Willain Lopes; William Azem Chalela; Lara Cristiane Terra Ferreira Carreira; José Roberto Nolasco de Araújo; Cláudio Tinoco Mesquita; José Claudio Meneghetti
Journal:  Arq Bras Cardiol       Date:  2020-02       Impact factor: 2.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.