Literature DB >> 26896792

Hetero-enzyme-based two-round signal amplification strategy for trace detection of aflatoxin B1 using an electrochemical aptasensor.

Wanli Zheng1, Jun Teng1, Lin Cheng1, Yingwang Ye1, Daodong Pan1, Jingjing Wu1, Feng Xue2, Guodong Liu3, Wei Chen4.   

Abstract

An electrochemical aptasensor for trace detection of aflatoxin B1 (AFB1) was developed by using an aptamer as the recognition unit while adopting the telomerase and EXO III based two-round signal amplification strategy as the signal enhancement units. The telomerase amplification was used to elongate the ssDNA probes on the surface of gold nanoparticles, by which the signal response range of the signal-off model electrochemical aptasensor could be correspondingly enlarged. Then, the EXO III amplification was used to hydrolyze the 3'-end of the dsDNA after the recognition of target AFB1, which caused the release of bounded AFB1 into the sensing system, where it participated in the next recognition-sensing cycle. With this two-round signal amplified electrochemical aptasensor, target AFB1 was successfully measured at trace concentrations with excellent detection limit of 0.6*10(-4)ppt and satisfied specificity due to the excellent affinity of the aptamer against AFB1. Based on this designed two-round signal amplification strategy, both the sensing range and detection limit were greatly improved. This proposed ultrasensitive electrochemical aptasensor method was also validated by comparison with the classic instrumental methods. Importantly, this hetero-enzyme based two-round signal amplified electrochemical aptasensor offers a great promising protocol for ultrasensitive detection of AFB1 and other mycotoxins by replacing the core recognition sequence of the aptamer.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aflatoxin B1; Aptasensor; Electrochemical; Gold nanoparticle; Signal amplification

Mesh:

Substances:

Year:  2016        PMID: 26896792     DOI: 10.1016/j.bios.2016.01.091

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  Impedimetric determination of Staphylococcal enterotoxin B using electrochemical switching with DNA triangular pyramid frustum nanostructure.

Authors:  Xiaoye Chen; Xinping Shi; Yun Liu; Lixia Lu; Yichen Lu; Xiong Xiong; Yuanjian Liu; Xiaohui Xiong
Journal:  Mikrochim Acta       Date:  2018-09-15       Impact factor: 5.833

Review 2.  A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials.

Authors:  K Yugender Goud; K Koteshwara Reddy; M Satyanarayana; Shekher Kummari; K Vengatajalabathy Gobi
Journal:  Mikrochim Acta       Date:  2019-12-07       Impact factor: 5.833

3.  An electrochemical aptasensor based on target triggered multiple-channel DNAzymes cycling amplification strategy with PtFe@Co-MOF as signal amplifier.

Authors:  Tong Zhu; Na Li; Jiangjian Huang; Xiaohansi Xu; Xin Su; Yi Ma; Renxiang Yang; Jia Ruan; Huilan Su
Journal:  Mikrochim Acta       Date:  2022-09-21       Impact factor: 6.408

Review 4.  Noble metal nanomaterial-based aptasensors for microbial toxin detection.

Authors:  Yue He; Cong-Ying Wen; Zhi-Jun Guo; Yu-Fen Huang
Journal:  J Food Drug Anal       Date:  2020-12-15       Impact factor: 6.157

Review 5.  Nano-Aptasensing in Mycotoxin Analysis: Recent Updates and Progress.

Authors:  Amina Rhouati; Gonca Bulbul; Usman Latif; Akhtar Hayat; Zhan-Hong Li; Jean Louis Marty
Journal:  Toxins (Basel)       Date:  2017-10-28       Impact factor: 4.546

Review 6.  Recent Advances in the Aptamer-Based Electrochemical Biosensors for Detecting Aflatoxin B1 and Its Pertinent Metabolite Aflatoxin M1.

Authors:  Hadi Beitollahi; Somayeh Tajik; Zahra Dourandish; Kaiqiang Zhang; Quyet Van Le; Ho Won Jang; Soo Young Kim; Mohammadreza Shokouhimehr
Journal:  Sensors (Basel)       Date:  2020-06-08       Impact factor: 3.576

7.  Rapid and simultaneous visual screening of SARS-CoV-2 and influenza virufses with customized isothermal amplification integrated lateral flow strip.

Authors:  Yong Sun; Panzhu Qin; Jun He; Weiwei Li; Yonglin Shi; Jianguo Xu; Qian Wu; Qingqing Chen; Weidong Li; Xinxin Wang; Guodong Liu; Wei Chen
Journal:  Biosens Bioelectron       Date:  2021-11-06       Impact factor: 10.618

Review 8.  Ensuring food safety using aptamer based assays: Electroanalytical approach.

Authors:  Hedieh Malekzad; Abolghasem Jouyban; Mohammad Hasanzadeh; Nasrin Shadjou; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2017-07-10       Impact factor: 12.296

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.