Literature DB >> 26890732

Targeted Lesion Generation Through the Skull Without Aberration Correction Using Histotripsy.

Jonathan Sukovich, Zhen Xu, Yohan Kim, Hui Cao, Thai-Son Nguyen, Aditya Pandey, Timothy Hall, Charles Cain.   

Abstract

This study demonstrates the ability of histotripsy to generate targeted lesions through the skullcap without using aberration correction. Histotripsy therapy was delivered using a 500 kHz, 256-element hemispherical transducer with an aperture diameter of 30 cm and a focal distance of 15 cm fabricated in our lab. This transducer is theoretically capable of producing peak rarefactional pressures, based on linear estimation, (p-)LE, in the free field in excess of 200MPa with pulse durations 2 acoustic cycles. Three excised human skullcaps were used displaying attenuations of 73-81% of the acoustic pressure without aberration correction. Through all three skullcaps, compact lesions with radii less than 1mm were generated in red blood cell (RBC) agarose tissue phantoms without aberration correction, using estimated (p-)LE of 28-39MPa, a pulse repetition frequency of 1Hz, and a total number of 300 pulses. Lesion generation was consistently observed at the geometric focus of the transducer as the position of the skullcap with respect to the transducer was varied, and multiple patterned lesions were generated transcranially by mechanically adjusting the position of the skullcap with respect to the transducer to target different regions within. These results show that compact, targeted lesions with sharp boundaries can be generated through intact skullcaps using histotripsy with very short pulses without using aberration correction. Such capability has the potential to greatly simplify transcranial ultrasound therapy for non-invasive transcranial applications, as current ultrasound transcranial therapy techniques all require sophisticated aberration correction.

Entities:  

Year:  2016        PMID: 26890732     DOI: 10.1109/TUFFC.2016.2531504

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  17 in total

Review 1.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

2.  Novel acoustic coupling bath using magnetite nanoparticles for MR-guided transcranial focused ultrasound surgery.

Authors:  Steven P Allen; Tom Steeves; Austin Fergusson; Dave Moore; Richey M Davis; Eli Vlaisialjevich; Craig H Meyer
Journal:  Med Phys       Date:  2019-10-29       Impact factor: 4.071

3.  Histotripsy Ablation of Bone Tumors: Feasibility Study in Excised Canine Osteosarcoma Tumors.

Authors:  Lauren Arnold; Alissa Hendricks-Wenger; Sheryl Coutermarsh-Ott; Jessica Gannon; Alayna N Hay; Nikolaos Dervisis; Shawna Klahn; Irving C Allen; Joanne Tuohy; Eli Vlaisavljevich
Journal:  Ultrasound Med Biol       Date:  2021-08-27       Impact factor: 3.694

4.  Two-step aberration correction: application to transcranial histotripsy.

Authors:  Ning Lu; Timothy L Hall; Jonathan R Sukovich; Sang Won Choi; John Snell; Nathan McDannold; Zhen Xu
Journal:  Phys Med Biol       Date:  2022-06-10       Impact factor: 4.174

5.  In vivo histotripsy brain treatment.

Authors:  Jonathan R Sukovich; Charles A Cain; Aditya S Pandey; Neeraj Chaudhary; Sandra Camelo-Piragua; Steven P Allen; Timothy L Hall; John Snell; Zhiyuan Xu; Jonathan M Cannata; Dejan Teofilovic; James A Bertolina; Neal Kassell; Zhen Xu
Journal:  J Neurosurg       Date:  2018-10-01       Impact factor: 5.115

6.  Soft-Tissue Aberration Correction for Histotripsy.

Authors:  Jonathan J Macoskey; Timothy L Hall; Jonathan R Sukovich; Sang Won Choi; Kimberly Ives; Eric Johnsen; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

7.  The influence of medium elasticity on the prediction of histotripsy-induced bubble expansion and erythrocyte viability.

Authors:  Kenneth B Bader
Journal:  Phys Med Biol       Date:  2018-05-02       Impact factor: 3.609

8.  Stereotactic Transcranial Focused Ultrasound Targeting System for Murine Brain Models.

Authors:  Sang Won Choi; Tyler I Gerhardson; Sarah E Duclos; Rachel K Surowiec; Ulrich M Scheven; Stefanie Galban; Fred T Lee; Joan M Greve; James M Balter; Timothy L Hall; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

9.  Catheter Hydrophone Aberration Correction for Transcranial Histotripsy Treatment of Intracerebral Hemorrhage: Proof-of-Concept.

Authors:  Tyler Gerhardson; Jonathan R Sukovich; Aditya S Pandey; Timothy L Hall; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-31       Impact factor: 2.725

10.  Real-Time Transcranial Histotripsy Treatment Localization and Mapping Using Acoustic Cavitation Emission Feedback.

Authors:  Jonathan R Sukovich; Jonathan J Macoskey; Jonathan E Lundt; Tyler I Gerhardson; Timothy L Hall; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-01-17       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.