Abstract

PURPOSE: To investigate the effects of the duration of contact lens (CL) wear on the meibomian glands (MGs), eyelid and tear film.
METHODS: This was a cross-sectional study of CL wearers and non-wearers (NWs) aged between 18 and 35 years. The sample comprised of: (i) Three groups of CL wearers of different duration profiles (short, moderate and long experience of CL wear); (ii) a group of previous CL wearers (PWs) who had ceased wear for at least 6 months prior to the present study; (iii) healthy non-wearers as a control group. Study procedures were conducted in the order from least invasive to most invasive as follows: symptom assessment, lipid assessment, non-invasive break-up time, tear meniscus area, tear osmolarity and evaporation, Phenol red thread, MG expressibility, ocular surface and eyelid assessments, meibography, Marx line and lid wiper assessment using lissamine green. For statistical comparison of continuous data, one-way analysis of variance was used with Bonferroni post-hoc correction, where appropriate. Kruskal-Wallis test and Pearson Chi-Square respectively were used for ordinal and categorical variables.
RESULTS: A total of 100 participants (49 males and 51 females; mean age ± SD: 25.4 ± 4.1) were enrolled across the five groups, such that each was composed of 20 age/sex matched individuals. Significant differences between the study groups were found for MG expressibility (p < 0.001), number of plugged orifices (p = 0.001), number of expressed orifices (p < 0.001), MG dropout (p = 0.001), Marx line score (p < 0.001), palpebral redness (p = 0.003), and roughness (p = 0.002), non-invasive break-up time (p < 0.001), Phenol red thread (p = 0.005), and tear meniscus area (p = 0.029). For all these variables, the NW group was statistically different from all other groups. Duration of wear was not a significant factor, except for Marx line score which was different in PWs compared to those with longer experience of CL wear (p = 0.03)
CONCLUSION: Alterations to MG morphology and function accompany contact lens wear. Although these changes onset during the first 2 years of wear, prolonged CL exposure beyond this point does not appear to be associated with further modification. Cessation of wear for at up to 6 months does not lead to resolution.
© 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

Entities:  

Keywords:  Marx's line; contact lens; dry eye; lid margin; meibomian glands; tear film

Mesh:

Year:  2016        PMID: 26890701     DOI: 10.1111/opo.12278

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  12 in total

Review 1.  TFOS DEWS II Tear Film Report.

Authors:  Mark D P Willcox; Pablo Argüeso; Georgi A Georgiev; Juha M Holopainen; Gordon W Laurie; Tom J Millar; Eric B Papas; Jannick P Rolland; Tannin A Schmidt; Ulrike Stahl; Tatiana Suarez; Lakshman N Subbaraman; Omür Ö Uçakhan; Lyndon Jones
Journal:  Ocul Surf       Date:  2017-07-20       Impact factor: 5.033

2.  Expression Profiling of Nonpolar Lipids in Meibum From Patients With Dry Eye: A Pilot Study.

Authors:  Jianzhong Chen; Jeremy K Keirsey; Kari B Green; Kelly K Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-04-01       Impact factor: 4.799

3.  Risk factors for severe Meibomian gland atrophy in a young adult population: A cross-sectional study.

Authors:  Thao N Yeh; Meng C Lin
Journal:  PLoS One       Date:  2017-09-28       Impact factor: 3.240

Review 4.  Contact lens wear and dry eyes: challenges and solutions.

Authors:  Maria Markoulli; Sailesh Kolanu
Journal:  Clin Optom (Auckl)       Date:  2017-02-15

5.  Microfluidic Contact Lenses.

Authors:  Nan Jiang; Yunuen Montelongo; Haider Butt; Ali K Yetisen
Journal:  Small       Date:  2018-03-09       Impact factor: 13.281

6.  Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers.

Authors:  Tianpu Gu; Lu Zhao; Zhuzhu Liu; Shaozhen Zhao; Hong Nian; Ruihua Wei
Journal:  BMC Ophthalmol       Date:  2020-03-04       Impact factor: 2.209

Review 7.  Meibomian Gland Disease: The Role of Gland Dysfunction in Dry Eye Disease.

Authors:  Priyanka Chhadva; Raquel Goldhardt; Anat Galor
Journal:  Ophthalmology       Date:  2017-11       Impact factor: 14.277

8.  A single vectored thermal pulsation treatment for meibomian gland dysfunction increases mean comfortable contact lens wearing time by approximately 4 hours per day.

Authors:  Caroline A Blackie; Christy A Coleman; Kelly K Nichols; Lyndon Jones; Peter Q Chen; Ron Melton; David L Kading; Leslie E O'Dell; Sruthi Srinivasan
Journal:  Clin Ophthalmol       Date:  2018-01-17

9.  An Eyelid Warming Device for the Management of Meibomian Gland Dysfunction.

Authors:  William Ngo; Sruthi Srinivasan; Lyndon Jones
Journal:  J Optom       Date:  2018-10-16

10.  Evaluation of the meibomian glands using the tear interferometer wearing orthokeratology lenses.

Authors:  Jiyoung Lee; Gyudeok Hwang; Minji Ha; Hyun-Seung Kim; Kyungdo Han; Kyung-Sun Na
Journal:  BMC Ophthalmol       Date:  2022-03-24       Impact factor: 2.209

View more