Literature DB >> 26887564

Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects.

Vipul Bhandari1, Jagdeesh K Reddy2, Kirti Relekar2, Ameya Ingawale2, Neeraj Shah2.   

Abstract

The aim of the study is to investigate the applicability of a newly developed corneal topographer in assessing tear film stability in Indian subjects. A prospective comparative study of 25 Indian subjects with dry eyes attending a tertiary eye care clinic in South India and 25 normal control subjects was conducted. The diagnosis of dry eye was made based on ocular surface disease index questionnaire. Non-invasive tear film break-up time (NI-TBUT) was measured using a new method based on a corneal topographer equipped with modified scan software. The correlations between the NI-TBUT and the traditional fluorescein tear film break-up time (F-TBUT), Schirmer I test values were determined. A total of 50 patients (100 eyes) were included. The values of NI-TBUT were significantly lower than the values of F-TBUT in both the cases (NI-TBUT 5.78 ± 0.8 s and F-TBUT 7.56 ± 0.5 s; p < 0.02) and controls (NI-TBUT 11.66 ± 1 s and F-TBUT 12.92 ± 1.2 s; p < 0.01). NI-TBUT values were significantly lower than the corresponding F-TBUT values in the varying grades of dry eyes. The mean NI-TBUT values in mild dry eyes was 6.42 ± 0.2 s, moderate dry eyes was 4.70 ± 0.3 s and in severe dry eyes was 2.32 ± 1.2 s. There was a significant difference in the NI-TBUT values for cases and controls (p < 0.001). There was a good correlation seen between the NI-TBUT values and the F-TBUT values, Schirmer I values and the ODSI scores. NI-TBUT was found to have a sensitivity of 86.1 % and a specificity of 81.1 % when the cut-off value was kept at 6.2 s. We investigated the performance of a non-invasive technique for measuring tear film stability to aid in the diagnosis of dry eye disease. It is a useful non-invasive objective method for the detection of dry eye, and its varying grades and may be useful in monitoring the efficacy of therapies for dry eye.

Entities:  

Keywords:  Corneal topographer; Indian; Non-invasive; TBUT

Mesh:

Year:  2016        PMID: 26887564     DOI: 10.1007/s10792-016-0186-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  36 in total

1.  A new method for tear film stability analysis using videokeratography.

Authors:  Tomoko Goto; Xiaodong Zheng; Stephen D Klyce; Hisashi Kataoka; Toshihiko Uno; Mike Karon; Yoshiyuki Tatematsu; Takeo Bessyo; Kazuo Tsubota; Yuichi Ohashi
Journal:  Am J Ophthalmol       Date:  2003-05       Impact factor: 5.258

2.  Clinical evaluation of the Oculus Keratograph.

Authors:  N Best; L Drury; J S Wolffsohn
Journal:  Cont Lens Anterior Eye       Date:  2012-04-28       Impact factor: 3.077

Review 3.  Future directions in non-invasive measurements of tear film surface kinetics.

Authors:  Dorota H Szczesna-Iskander; D Robert Iskander
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

4.  Factors affecting tear film breakup in normal eyes.

Authors:  M A Lemp; J R Hamill
Journal:  Arch Ophthalmol       Date:  1973-02

5.  Effect of fluorescein instillation on the pre-corneal tear film stability.

Authors:  L S Mengher; A J Bron; S R Tonge; D J Gilbert
Journal:  Curr Eye Res       Date:  1985-01       Impact factor: 2.424

6.  The relation between invasive and noninvasive tear break-up time.

Authors:  P Cho; W Douthwaite
Journal:  Optom Vis Sci       Date:  1995-01       Impact factor: 1.973

7.  Reliability of a portable noninvasive tear break-up time test on Hong Kong-Chinese.

Authors:  P Cho
Journal:  Optom Vis Sci       Date:  1993-12       Impact factor: 1.973

8.  Effect of fluorescein on the tear stability of Hong Kong-Chinese.

Authors:  P Cho; B Brown; C Lau
Journal:  Optom Vis Sci       Date:  1996-01       Impact factor: 1.973

9.  A simple approach to the repeatability of the Schirmer test without anesthesia: eyes open or closed?

Authors:  Didem Serin; Safak Karsloğlu; Aysu Kyan; Gürsoy Alagöz
Journal:  Cornea       Date:  2007-09       Impact factor: 2.651

10.  Assessment of tear film stability in dry eye with a newly developed keratograph.

Authors:  Jiaxu Hong; Xinghuai Sun; Anji Wei; Xinhan Cui; Yimin Li; Tingting Qian; Wentao Wang; Jianjiang Xu
Journal:  Cornea       Date:  2013-05       Impact factor: 2.651

View more
  2 in total

1.  Agreement and repeatability of objective systems for assessment of the tear film.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; Javier García-Montesinos; David P Piñero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-04-18       Impact factor: 3.117

2.  Smart Eye Camera: A Validation Study for Evaluating the Tear Film Breakup Time in Human Subjects.

Authors:  Eisuke Shimizu; Hiroyuki Yazu; Naohiko Aketa; Ryota Yokoiwa; Shinri Sato; Taiichiro Katayama; Akiko Hanyuda; Yasunori Sato; Yoko Ogawa; Kazuo Tsubota
Journal:  Transl Vis Sci Technol       Date:  2021-04-01       Impact factor: 3.283

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.