Literature DB >> 12719066

A new method for tear film stability analysis using videokeratography.

Tomoko Goto1, Xiaodong Zheng, Stephen D Klyce, Hisashi Kataoka, Toshihiko Uno, Mike Karon, Yoshiyuki Tatematsu, Takeo Bessyo, Kazuo Tsubota, Yuichi Ohashi.   

Abstract

PURPOSE: To report a new tear film stability analysis system using videokeratography.
DESIGN: Observational case series.
METHODS: New videokeratography software for TMS-2N (topographic modeling system; TOMEY Corporation, Nagoya, Japan) was developed that can automatically capture consecutive corneal surface images every second for 10 seconds. Forty-eight adult volunteers (80 eyes) were recruited for this study, and all subjects were examined with the new system. Corneal topographs were analyzed for tear breakup time (TMS-BUT) and the ratio of breakup area to entire color-code area (TMS-BUA) was calculated. Routine methods for tear film breakup time evaluation using slit-lamp microscope and fluorescence staining (SLE-BUT) were performed for comparison purposes. Regressive correlations of TMS-BUT or TMS-BUA with SLE-BUT were analyzed. Based on SLE results, subjects were separated into two groups with normal and short BUT, respectively. TMS-BUT and TMS-BUA were compared with SLE-BUT data with regard to the sensitivity and specificity of evaluation of dry eye symptoms.
RESULTS: Topographic modeling system-tear breakup time (TMS-BUT) had a positive correlation with SLE-BUT (R = 0.7219, P <.0001), whereas TMS-BUA showed a negative correlation (R = 0.6317, P <.0001). Among 34 eyes with normal SLE-BUT, 11 eyes (32.35%) displayed abnormal TMS-BUT, 9 (81.82%) of which were associated with dry eye symptoms. The sensitivities of TMS-BUT and TMS-BUA were 97.5% and 95%, respectively, significantly higher than that of SLE-BUT (75%), with P =.008 and 0.01, respectively. Topographic modeling system-BUT and TMS-BUA displayed a similar rate of specificity in comparison with SLE-BUT.
CONCLUSIONS: This new videokeratography system is a noninvasive and objective method with increased sensitivity for tear film stability analysis.

Entities:  

Mesh:

Year:  2003        PMID: 12719066     DOI: 10.1016/s0002-9394(02)02221-3

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  22 in total

Review 1.  [Dry eye. An update on epidemiology, diagnosis, therapy and new concepts].

Authors:  F Schirra; K W Ruprecht
Journal:  Ophthalmologe       Date:  2004-01       Impact factor: 1.059

2.  Tear film break-up time evaluated by real-time Hartmann-Shack wavefront sensing.

Authors:  Toshifumi Mihashi; Yoko Hirohara; Shizuka Koh; Sayuri Ninomiya; Naoyuki Maeda; Takashi Fujikado
Journal:  Jpn J Ophthalmol       Date:  2006 Mar-Apr       Impact factor: 2.447

3.  Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics.

Authors:  Yoko Hirohara; Toshifumi Mihashi; Shizuka Koh; Sayuri Ninomiya; Naoyuki Maeda; Takashi Fujikado
Journal:  Jpn J Ophthalmol       Date:  2007-08-03       Impact factor: 2.447

4.  Measurement of the time course of optical quality and visual deterioration during tear break-up.

Authors:  Haixia Liu; Larry Thibos; Carolyn G Begley; Arthur Bradley
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-01-27       Impact factor: 4.799

5.  Association between clinical diagnostic tests and health-related quality of life surveys in patients with dry eye syndrome.

Authors:  Yoshinobu Mizuno; Masakazu Yamada; Yozo Miyake
Journal:  Jpn J Ophthalmol       Date:  2010-08-11       Impact factor: 2.447

Review 6.  Mechanisms, imaging and structure of tear film breakup.

Authors:  P Ewen King-Smith; Carolyn G Begley; Richard J Braun
Journal:  Ocul Surf       Date:  2017-09-20       Impact factor: 5.033

7.  Relationships among Tear Film Stability, Osmolarity, and Dryness Symptoms.

Authors:  Thao N Yeh; Andrew D Graham; Meng C Lin
Journal:  Optom Vis Sci       Date:  2015-09       Impact factor: 1.973

8.  Tear cytokine and chemokine analysis and clinical correlations in evaporative-type dry eye disease.

Authors:  Amalia Enríquez-de-Salamanca; Evangelina Castellanos; Michael E Stern; Itziar Fernández; Ester Carreño; Carmen García-Vázquez; Jose M Herreras; Margarita Calonge
Journal:  Mol Vis       Date:  2010-05-19       Impact factor: 2.367

9.  Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects.

Authors:  Vipul Bhandari; Jagdeesh K Reddy; Kirti Relekar; Ameya Ingawale; Neeraj Shah
Journal:  Int Ophthalmol       Date:  2016-02-18       Impact factor: 2.031

10.  An Automated Grading and Diagnosis System for Evaluation of Dry Eye Syndrome.

Authors:  Ayşe Bağbaba; Baha Şen; Dursun Delen; Betül Seher Uysal
Journal:  J Med Syst       Date:  2018-10-08       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.