Matthew D Solomon1,2,3, Jingrong Yang4, Sue Hee Sung4, Martha L Livingston5, George Sarlas5, Judith C Lenane5, Alan S Go4,6,7.
Abstract
BACKGROUND: Ambulatory electrocardiographic (ECG) monitoring is the standard to screen for high-risk arrhythmias. We evaluated the clinical utility of a novel, leadless electrode, single-patient-use ECG monitor that stores up to 14 days of a continuous recording to measure the burden and timing of potentially high-risk arrhythmias.Entities:
Mesh:
Year: 2016 PMID: 26883019 PMCID: PMC4756401 DOI: 10.1186/s12872-016-0210-x
Source DB: PubMed Journal: BMC Cardiovasc Disord ISSN: 1471-2261 Impact factor: 2.298
Fig. 1Cohort assembly
Characteristics of 122,815 eligible continuous ambulatory ECG monitoring records between November 2011 and December 2013
| Characteristics | Overall | Non-sustained ventricular tachycardia | Sustained ventricular tachycardia | Sinus pause | Atrial fibrillation pause | Symptomatic pause | High-grade heart blocka |
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
| |
| Age, years, N (%) | |||||||
| < 65 | 61,170 (49.8) | 7,787 (34.7) | 102 (42.9) | 497 (28.1) | 88 (16.9) | 60 (24.1) | 481 (32.8) |
| 65–79 | 42,469 (34.6) | 9,596 (42.8) | 102 (42.9) | 735 (41.6) | 272 (52.2) | 133 (53.4) | 582 (39.7) |
| ≥ 80 | 19,176 (15.6) | 5,060 (22.6) | 34 (14.3) | 534 (30.2) | 161 (30.9) | 56 (22.5) | 405 (27.6) |
| Women, N (%) | 65,081 (53.0) | 8,316 (37.1) | 59 (24.8) | 698 (39.5) | 238 (45.7) | 131 (52.6) | 571 (38.9) |
| Wear Days | |||||||
| Mean (Standard Deviation) | 9.6 (4.0) | 10.8 (3.5) | 10.7 (3.4) | 10.7 (3.7) | 11.1 (3.4) | 10.9 (3.5) | 10.4 (3.7) |
| Median (IQR) | 9.9 (6.8–13.8) | 12.9 (7.1–13.9) | 12.1 (7.1–13.9) | 12.9 (7.0–14.0) | 13.0 (7.3–14.0) | 12.9 (7.1–14.0) | 12.1 (7.0–13.9) |
| Analyzable Days | |||||||
| Mean (Standard Deviation) | 9.2 (3.9) | 10.4 (3.5) | 10.1 (3.4) | 10.2 (3.7) | 10.5 (3.3) | 10.3 (3.4) | 9.9 (3.7) |
| Median (IQR) | 9.1 (6.4–13.1) | 11.8 (7.0–13.6) | 11.3 (6.9–13.4) | 11.8 (6.9–13.6) | 12.1 (7.1–13.6) | 11.7 (7.0–13.5) | 10.9 (6.8–13.5) |
aIncluded Mobitz II heart block and third-degree heart block
Fig. 2Cumulative Yield of Sustained and Non-sustained Ventricular Tachycardia. Data are shown for the overall population of patients with the arrhythmia and stratified by age and gender
Fig. 3Cumulative yield of pauses and high grade heart block. Data are shown for the overall population of patients with the arrhythmia and stratified by age and gender. AF = atrial fibrillation