Literature DB >> 23672988

Diagnostic utility of a novel leadless arrhythmia monitoring device.

Mintu P Turakhia1, Donald D Hoang, Peter Zimetbaum, Jared D Miller, Victor F Froelicher, Uday N Kumar, Xiangyan Xu, Felix Yang, Paul A Heidenreich.   

Abstract

Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23672988     DOI: 10.1016/j.amjcard.2013.04.017

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  49 in total

Review 1.  Digital health solutions in the screening of subclinical atrial fibrillation.

Authors:  Sebastian König; Andreas Bollmann; Gerhard Hindricks
Journal:  Herz       Date:  2021-06-04       Impact factor: 1.443

2.  [A DenseNet-based diagnosis algorithm for automated diagnosis using clinical ECG data].

Authors:  Jiewei Lai; Yundai Chen; Baoshi Han; Lei Ji; Yajun Shi; Zhicong Huang; Wei Yang; Qianjin Feng
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-01-30

3.  Optimal configuration of adhesive ECG patches suitable for long-term monitoring of a vectorcardiogram.

Authors:  Muammar M Kabir; Erick A Perez-Alday; Jason Thomas; Golriz Sedaghat; Larisa G Tereshchenko
Journal:  J Electrocardiol       Date:  2016-12-29       Impact factor: 1.438

4.  AF Detected on Implanted Cardiac Implantable Electronic Devices: Is There a Threshold for Thromboembolic Risk?

Authors:  Motaz Baibars; Khalil Kanjwal; Joseph E Marine
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-03

Review 5.  Paroxysmal Atrial Fibrillation: Novel Strategies for Monitoring and Implications for Treatment in Stroke.

Authors:  Scott B Silverman
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-08

Review 6.  Self-powered cardiovascular electronic devices and systems.

Authors:  Qiang Zheng; Qizhu Tang; Zhong Lin Wang; Zhou Li
Journal:  Nat Rev Cardiol       Date:  2020-09-07       Impact factor: 32.419

7.  2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry.

Authors:  Jonathan S Steinberg; Niraj Varma; Iwona Cygankiewicz; Peter Aziz; Paweł Balsam; Adrian Baranchuk; Daniel J Cantillon; Polychronis Dilaveris; Sergio J Dubner; Nabil El-Sherif; Jaroslaw Krol; Malgorzata Kurpesa; Maria Teresa La Rovere; Suave S Lobodzinski; Emanuela T Locati; Suneet Mittal; Brian Olshansky; Ewa Piotrowicz; Leslie Saxon; Peter H Stone; Larisa Tereshchenko; Mintu P Turakhia; Gioia Turitto; Neil J Wimmer; Richard L Verrier; Wojciech Zareba; Ryszard Piotrowicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-05       Impact factor: 1.468

8.  Yield and consistency of arrhythmia detection with patch electrocardiographic monitoring: The Multi-Ethnic Study of Atherosclerosis.

Authors:  Susan R Heckbert; Thomas R Austin; Paul N Jensen; James S Floyd; Bruce M Psaty; Elsayed Z Soliman; Richard A Kronmal
Journal:  J Electrocardiol       Date:  2018-07-30       Impact factor: 1.438

9.  2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-02-12

Review 10.  Transforming the care of atrial fibrillation with mobile health.

Authors:  Mintu P Turakhia; Daniel W Kaiser
Journal:  J Interv Card Electrophysiol       Date:  2016-06-15       Impact factor: 1.900