Literature DB >> 26877984

Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems.

Emmanuel João Nogueira Leal Silva1, Brenda Leite Muniz1, Frederico Pires1, Felipe Gonçalves Belladonna1, Aline Almeida Neves2, Erick Miranda Souza3, Gustavo De-Deus1.   

Abstract

OBJECTIVES: The purpose of this study was to assess the ability of ProTaper Gold (PTG, Dentsply Maillefer) in maintaining the original profile of root canal anatomy. For that, ProTaper Universal (PTU, Dentsply Maillefer) was used as reference techniques for comparison.
MATERIALS AND METHODS: Twenty simulated curved canals manufactured in clear resin blocks were randomly assigned to 2 groups (n = 10) according to the system used for canal instrumentation: PTU and PTG groups, upto F2 files (25/0.08). Color stereomicroscopic images from each block were taken exactly at the same position before and after instrumentation. All image processing and data analysis were performed with an open source program (FIJI). Evaluation of canal transportation was obtained for two independent canal regions: straight and curved levels. Student's t test was used with a cut-off for significance set at α = 5%.
RESULTS: Instrumentation systems significantly influenced canal transportation (p < 0.0001). A significant interaction between instrumentation system and root canal level (p < 0.0001) was found. PTU and PTG systems produced similar canal transportation at the straight part, while PTG system resulted in lower canal transportation than PTU system at the curved part. Canal transportation was higher at the curved canal portion (p < 0.0001).
CONCLUSIONS: PTG system produced overall less canal transportation in the curved portion when compared to PTU system.

Entities:  

Keywords:  Canal transportation; ProTaper Gold; Root canal instrumentation

Year:  2016        PMID: 26877984      PMCID: PMC4751201          DOI: 10.5395/rde.2016.41.1.1

Source DB:  PubMed          Journal:  Restor Dent Endod        ISSN: 2234-7658


Introduction

The use of nickel-titanium (NiTi) instruments has enhanced the overall shaping quality and the reduction of procedural errors, such as ledges, zips, perforations, and canal transportations.123 In short, NiTi files have raised new perspectives for mechanical canal preparation, such as less debris extrusion, better centering ability, and reduced learning curve.24 ProTaper Universal (PTU, Denstply Maillefer, Ballaigues, Switzerland) is a much studied rotary system made of conventional superelastic NiTi wire with convex triangular cross-sectional design and various percentage tapers over its length that enables active cutting motion and the removal of more dentin coronally.5 Recently, ProTaper Gold (PTG, Denstply Maillefer) was introduced onto the market. This new NiTi rotary system presents the same geometric design of PTU files, but is more flexible due to its development with proprietary advanced metallurgy and more resistance to fatigue.6 Investigations of the shaping effect of these new NiTi systems are becoming more important to understand how the file design and alloy affect their performance. Simulated curved canals in resin blocks have been traditionally used to evaluate the aspects of the shaping ability, including canal transportation and centering ability of different NiTi systems.78 However, a major limitation of most of proposed evaluation methods is the need of operator intervention, by pre-selecting evaluation points, to obtain the transportation measurements. An interesting root transportation analysis in simulated canals has been recently proposed, where an automatic approach measuring the entire simulated canal without operator intervention was used.9 This innovative method provides much less operator input, and bias reduction by providing results from the whole canal length, not only from pre-selected slices. The present study was designed to assess the ability of PTG and PTU in maintaining the original profile of root canal anatomy using simulated resin block canals. The null hypothesis tested was that there are no significant differences in canal transportation among the tested NiTi rotary systems.

Materials and Methods

Digital image acquisition

Twenty curved root canals simulated in clear resin blocks (Endo Training Blocks ISO 15, Dentsply Maillefer), with 2% taper, 10 mm radius of curvature, 60° angle of curvature and 17 mm length, were randomly assigned to 2 groups according to the instrumentation system (n = 10, PTU and PTG groups). Before any instrumentation procedures, a round silicon base with a rectangular slot was fit to the microscope base of a color stereomicroscope (1005t Opticam stereomicroscope, Opticam, São Paulo, Brazil) coupled to a digital camera (CMOS 10 megapixels, Opticam). The rectangular slot matched the exact dimensions of the simulated canal blocks. Each specimen was then inserted into the slot, and color images were taken and stored in TIFF format. After the instrumentation procedures, all blocks were imaged again following the same protocol. Ten resin blocks where no instrumentation was performed were used as a control group to check the reliability and consistency of the repositioning method. In this group, one color stereoscopic image of each block was taken. After that, the block was removed, and replaced back when another image was taken.

Canal instrumentation

For all groups, a stainless steel 10 and 15 K-file (Dentsply Maillefer) scouted the canal up to the working length (WL), creating an initial and standardized glide path. In PTU group, each simulated curved canal was prepared with PTU instruments used at 300 rpm and torque of 150 - 520 gcm as recommended by the manufacturer. The following sequence was used: SX file (1/2 of the WL), S1 file, S2 file, F1 and F2 files (full WL). In PTG group, PTG instruments were used following the same protocol of PTU as mentioned above. All instrumentation procedures were performed by a single operator with experience in rotary and reciprocating motions, and only new instruments were used. Between each preparation step, apical patency was confirmed using a size 10 K-file just beyond the WL, and canals were irrigated with 1.0 mL sterile water using a 30-G side-vented needle (Max-i-Probe, Dentsply Rinn, Elgin, IL, USA) placed to a depth just short of binding. After final irrigation with 1.0 mL sterile water, post instrumentation images were taken as described earlier.

Image processing and analysis

All image processing, registration, segmentation and extraction of attributes were performed within the FIJI open source software interface or one of its associated plugins.10 Image processing and analysis was based on a methodology previously described.9 Briefly, the images were first converted to 8-bit grayscale followed by registering each pair of images (baseline and after instrumentation) using the 'Rigid Registration' plugin.11 The baseline image was used as the template for the rigid transformation. A composite image from the baseline and instrumented canal after registration can be seen in Figure 1a.
Figure 1

(a) Composite image of superposition of baseline and instrumented canals after image registration; (b) Segmented instrumented canal; (c) Skeleton of instrumented canal.

Each canal (baseline and instrumented) was then segmented from the background using an iterative polygon tracing tool. Each line segment was defined by the user following the geometry of the canal and aided by an automatic segmentation algorithm to appropriately define the edges. After polygon definition, a simple binarization scheme (0 for background, 255 for the defined polygon) was applied (Figure 1b). A skeletonization algorithm was then applied to the segmented images. This algorithm uses binary thinning (symmetrical erosion) for finding the centerlines (skeleton) of objects in the input image.12 An example of the final centerline of each baseline and instrumented canals is depicted in Figure 1c. The XY coordinates of each skeleton were exported to a spreadsheet. The difference between each XY coordinate for the baseline and the instrumented skeleton images were calculated using the formula: where x and y are the coordinates for the baseline canal and x and y are the coordinates for the instrumented canal. Transportation measurements were obtained by converting the obtained values to millimeters (mm) with the aid of the microscope magnification scale. Transportation values were then averaged for two independent regions (straight and curved levels, Figure 2).
Figure 2

A schematic representation of evaluated regions (straight and curvature) in a sound simulated resin block canal.

Statistical analysis

Both canals portions generated several deviation values (straight = 26,360 and curved = 33,600), corresponding to each evaluated pixel. Each pixel has been considered as a unit for statistical analysis. Considering the data size, bell-shaped distribution has been assumed, and the t test for paired samples was used, with a cut-off significance level of α = 5%.

Results

No canal transportation was observed in the control group. Instrumentation systems significantly influenced canal transportation (p < 0.0001). Compared to the straight part of the simulated canal, transportation was higher at the curved canal portion (p < 0.0001). A significant interaction between instrumentation system and canal portion (p < 0.0001) indicated different effect patterns. Similar canal transportation was observed in PTU and PTG systems at the straight part, while PTG system resulted in lower transportation than PTU system at the curved part (Table 1).
Table 1

Measurements of canal transportation (Unit, mm) observed by ProTaper Universal and ProTaper Gold systems at straight and curved parts

SystemStraight canal partCurved canal part
Mean ± SD95% CIMean ± SD95% CI
ProTaper Universal0.055 ± 0.041a0.052 - 0.0580.099 ± 0.068a 0.096 - 0.101
ProTaper Gold0.053 ± 0.039a0.049 - 0.0550.088 ± 0.063b0.083 - 0.091

Different letters represent statistical differences between the groups in each column (p < 0.05).

SD, standard deviation; CI, confidence interval.

Discussion

One of the main goals during root canal instrumentation is the achievement of a shape that tapers from apical to coronal, maintaining the original root canal anatomy.13 However, several procedural errors such as canal transportation can occur when shaping curved root canals.14 Therefore, it is important to evaluate the efficiency of instruments designed for root canal preparation. Thus, this study compared the ability of PTU and PTG systems in maintaining the original profile of canal anatomy in simulated curved canals. PTG system presented overall less canal transportation in the curved portion when compared to PTU system. Therefore, the null hypothesis was rejected. As PTU and PTG systems feature an identical geometric architecture and operation mode, this result may be solely explained by their different manufacturing processes (metallic alloy), which clearly affect their stress-strain distribution patterns and bending behaviours, making PTG files more flexible and decreasing their tendency to straighten in curved canals.6 Many studies have already shown that instruments that are more flexible produce more centered root canal preparations.2913 The present results are also in accordance with a recent study using micro-computed tomographic imaging that showed less transportation to the PTG when compared to PTU.15 Although its values were much lower than in curved parts, canal transportation in the straight parts of the simulated canals was also detected herein. Overall, this outcome is not unusual.9 As files were used to the full extent of the simulated canals (including the curved portion), they are prompted to rectify, creating wear on the opposite curvature wall, explaining transportation in the straight portion. Simulated artificial canals have been already validated as satisfactory model to study the shaping ability of endodontic instruments; it is especially attractive due to the full standardization of the canal anatomy.91617 However, the use of resin blocks have some limitations including the difference in the micro-hardness when compared to root dentin, and the possible side effects created by heat generation during instrumentation which may soften the resin material and binding of instrument cutting blades.18 The present study used a recently described methodology to study transportation in simulated root canals by comparing registered images before and after instrumentation with different systems.9 This method considerably reduce bias related to a subjective visually-driven or operator-based image superimposition schemes and evaluation of canal transportation, since it is almost not dependent on user input. This also gives information from the whole canal length, not only from selected slices. Although the bidimensional approach stands for a clear limitation of the method, it is important to outline that current 3D-based techniques used to evaluate root canal transportation have not yet provided quantitative volumetric data, resulting in evaluation of limited selected slices and manual selection of center of gravity points.19202122

Conclusions

Under the conditions and within the limitations of the current study, it can be concluded that PTG system produced overall less canal transportation in the curved portion than PTU system.
  22 in total

1.  A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography.

Authors:  L Bergmans; J Van Cleynenbreugel; M Wevers; P Lambrechts
Journal:  Int Endod J       Date:  2001-07       Impact factor: 5.264

2.  Canal transportation after root canal instrumentation: a comparative study with computed tomography.

Authors:  Mateus Silveira Martins Hartmann; Fernando Branco Barletta; Vânia Regina Camargo Fontanella; José Roberto Vanni
Journal:  J Endod       Date:  2007-05-03       Impact factor: 4.171

3.  The shaping effect of the combination of two rotary nickel-titanium instruments in simulated S-shaped canals.

Authors:  Lan Zhang; Hong-xia Luo; Xue-dong Zhou; Hong Tan; Ding-ming Huang
Journal:  J Endod       Date:  2008-02-08       Impact factor: 4.171

4.  A method for the construction of simulated root canals in clear resin blocks.

Authors:  P M Dummer; M H Alodeh; M A al-Omari
Journal:  Int Endod J       Date:  1991-03       Impact factor: 5.264

5.  Quantitative Transportation Assessment in Simulated Curved Canals Prepared with an Adaptive Movement System.

Authors:  Emmanuel João Nogueira Leal Silva; Michele Dias Nunes Tameirão; Felipe Gonçalves Belladonna; Aline Almeida Neves; Erick Miranda Souza; Gustavo De-Deus
Journal:  J Endod       Date:  2015-04-01       Impact factor: 4.171

6.  Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

Authors:  Natasha C C Ajuz; Luciana Armada; Lucio S Gonçalves; Gilberto Debelian; José F Siqueira
Journal:  J Endod       Date:  2013-02-12       Impact factor: 4.171

7.  Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

Authors:  Gustavo De-Deus; Aline Neves; Emmanuel João Silva; Thais Accorsi Mendonça; Caroline Lourenço; Camila Calixto; Edson Jorge Moreira Lima
Journal:  Clin Oral Investig       Date:  2014-06-21       Impact factor: 3.573

8.  NIH Image to ImageJ: 25 years of image analysis.

Authors:  Caroline A Schneider; Wayne S Rasband; Kevin W Eliceiri
Journal:  Nat Methods       Date:  2012-07       Impact factor: 28.547

9.  Evaluation of the Shaping Characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in Curved Canals.

Authors:  Jason Gagliardi; Marco Aurélio Versiani; Manoel Damião de Sousa-Neto; Andres Plazas-Garzon; Bettina Basrani
Journal:  J Endod       Date:  2015-08-29       Impact factor: 4.171

Review 10.  Endodontic instrument fracture: causes and prevention.

Authors:  M B McGuigan; C Louca; H F Duncan
Journal:  Br Dent J       Date:  2013-04       Impact factor: 1.626

View more
  12 in total

1.  Comparison of vibration characteristics of file systems for root canal shaping according to file length.

Authors:  Seong-Jun Park; Se-Hee Park; Kyung-Mo Cho; Hyo-Jin Ji; Eun-Hye Lee; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2020-10-14

2.  Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers.

Authors:  Mario Tanomaru-Filho; Fernanda Ferrari Esteves Torres; Jader Camilo Pinto; Airton Oliveira Santos-Junior; Karina Ines Medina Carita Tavares; Juliane Maria Guerreiro-Tanomaru
Journal:  Restor Dent Endod       Date:  2020-06-09

3.  A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro.

Authors:  Zhao Wei; Zhi Cui; Ping Yan; Han Jiang
Journal:  BMC Oral Health       Date:  2017-01-09       Impact factor: 2.757

4.  Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography.

Authors:  Iussif Mamede-Neto; Alvaro Henrique Borges; Orlando Aguirre Guedes; Durvalino de Oliveira; Fábio Luis Miranda Pedro; Carlos Estrela
Journal:  Open Dent J       Date:  2017-02-14

5.  Shaping ability of four root canal instrumentation systems in simulated 3D-printed root canal models.

Authors:  David Christofzik; Andreas Bartols; Mahmoud Khaled Faheem; Doreen Schroeter; Birte Groessner-Schreiber; Christof E Doerfer
Journal:  PLoS One       Date:  2018-08-01       Impact factor: 3.240

6.  Shaping ability of ProTaper Gold and WaveOne Gold nickel-titanium rotary instruments in simulated S-shaped root canals.

Authors:  Lu Shi; Junling Zhou; Jie Wan; Yunfei Yang
Journal:  J Dent Sci       Date:  2021-08-30       Impact factor: 2.080

7.  Comparison of Canal Transportation, Separation Rate, and Preparation Time between One Shape and Neoniti (Neolix): An In Vitro CBCT Study.

Authors:  Maryam Kuzekanani; Faranak Sadeghi; Nima Hatami; Maryam Rad; Mansoureh Darijani; Laurence James Walsh
Journal:  Int J Dent       Date:  2021-09-07

8.  Shaping ability of ProTaper Gold, One Curve, and Self-Adjusting File systems in severely curved canals: A cone-beam computed tomography study.

Authors:  Meenu G Singla; Hemanshi Kumar; Ritika Satija
Journal:  J Conserv Dent       Date:  2021-12-08

9.  Canal Aberration Assessment in Simulated Root Canals: a Comparative Study.

Authors:  Selma Jakupovic; Alma Konjhodzic; Lajla Hasic Brankovic; Samra Korac; Irmina Tahmiscija; Aida Dzankovic; Alma Gavranovic Glamoc
Journal:  Med Arch       Date:  2017-06

10.  Influence of Two Preparation Techniques on Transportation of Simulated Type II Root Canals.

Authors:  Saeed Moradi; Maryam Gharechahi; Fatemeh Bonyadimanesh
Journal:  Iran Endod J       Date:  2018