Literature DB >> 20384272

Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: plan quality, delivery efficiency and accuracy.

Min Rao1, Wensha Yang, Fan Chen, Ke Sheng, Jinsong Ye, Vivek Mehta, David Shepard, Daliang Cao.   

Abstract

PURPOSE: Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are arc-based approaches to IMRT delivery. The objective of this study is to compare VMAT to both HT and fixed field IMRT in terms of plan quality, delivery efficiency, and accuracy.
METHODS: Eighteen cases including six prostate, six head-and-neck, and six lung cases were selected for this study. IMRT plans were developed using direct machine parameter optimization in the Pinnacle3 treatment planning system. HT plans were developed using a Hi-Art II planning station. VMAT plans were generated using both the Pinnacle3 SmartArc IMRT module and a home-grown arc sequencing algorithm. VMAT and HT plans were delivered using Elekta's PreciseBeam VMAT linac control system (Elekta AB, Stockholm, Sweden) and a TomoTherapy Hi-Art II system (TomoTherapy Inc., Madison, WI), respectively. Treatment plan quality assurance (QA) for VMAT was performed using the IBA MatriXX system while an ion chamber and films were used for HT plan QA.
RESULTS: The results demonstrate that both VMAT and HT are capable of providing more uniform target doses and improved normal tissue sparing as compared with fixed field IMRT. In terms of delivery efficiency, VMAT plan deliveries on average took 2.2 min for prostate and lung cases and 4.6 min for head-and-neck cases. These values increased to 4.7 and 7.0 min for HT plans.
CONCLUSIONS: Both VMAT and HT plans can be delivered accurately based on their own QA standards. Overall, VMAT was able to provide approximately a 40% reduction in treatment time while maintaining comparable plan quality to that of HT.

Entities:  

Mesh:

Year:  2010        PMID: 20384272     DOI: 10.1118/1.3326965

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  81 in total

1.  Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Hui-Min Ting; Su-Hua Lo; Yu-Wen Wang; Chiu-Ching Tuan; Fu-Min Fang; Te-Jen Su
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

Review 2.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

3.  Multicriteria VMAT optimization.

Authors:  David Craft; Dualta McQuaid; Jeremiah Wala; Wei Chen; Ehsan Salari; Thomas Bortfeld
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

4.  Long-Term Pulmonary Outcomes of a Feasibility Study of Inverse-Planned, Multibeam Intensity Modulated Radiation Therapy in Node-Positive Breast Cancer Patients Receiving Regional Nodal Irradiation.

Authors:  Alice Y Ho; Ase Ballangrud; Guang Li; Gaorav P Gupta; Beryl McCormick; Richard Gewanter; Daphna Gelblum; Melissa Zinovoy; Boris Mueller; Borys Mychalczak; Pinaki Dutta; Karen Borofsky; Preeti Parhar; Marsha Reyngold; Lior Z Braunstein; Mohit Chawla; Kate Krause; Natasha Freeman; Chun Ting Siu; Zachary Cost; Brittany B Arnold; Zhigang Zhang; Simon N Powell
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-11-30       Impact factor: 7.038

5.  The potential of helical tomotherapy in the treatment of head and neck cancer.

Authors:  Dirk Van Gestel; Dirk Verellen; Lien Van De Voorde; Bie de Ost; Geert De Kerf; Olivier Vanderveken; Carl Van Laer; Danielle Van den Weyngaert; Jan B Vermorken; Vincent Gregoire
Journal:  Oncologist       Date:  2013-05-30

6.  Exploring trade-offs between VMAT dose quality and delivery efficiency using a network optimization approach.

Authors:  Ehsan Salari; Jeremiah Wala; David Craft
Journal:  Phys Med Biol       Date:  2012-08-14       Impact factor: 3.609

7.  VMAT optimization with dynamic collimator rotation.

Authors:  Qihui Lyu; Daniel O'Connor; Dan Ruan; Victoria Yu; Dan Nguyen; Ke Sheng
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

8.  Target tracking using DMLC for volumetric modulated arc therapy: a simulation study.

Authors:  Baozhou Sun; Dharanipathy Rangaraj; Lech Papiez; Swetha Oddiraju; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

9.  Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification.

Authors:  X Jin; H Yan; C Han; Y Zhou; J Yi; C Xie
Journal:  Br J Radiol       Date:  2014-12-10       Impact factor: 3.039

10.  Automated volumetric modulated Arc therapy treatment planning for stage III lung cancer: how does it compare with intensity-modulated radio therapy?

Authors:  Enzhuo M Quan; Joe Y Chang; Zhongxing Liao; Tingyi Xia; Zhiyong Yuan; Hui Liu; Xiaoqiang Li; Cody A Wages; Radhe Mohan; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-09-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.