| Literature DB >> 26855927 |
Woo Jung Kim1, Sang Young Park1, Iksoo Park1, Wook Jin Lee1, Jaechan Park1, Nuri Chon1, Tak Geun Oh1, Kwang Hyun Kim1.
Abstract
BACKGROUND/AIMS: The aim of this study was to evaluate the efficacy of high definition (HD) i-SCAN for colorectal polyp detection in screening colonoscopy.Entities:
Keywords: Chromoendoscopy; Colonic polyps; Colonoscopy; i-SCAN
Year: 2016 PMID: 26855927 PMCID: PMC4743733 DOI: 10.5946/ce.2016.49.1.69
Source DB: PubMed Journal: Clin Endosc ISSN: 2234-2400
Baseline Characteristics and Colonoscopy Quality Assessment
| Characteristic | HD i-SCAN (n=148) | Standard WL (n=344) | |
|---|---|---|---|
| Age, yr | 51.61±12.27 | 51.07±11.50 | 0.995 |
| Male sex | 90 (60.8) | 187 (54.4) | 0.186 |
| Withdrawal time, min | |||
| Overall | 7.18±2.54 (6–30) | 6.80±1.75 (6–25) | 0.007 |
| Polyp detection | 8.18±3.20 (6–30) | 8.02±2.37 (6–25) | 0.896 |
| Not polyp detection | 6.10±0.35 (6–8) | 6.05±0.21 (6–7) | 0.227 |
| Bowel preparation | 0.450 | ||
| Excellent | 60 (40.5) | 123 (35.1) | |
| Good | 72 (48.6) | 172 (50.0) | |
| Fair | 16 (10.8) | 49 (14.2) |
Values are presented as mean±SD, number (%), or mean±SD (range).
HD, high definition; WL, white light.
Interendoscopist Variation
| Variable | Endoscopist 1 (n=189) | Endoscopist 2 (n=141) | Endoscopist 3 (n=162) | |
|---|---|---|---|---|
| Rates of i-SCAN use | 60 (31.7) | 43 (30.5) | 45 (27.8) | 0.716 |
| Colorectal polyp detection | 83 (43.9) | 54 (38.3) | 71 (43.3) | 0.527 |
| Neoplastic polyp detection | 58 (30.7) | 40 (28.4) | 53 (32.7) | 0.715 |
Values are presented as number (%).
Colorectal and Neoplastic Polyp Detection Rate
| Characteristic | HD i-SCAN (n=148) | Standard WL (n=344) | |
|---|---|---|---|
| Colorectal polyp | 77 (52) | 131 (38.1) | 0.004 |
| Neoplastic polyp | 55 (37.2) | 96 (27.9) | 0.041 |
| Mean colorectal polyp | 0.96±1.38 | 0.71±1.26 | 0.005 |
| Mean neoplastic polyp | 0.66±1.24 | 0.50±1.08 | 0.044 |
Values are presented as number (%) or mean±SD.
HD, high definition; WL, white light.
Characteristics of Endoscopic and Pathologic Findings of Identified Colorectal Polyps
| Characteristic | HD i-SCAN (n=134) | Standard WL (n=229) | |
|---|---|---|---|
| Size, mm | 4.59±2.35 | 4.82±2.81 | 0.739 |
| Morphology | 0.007 | ||
| Protruding | 101 (75.4) | 198 (86.5) | |
| Non-protruding | 33 (24.6) | 31 (13.5) | |
| Location | 0.472 | ||
| Right side | 59 (44.0) | 92 (40.2) | |
| Left side | 75 (56.0) | 137 (59.8) | |
| Pathology | 0.351 | ||
| Low grade dysplasia | 82 (61.2) | 138 (60.3) | |
| High grade dysplasia | 0 | 4 (1.7) | |
| Tubulovillous adenoma | 3 (2.2) | 10 (4.4) | |
| Serrated adenoma | 8 (6) | 7 (3.1) | |
| Hyperplastic | 14 (10.4) | 30 (13.1) | |
| Carcinoma | 0 | 1 (0.4) | |
| Others[ | 27 (20) | 39 (20.1) | |
| Neoplastic vs. non | 0.926 | ||
| Neoplastic polyp | 93 (69.4) | 160 (69.9) | |
| Non-neoplastic polyp | 41 (30.6) | 69 (30.1) |
Values are presented as mean±SD or number (%).
HD, high definition; WL, white light.
Inflammatory polyp, mucosal nodule.
Summary of Five Studies Evaluating the Efficacy of HD i-SCAN for Colorectal Polyp Detection
| Study | No. of patients | Design | Study population | Detail of intervention | Control group | Efficacy for polyp detection | Note |
|---|---|---|---|---|---|---|---|
| Hoffman et al. (2010)[ | 220 | Prospective, randomized, controlled | Screening | HD i-SCAN (SE) | Standard WL | Positive | Full colonoscopy |
| Surveillance | |||||||
| Hoffman et al. (2010)[ | 69 | Prospective randomized | Screening | HD i-SCAN (SE), chromoendoscopy (methylene blue) | HD WL | Positive | Last 30 cm of the colon |
| Testoni et al. (2012)[ | 1,101 | Retrospective | Screening | HD i-SCAN (SE/CE/TE) | Standard WL | Positive | Full colonoscopy |
| Diagnostic | |||||||
| Surveillance | |||||||
| Hong et al. (2012)[ | 389 | Prospective, randomized, back-to-back | Screening | HD i-SCAN (SE/CE) | HD WL | Negative | Full colonoscopy |
| HD i-SCAN (SE/CE/TE) | |||||||
| Hoffman et al. (2014)[ | 80 | Prospective, randomized, tandem | Screening | HD i-SCAN (TE) | HD WL | Positive | Full colonoscopy |
| Surveillance |
HD, high definition; SE, surface enhancement; WL, white light; CE, contrast enhancement; TE, tone enhancement.