Literature DB >> 26855834

Ultrasound Imaging Improves Identification of Prominent Hardware in the Surgical Treatment of Distal Radius Fractures: A Cadaveric and Prospective Clinical Study.

Jacqueline D Watchmaker1, Roger A Daley1, Greg P Watchmaker2, Steven I Grindel1.   

Abstract

Background Volarly applied locking plates are one of several current treatment options for displaced fractures of the distal radius. Presently, surgeons use intraoperative depth gauges and fluoroscopy to select and confirm proper screw length. The contour of the dorsal cortex beneath the extensor compartments along with fracture comminution may limit the accuracy of screw length selection. Question/Purpose To evaluate the accuracy of ultrasound (US) and fluoroscopy in the detection of dorsally prominent screws placed during volar plating of experimentally created distal radius fractures and extend this prospectively into the clinical setting. Patients and Methods Distal radius fractures were experimentally induced in fresh cadaveric arms. The fractures were then internally fixated with volar locking plates utilizing fluoroscopic imaging. US imaging of the dorsal surface of the radius was then performed followed by dorsal dissection and direct caliper measurements to quantitate screw tips as recessed, flush, or protruding from the dorsal cortex. A small, prospective clinical study was also conducted to validate the clinical usefulness of using US to provide additional information regarding screw tip prominence. Results Our study demonstrated that US was able to detect dorsally prominent screw tips not visible on fluoroscopy. Cadaveric dissection showed a higher statistical correlation between US imaging and actual prominence than between fluoroscopy and actual prominence. Conclusions US examination after volar plate fixation of comminuted distal radius fractures may detect dorsal screw tip prominence when screw lengths are selected to engage the dorsal cortex. Level of Evidence IV.

Entities:  

Keywords:  distal radius; fluoroscopy; fracture; ultrasound; volar plate

Year:  2015        PMID: 26855834      PMCID: PMC4742260          DOI: 10.1055/s-0035-1569485

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  18 in total

1.  Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius.

Authors:  Kagan Ozer; Jennifer M Wolf; Bruce Watkins; David J Hak
Journal:  J Hand Surg Am       Date:  2012-04-04       Impact factor: 2.230

2.  Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur. 2009, 34: 598-602.

Authors:  J Jacob; N R Clay
Journal:  J Hand Surg Eur Vol       Date:  2010-05

3.  Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius.

Authors:  J S Bell; R Wollstein; N D Citron
Journal:  J Bone Joint Surg Br       Date:  1998-03

4.  Two potential causes of EPL rupture after distal radius volar plate fixation.

Authors:  Eric C Benson; Alex DeCarvalho; Elizabeth A Mikola; John M Veitch; Moheb S Moneim
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

5.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

Authors:  M Al-Rashid; K Theivendran; M A C Craigen
Journal:  J Bone Joint Surg Br       Date:  2006-12

6.  Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?

Authors:  Kenneth J Koval; John J Harrast; Jeffrey O Anglen; James N Weinstein
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

7.  Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases.

Authors:  J M Failla; M P Koniuch; B R Moed
Journal:  J Hand Surg Am       Date:  1993-07       Impact factor: 2.230

8.  Distal radial fracture treatment: what you get may depend on your age and address.

Authors:  Jason Fanuele; Kenneth J Koval; Jon Lurie; Weiping Zhou; Anna Tosteson; David Ring
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

9.  Epidemiology of acute wrist trauma.

Authors:  C F Larsen; J Lauritsen
Journal:  Int J Epidemiol       Date:  1993-10       Impact factor: 7.196

10.  Incidence and clinical outcomes of tendon rupture following distal radius fracture.

Authors:  Brian D White; Jason A Nydick; Dawnne Karsky; Bailee D Williams; Alfred V Hess; Jeffrey D Stone
Journal:  J Hand Surg Am       Date:  2012-09-01       Impact factor: 2.230

View more
  3 in total

1.  Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study.

Authors:  M Artuso; M Protais; O Herisson; A Miquel; A Cambon-Binder; A Sautet
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-04

2.  Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation.

Authors:  Yunus Oc; Bekir Eray Kilinc; Anıl Gulcu; Ali Varol; Rodi Ertugrul; Adnan Kara
Journal:  J Orthop Surg Res       Date:  2018-04-03       Impact factor: 2.359

3.  Intraoperative sonography may reduce the risk of extensor pollicis longus tendon injury during dorsal entry elastic intramedullary nailing of the radius in children.

Authors:  Marcell Varga; Nikoletta Gáti; Tamás Kassai; Szilvia Papp; Sándor Pintér
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.