Literature DB >> 26830222

Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Hisato Takagi1, Takuya Umemoto2.   

Abstract

BACKGROUND: We reviewed currently available studies that investigated prosthesis-patient mismatch (PPM) in transcatheter aortic valve implantation (TAVI) with a systematic literature search and meta-analytic estimates.
METHODS: To identify all studies that investigated PPM in TAVI, MEDLINE and EMBASE were searched through August 2015. Studies considered for inclusion met the following criteria: the study population included patients undergoing TAVI and outcomes included at least post-procedural PPM prevalence. We performed three quantitative meta-analyses about (1) PPM prevalence after TAVI, (2) PPM prevalence after TAVI versus surgical aortic valve replacement (SAVR), and (3) late all-cause mortality after TAVI in patients with PPM versus patients without PPM.
RESULTS: We identified 21 eligible studies that included data on a total of 4,000 patients undergoing TAVI. The first meta-analyses found moderate PPM prevalence of 26.7%, severe PPM prevalence of 8.0%, and overall PPM prevalence of 35.1%. The second meta-analyses of six studies, including 745 patients, found statistically significant reductions in moderate (p = 0.03), severe (p = 0.0003), and overall (p = 0.02) PPM prevalence after TAVI relative to SAVR. The third meta-analyses of five studies, including 2,654 patients, found no statistically significant differences in late mortality between patients with severe PPM and patients without PPM (p = 0.44) and between patients with overall PPM and patients without PPM (p = 0.97).
CONCLUSIONS: Overall, moderate, and severe PPM prevalence after TAVI was 35%, 27%, and 8%, respectively, which may be less than that after SAVR. In contrast to PPM after SAVR, PPM after TAVI may not impair late survival.
Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26830222     DOI: 10.1016/j.athoracsur.2015.11.048

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  14 in total

1.  Comparison of hemodynamic and clinical outcomes of transcatheter and sutureless aortic bioprostheses: how to make the right choice in intermediate risk patients.

Authors:  Augusto D'Onofrio; Assunta Fabozzo; Gino Gerosa
Journal:  Ann Cardiothorac Surg       Date:  2017-09

2.  Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation.

Authors:  Hatim Seoudy; Nathalie Güßefeld; Johanne Frank; Sandra Freitag-Wolf; Georg Lutter; Matthias Eden; Ashraf Yusuf Rangrez; Christian Kuhn; Norbert Frey; Derk Frank
Journal:  Clin Res Cardiol       Date:  2018-11-19       Impact factor: 5.460

3.  Patient-specific in vitro testing for evaluating TAVR clinical performance-A complementary approach to current ISO standard testing.

Authors:  Brandon J Kovarovic; Oren M Rotman; Puja Parikh; Marvin J Slepian; Danny Bluestein
Journal:  Artif Organs       Date:  2020-12-07       Impact factor: 3.094

Review 4.  Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation.

Authors:  Shigeki Morita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-05-27

5.  Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation - predictors, incidence and impact on clinical efficacy. A preliminary study.

Authors:  Karol Zbroński; Bartosz Rymuza; Piotr Scisło; Kajetan Grodecki; Paulina Dobkowska; Marek Wawrzacz; Radosław Wilimski; Anna Słowikowska; Janusz Kochman; Krzysztof J Filipiak; Grzegorz Opolski; Zenon Huczek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-11-29       Impact factor: 1.426

Review 6.  Prosthesis-patient mismatch - what cardiac anesthesiologists need to know?

Authors:  Kathirvel Subramaniam; Soheyla Nazarnia
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

7.  Utility of conventional aortic root shot angiography for SAPIEN 3 prosthesis sizing in TAVI: feasibility and inter-reader variability.

Authors:  Laura Gansera; Bernhard Ulm; Peter Bramlage; Stephan Krapf; Frank Oertel; Tobias Mueller-Honold; Wolfgang von Scheidt; Christian Thilo
Journal:  Open Heart       Date:  2019-12-29

8.  Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study.

Authors:  Mohamad Kanso; Marion Kibler; Sebastien Hess; Jérome Rischner; Philoktimon Plastaras; Michel Kindo; Minh Hoang; Fabien De Poli; Pierre Leddet; Hélène Petit; Floriane Zeyons; Annie Trinh; Kensuke Matsushita; Olivier Morel; Patrick Ohlmann
Journal:  J Clin Med       Date:  2021-01-07       Impact factor: 4.241

Review 9.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04

Review 10.  Sex and Transcatheter Aortic Valve Implantation: Impact of Female Sex on Clinical Outcomes.

Authors:  Alessandra Laricchia; Barbara Bellini; Vittorio Romano; Saud Khawaja; Matteo Montorfano; Alaide Chieffo
Journal:  Interv Cardiol       Date:  2019-11-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.