Literature DB >> 26803224

Cost-effectiveness model comparing dual-mobility to fixed-bearing designs for total hip replacement in France.

J-A Epinette1, A Lafuma2, J Robert2, M Doz2.   

Abstract

BACKGROUND: Instability is among the main causes of total hip arthroplasty (THA) failure. In clinical studies, THA with a dual-mobility cup (THA-DM) decreased the risk of instability after primary THA compared to THA with a fixed-bearing design (THA-FB). However, whether THA-DM is more cost-effective than THA-FB has not been established using Markov modelling with determination of the incremental cost-effectiveness ratio (ICER). The objectives of this work were to: (1) measure the efficiency of these two options, (2) use the nationwide hospital electronic database (PMSI) to estimate direct costs of dislocations and revisions for instability, and (3) conduct deterministic and probabilistic sensitivity analyses to estimate potential mean annual cost-savings in France. HYPOTHESIS: We hypothesised that primary THA-DM was cost-saving compared to primary THA-FB.
MATERIAL AND METHODS: In the database, we identified 80,405 patients who had THA in 2009 and we collected their outcomes over 4 years (2009-2012). Cost-effectiveness was assessed based on the costs of resources used for all consequences of prosthetic dislocation and paid for by the statutory health insurance system or other sources.
RESULTS: THA-DM was associated with a relative risk of dislocation of 0.4 versus THA-FB. This risk difference translated into 3283 fewer dislocations per 100,000 patients with THA-DM. The corresponding cost-savings for the 140,000 primary THA procedures done in France annually was 39.62 million Euros. A relative risk of 0.2 would yield annual cost-savings of 56.28 million Euros. In the probabilistic sensitivity analysis, THA-DM was the less costly option under all hypotheses, with potential maximum cost-savings of more than 100 million Euros per year in France. DISCUSSION: This comparative cost-effectiveness analysis suggests that THA-DM may induce substantial cost-savings compared to THA-FB. This possibility should be assessed by long-term clinical studies of new-generation DM prostheses.
Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Bearings; Cost-effectiveness; Dislocation; Dual mobility; Economic analysis; Hip replacement; Incremental cost-effectiveness ratio; Instability; Markov model; THA; THR

Mesh:

Year:  2016        PMID: 26803224     DOI: 10.1016/j.otsr.2015.12.008

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  11 in total

1.  Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

Authors:  Jean-Alain Epinette; Steven F Harwin; Fiachra E Rowan; Philippe Tracol; Michael A Mont; Morad Chughtai; Geoffrey H Westrich
Journal:  Int Orthop       Date:  2016-12-24       Impact factor: 3.075

2.  Lack of early dislocation for dual mobility vs. fixed bearing total hip arthroplasty: A multi-center analysis of comparable cohorts.

Authors:  J A Dubin; G H Westrich
Journal:  J Orthop       Date:  2020-02-04

3.  Five-Year Follow-Up of Clinical Outcomes with an Anatomic Dual-Mobility Acetabular System: A Multicenter Study.

Authors:  Jeremy Dubin; Ronald C Huang; Ahava Muskat; Kipling Sharpe; Art L Malkani; Michael Mont; Geoffrey Westrich
Journal:  Arthroplast Today       Date:  2020-07-27

4.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

Review 5.  Dual mobility total hip arthroplasty: should everyone get one?

Authors:  William G Blakeney; Jean-Alain Epinette; Pascal-André Vendittoli
Journal:  EFORT Open Rev       Date:  2019-09-03

6.  Advances and innovations in total hip arthroplasty.

Authors:  Andreas Fontalis; Jean-Alain Epinette; Martin Thaler; Luigi Zagra; Vikas Khanduja; Fares S Haddad
Journal:  SICOT J       Date:  2021-04-12

7.  Is Isolated Mobile Component Exchange an Option in the Management of Intraprosthetic Dislocation of a Dual Mobility Cup?

Authors:  Julien Wegrzyn; Matthieu Malatray; Vincent Pibarot; Gaetano Anania; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2020-02       Impact factor: 4.755

Review 8.  Dual mobility in primary total hip arthroplasty: current concepts.

Authors:  Rory Cuthbert; James Wong; Philip Mitchell; Parag Kumar Jaiswal
Journal:  EFORT Open Rev       Date:  2019-11-08

9.  A cost-effectiveness assessment of dual-mobility bearings in revision hip arthroplasty.

Authors:  Amir Khoshbin; Fares S Haddad; Sarah Ward; S O hEireamhoin; James Wu; Leo Nherera; Amit Atrey
Journal:  Bone Joint J       Date:  2020-09       Impact factor: 5.082

10.  Study protocol: Effectiveness of dual-mobility cups compared with uni-polar cups for preventing dislocation after primary total hip arthroplasty in elderly patients - design of a randomized controlled trial nested in the Dutch Arthroplasty Registry.

Authors:  Loes W A H Van Beers; Bart C H Van Der Wal; Tess Glastra Van Loon; Dirk Jan F Moojen; Marieke F Van Wier; Amanda D Klaassen; Nienke W Willigenburg; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2020-08-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.