Literature DB >> 26801662

Impact of parametric imaging on contrast-enhanced ultrasound of breast cancer.

Aya Noro1, Takashi Nakamura2, Toshiko Hirai3, Masayo Haga4, Toyoki Kobayashi5, Akinobu Hayashi6, Yuji Kozuka6, Tokiko Nakai7, Toru Ogura8, Tomoko Ogawa9.   

Abstract

PURPOSE: To prospectively evaluate the usefulness of contrast-enhanced ultrasound (CEUS) using parametric imaging for breast cancer in a multicenter study.
METHODS: A total of 65 patients with breast cancer were included in this study. CEUS was performed, and still images on peak time (S), accumulated images (A) and parametric images (P) were generated from the raw data. Four blind reviewers ranked the best visible images as first place, and determined second and third place consecutively. We compared the average ranking of each image. The maximal diameter of the tumor determined on ultrasonography and MRI was compared with the corresponding pathological maximal diameter for 48 of the 65 patients. The correlation between the diameter determined by two experts and two beginners was analyzed.
RESULTS: The average rank of visibility was as follows: P, 1.44; A, 2.04; and S, 2.52. The correlation between each image and the pathology was as follows: P, r = 0.664; A, r = 0.630; S, r = 0.717; and MRI, r = 0.936. There were no significant differences among the correlation between the experts and beginners in each image.
CONCLUSIONS: The use of parametric imaging improves the visibility of CEUS. The maximal diameter of the tumor determined on CEUS correlates substantially with the pathology.

Entities:  

Keywords:  Breast cancer; Contrast-enhanced ultrasound; Parametric image; Sonazoid®; Visibility

Mesh:

Substances:

Year:  2016        PMID: 26801662     DOI: 10.1007/s10396-015-0692-7

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  17 in total

1.  Differentiating benign from malignant solid breast lesions: combined utility of conventional ultrasound and contrast-enhanced ultrasound in comparison with magnetic resonance imaging.

Authors:  Jing Du; Lin Wang; Cai-Feng Wan; Jia Hua; Hua Fang; Jie Chen; Feng-Hua Li
Journal:  Eur J Radiol       Date:  2012-10-11       Impact factor: 3.528

2.  The detection of pCR after PST by contrast-enhanced ultrasonography for breast cancer.

Authors:  Tomomi Fujisawa; Tomoko Hirakata; Yasuhiro Yanagita; Misa Iijima; Hiroyuki Horikoshi; Koji Takeuchi; Yumi Saitoh
Journal:  Breast Cancer       Date:  2011-12-28       Impact factor: 4.239

Review 3.  Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: systematic review and meta-analysis in detection of multifocal and multicentric cancer.

Authors:  Nehmat Houssami; Stefano Ciatto; Petra Macaskill; Sarah J Lord; Ruth M Warren; J Michael Dixon; Les Irwig
Journal:  J Clin Oncol       Date:  2008-05-12       Impact factor: 44.544

4.  Contrast-enhanced US and MRI for assessing the response of breast cancer to neoadjuvant chemotherapy().

Authors:  B Corcioni; L Santilli; S Quercia; C Zamagni; D Santini; M Taffurelli; S Mignani
Journal:  J Ultrasound       Date:  2008-11-14

5.  Breast tumor size assessment: comparison of conventional ultrasound and contrast-enhanced ultrasound.

Authors:  Yu-Xin Jiang; He Liu; Ji-Bin Liu; Qing-Li Zhu; Qiang Sun; Xiao-Yan Chang
Journal:  Ultrasound Med Biol       Date:  2007-08-08       Impact factor: 2.998

6.  Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent.

Authors:  C Boetes; R D Mus; R Holland; J O Barentsz; S P Strijk; T Wobbes; J H Hendriks; S H Ruys
Journal:  Radiology       Date:  1995-12       Impact factor: 11.105

7.  Contrast-enhanced ultrasound is helpful in the differentiation of malignant and benign breast lesions.

Authors:  Hongjia Zhao; Rong Xu; Qiufang Ouyang; Lidian Chen; Baowei Dong; Ye Huihua
Journal:  Eur J Radiol       Date:  2009-06-25       Impact factor: 3.528

8.  Arrival time parametric imaging using Sonazoid-enhanced ultrasonography is useful for the detection of spoke-wheel patterns of focal nodular hyperplasia smaller than 3 cm.

Authors:  Noritaka Wakui; Ryuji Takayama; Naohisa Kamiyama; Kojiro Kobayashi; Daigo Matsui; Yasushi Matsukiyo; Takenori Kanekawa; Takashi Ikehara; Koji Ishii; Yasukiyo Sumino
Journal:  Exp Ther Med       Date:  2013-04-04       Impact factor: 2.447

9.  Accuracy of contrast-enhanced breast ultrasound for pre-operative tumor size assessment in patients diagnosed with invasive ductal carcinoma of the breast.

Authors:  S van Esser; W B Veldhuis; R van Hillegersberg; P J van Diest; G Stapper; M ElOuamari; I H M Borel Rinkes; W P Th M Mali; M A A J van den Bosch
Journal:  Cancer Imaging       Date:  2007-05-15       Impact factor: 3.909

10.  Arrival time parametric imaging of the hemodynamic balance changes between the hepatic artery and the portal vein during deep inspiration, using Sonazoid-enhanced ultrasonography: A case of Budd-Chiari syndrome.

Authors:  Noritaka Wakui; Ryuji Takayama; Yasushi Matsukiyo; Naohisa Kamiyama; Kojiro Kobayashi; Takanori Mukozu; Shigeru Nakano; Takashi Ikehara; Hidenari Nagai; Yoshinori Igarashi; Yasukiyo Sumino
Journal:  Exp Ther Med       Date:  2013-05-09       Impact factor: 2.447

View more
  2 in total

1.  Interpretation of cardiac wall motion from cine-MRI combined with parametric imaging based on the Hilbert transform.

Authors:  Narjes Benameur; Enrico Gianluca Caiani; Younes Arous; Nejmeddine Ben Abdallah; Tarek Kraiem
Journal:  MAGMA       Date:  2017-02-20       Impact factor: 2.310

2.  Comparison of tumor angiogenesis in subcutaneous and orthotopic LNCaP mouse models using contrast-enhanced ultrasound imaging.

Authors:  Weiyong Liu; Yunkai Zhu; Lei Ye; Yajuan Zhu; Yuhao Wang
Journal:  Transl Cancer Res       Date:  2021-07       Impact factor: 1.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.