Literature DB >> 26800532

Statistical Modeling of Retinal Optical Coherence Tomography.

Zahra Amini, Hossein Rabbani.   

Abstract

In this paper, a new model for retinal Optical Coherence Tomography (OCT) images is proposed. This statistical model is based on introducing a nonlinear Gaussianization transform to convert the probability distribution function (pdf) of each OCT intra-retinal layer to a Gaussian distribution. The retina is a layered structure and in OCT each of these layers has a specific pdf which is corrupted by speckle noise, therefore a mixture model for statistical modeling of OCT images is proposed. A Normal-Laplace distribution, which is a convolution of a Laplace pdf and Gaussian noise, is proposed as the distribution of each component of this model. The reason for choosing Laplace pdf is the monotonically decaying behavior of OCT intensities in each layer for healthy cases. After fitting a mixture model to the data, each component is gaussianized and all of them are combined by Averaged Maximum A Posterior (AMAP) method. To demonstrate the ability of this method, a new contrast enhancement method based on this statistical model is proposed and tested on thirteen healthy 3D OCTs taken by the Topcon 3D OCT and five 3D OCTs from Age-related Macular Degeneration (AMD) patients, taken by Zeiss Cirrus HD-OCT. Comparing the results with two contending techniques, the prominence of the proposed method is demonstrated both visually and numerically. Furthermore, to prove the efficacy of the proposed method for a more direct and specific purpose, an improvement in the segmentation of intra-retinal layers using the proposed contrast enhancement method as a preprocessing step, is demonstrated.

Entities:  

Mesh:

Year:  2016        PMID: 26800532     DOI: 10.1109/TMI.2016.2519439

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Assessment of corneal properties based on statistical modeling of OCT speckle.

Authors:  Danilo A Jesus; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2016-12-08       Impact factor: 3.732

2.  Tri-Scan: A Three Stage Color Enhancement Tool for Endoscopic Images.

Authors:  Mohammad S Imtiaz; Shahed K Mohammed; Farah Deeba; Khan A Wahid
Journal:  J Med Syst       Date:  2017-05-20       Impact factor: 4.460

3.  Retinal optical coherence tomography image analysis by a restricted Boltzmann machine.

Authors:  Mansooreh Ezhei; Gerlind Plonka; Hossein Rabbani
Journal:  Biomed Opt Express       Date:  2022-08-04       Impact factor: 3.562

4.  Statistical Models of Signal and Noise and Fundamental Limits of Segmentation Accuracy in Retinal Optical Coherence Tomography.

Authors:  Theodore B Dubose; David Cunefare; Elijah Cole; Peyman Milanfar; Joseph A Izatt; Sina Farsiu
Journal:  IEEE Trans Med Imaging       Date:  2017-11-13       Impact factor: 10.048

5.  Influence of eye biometrics and corneal micro-structure on noncontact tonometry.

Authors:  Danilo A Jesus; Małgorzata Majewska; Patrycja Krzyżanowska-Berkowska; D Robert Iskander
Journal:  PLoS One       Date:  2017-05-04       Impact factor: 3.240

  5 in total