Literature DB >> 26796774

The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty.

Harry S Hothi1, Reshid Berber1, Robert K Whittaker1, Gordon W Blunn1, John A Skinner1, Alister J Hart1.   

Abstract

BACKGROUND: The size of the clinical impact of corrosion of the taper junction of metal-on-metal total hip arthroplasties (MOM-THAs) is unclear. Examination of a large number of retrieved MOM resurfacings and total hip arthroplasties can help us understand the role of taper corrosion in metal ion release.
METHODS: We graded the severity of corrosion at the taper junction of 395 MOM-THAs and compared the prerevision whole blood metal ion levels of these hips with 529 failed MOM hip resurfacings.
RESULTS: Virtually all MOM-THA hips (n = 388) had evidence of corrosion of the head-stem taper junction and graded as severe in 31% (n = 124). The median cobalt/chromium (Co/Cr) ratio was 1.58 (0.01-13.82) and 1.08 (0-4.86) for MOM-THA and MOM hip resurfacing, respectively; this difference was significant (P < .001). THA hips with severely corroded tapers had the highest median Co/Cr ratio of 1.86 (0.01-10).
CONCLUSIONS: This study demonstrates the high prevalence of severe taper corrosion, which may be related to an elevated Co/Cr ratio before revision.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  chromium; cobalt; corrosion; metal-on-metal; retrieval; taper

Mesh:

Substances:

Year:  2015        PMID: 26796774     DOI: 10.1016/j.arth.2015.11.014

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  Revision of ASR hip arthroplasty: analysis of two hundred and ninety six recalled patients at seven years.

Authors:  Giovanni Benelli; Merildo Maritato; Pierpaolo Cerulli Mariani; Francesco Sasso
Journal:  Int Orthop       Date:  2018-09-07       Impact factor: 3.075

Review 2.  Revision total hip arthroplasty for metal-on-metal failure.

Authors:  Justin S Chang; Fares S Haddad
Journal:  J Clin Orthop Trauma       Date:  2019-10-04

Review 3.  Wear of dual-mobility cups: a review article.

Authors:  Anna Di Laura; Harry Hothi; Clement Battisti; Arianna Cerquiglini; Johann Henckel; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-12-09       Impact factor: 3.075

4.  Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty.

Authors:  Craig W Forsthoefel; Nicholas M Brown; Mark L Barba
Journal:  J Orthop       Date:  2017-08-31

Review 5.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

6.  11-Year outcomes in patients with metal-on-metal ASR hip arthroplasty.

Authors:  Christian Bitar; Ivan Moberg; Ferid Krupic; Per Wretenberg; Volker Otten; Sead Crnalic
Journal:  J Orthop       Date:  2022-05-25

7.  Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature.

Authors:  Guillem Figueras; Ramón Vives Planell; Ramón Serra Fernàndez; Joan Camí Biayna
Journal:  Open Orthop J       Date:  2016-10-31

8.  Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007.

Authors:  S Bergiers; H S Hothi; J Henckel; A Eskelinen; J Skinner; A Hart
Journal:  Bone Joint Res       Date:  2018-12-01       Impact factor: 5.853

9.  The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue.

Authors:  Anna Di Laura; Paul D Quinn; Vasiliki C Panagiotopoulou; Harry S Hothi; Johann Henckel; Jonathan J Powell; Fitim Berisha; Fernanda Amary; J Fred W Mosselmans; John A Skinner; Alister J Hart
Journal:  Sci Rep       Date:  2017-09-08       Impact factor: 4.379

10.  Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement.

Authors:  Lari Lehtovirta; Aleksi Reito; Jyrki Parkkinen; Sirpa Peräniemi; Jouko Vepsäläinen; Antti Eskelinen
Journal:  PLoS One       Date:  2018-05-16       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.