Literature DB >> 26788016

PMMA microreactor for chemiluminescence detection of Cu (II) based on 1,10-Phenanthroline-hydrogen peroxide reaction.

Xueye Chen1, Jienan Shen1, Tiechuan Li1.   

Abstract

A microreactor for the chemiluminescence detection of copper (II) in water samples, based on the measurement of light emitted from the copper (II) catalysed oxidation of 1,10-phenanthroline by hydrogen peroxide in basic aqueous solution, is presented. Polymethyl methacrylate (PMMA) was chose as material for fabricating the microreactor with mill and hot bonding method. Optimized reagents conditions were found to be 6.3 × 10(-5)mol/L 1,10-phenanthroline, 1.5 × 10(-3)mol/L hydrogen peroxide, 7.0 × 10(-2)mol/L sodium hydroxide and 2.4 × 10(-5)mol/L Hexadecyl trimethyl ammonium Bromide (CTMAB). In the continuous flow injection mode the system can perform fully automated detection with a reagent consumption of only 3.5 μL each time. The linear range of the Cu (II) ions concentration was 1.5 × 10(-8) mol/L to 1.0 × 10(-4) mol/L, and the detection limit was 9.4 × 10(-9)mol/L with the S/N ratio of 4. The relative standard deviation was 3.0 % for 2.0 × 10(-6) mol/L Cu (II) ions (n = 10). The most obvious features of the detection method are simplicity, rapidity and easy fabrication of the microreactor.

Entities:  

Keywords:  1,10-phenanthroline; Chemiluminescence detection; Copper (II) ions; Microreactor

Year:  2015        PMID: 26788016      PMCID: PMC4711459          DOI: 10.1007/s13197-015-2034-6

Source DB:  PubMed          Journal:  J Food Sci Technol        ISSN: 0022-1155            Impact factor:   2.701


  7 in total

1.  Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay.

Authors:  Zhanjun Yang; Chen Zong; Huangxian Ju; Feng Yan
Journal:  Anal Chim Acta       Date:  2011-09-02       Impact factor: 6.558

2.  Enhancement of on chip chemiluminescence signal intensity of tris(1,10-phenanthroline)-ruthenium(II) peroxydisulphate system for analysis of chlorpheniramine maleate in pharmaceutical formulations.

Authors:  Haider A J Al Lawati; Fakhr Eldin O Suliman; Salma M Z Al Kindy; Ali M Al-Lawati; Gouri B Varma; Imad Eldin M Nour
Journal:  Talanta       Date:  2010-08-24       Impact factor: 6.057

3.  Determination of chromium(III) and total chromium using dual channels on glass chip with chemiluminescence detection.

Authors:  Waraporn Som-Aum; Jirasak Threeprom; Haifang Li; Jin-Ming Lin
Journal:  Talanta       Date:  2006-10-20       Impact factor: 6.057

4.  Passive micromixer for luminol-peroxide chemiluminescence detection.

Authors:  Khoi Seng Lok; Yien Chian Kwok; Nam-Trung Nguyen
Journal:  Analyst       Date:  2011-05-09       Impact factor: 4.616

5.  A chelate complex-enhanced luminol system for selective determination of Co(II), Fe(II) and Cr(III).

Authors:  Kyung Min Kim; Young Ho Kim; Sang-Hyub Oh; Sang Hak Lee
Journal:  Luminescence       Date:  2012-06-19       Impact factor: 2.464

6.  Metal ion analysis using microchip CE with chemiluminescence detection based on 1,10-phenanthroline-hydrogen peroxide reaction.

Authors:  Takahiro Nogami; Masahiko Hashimoto; Kazuhiko Tsukagoshi
Journal:  J Sep Sci       Date:  2009-02       Impact factor: 3.645

7.  A novel enzyme-immobilized flow cell used as end-column chemiluminescent detection interface in open-tubular capillary electrochromatography.

Authors:  Haoyue Xie; Zuorong Wang; Weijun Kong; Lin Wang; Zhifeng Fu
Journal:  Analyst       Date:  2013-02-21       Impact factor: 4.616

  7 in total