Literature DB >> 21552614

Passive micromixer for luminol-peroxide chemiluminescence detection.

Khoi Seng Lok1, Yien Chian Kwok, Nam-Trung Nguyen.   

Abstract

This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was investigated. The light intensity was detected using an optical fiber attached along the mixing channel and a photon detector. A linear correlation between chemiluminescence intensity and the concentration of cobalt(ii) ions or hydrogen peroxide was observed. This microchip has a potential application in environmental monitoring for industries involved in heavy metals and in medical diagnostics.

Entities:  

Year:  2011        PMID: 21552614     DOI: 10.1039/c1an15280g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  PMMA microreactor for chemiluminescence detection of Cu (II) based on 1,10-Phenanthroline-hydrogen peroxide reaction.

Authors:  Xueye Chen; Jienan Shen; Tiechuan Li
Journal:  J Food Sci Technol       Date:  2015-09-22       Impact factor: 2.701

2.  Rapid highly sensitive general protein quantification through on-chip chemiluminescence.

Authors:  Hoi Kei Chiu; Tadas Kartanas; Kadi L Saar; Carina Mouritsen Luxhøj; Sean Devenish; Tuomas P J Knowles
Journal:  Biomicrofluidics       Date:  2021-04-29       Impact factor: 2.800

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.