Literature DB >> 19173341

Metal ion analysis using microchip CE with chemiluminescence detection based on 1,10-phenanthroline-hydrogen peroxide reaction.

Takahiro Nogami1, Masahiko Hashimoto, Kazuhiko Tsukagoshi.   

Abstract

We developed a microchip CE method with chemiluminescence (CL) detection using the reaction of 1,10-phenanthroline and hydrogen peroxide for separation and determination of metal ions, where the metal ions acted as catalysts for the CL reaction. The microchip consisted of two microchannels that crossed at the intersection and four reservoirs that accessed the ends of the channels. The metal ions in the sample solution migrated in the channel along with 1,10-phenanthroline included in a running solution, and then mixed with hydrogen peroxide in one of the reservoirs to emit CL. The light was detected with a photomultiplier tube located just above the reservoir. Two metal ion groups, the platinum metal group (Ru(III), Rh(III), Pd(II), Os(VIII), Ir(III), and Pt(IV)) and the fourth periodic transition metal group (Cu(II), Fe(II), Co(II), and Ni(II)) were examined using the present system. The lowest detection limit was observed for Os(VIII); Os(VIII) responded over the range of 7.5x10(-12)-1.0x10(-8 )M with the detection limit of 7.5x10(-12 )M (about 38 zmol) (S/N = 3). The mixed solution of Ru(III), Rh(III), Pd(II), Os(VIII), Ir(III), and Pt(IV) could be analyzed using this system within about 2.5 min. In addition, the system was applied to the determination of Cu(II) concentration in a city water supply.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19173341     DOI: 10.1002/jssc.200800448

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  PMMA microreactor for chemiluminescence detection of Cu (II) based on 1,10-Phenanthroline-hydrogen peroxide reaction.

Authors:  Xueye Chen; Jienan Shen; Tiechuan Li
Journal:  J Food Sci Technol       Date:  2015-09-22       Impact factor: 2.701

Review 2.  Tailoring photosensitive ROS for advanced photodynamic therapy.

Authors:  Duc Loc Sai; Jieun Lee; Duc Long Nguyen; Young-Pil Kim
Journal:  Exp Mol Med       Date:  2021-04-08       Impact factor: 8.718

3.  A high sensitivity micro format chemiluminescence enzyme inhibition assay for determination of Hg(II).

Authors:  Kanchanmala Deshpande; Rupesh K Mishra; Sunil Bhand
Journal:  Sensors (Basel)       Date:  2010-06-28       Impact factor: 3.576

Review 4.  A Review of Optical Imaging Technologies for Microfluidics.

Authors:  Pan Zhou; Haipeng He; Hanbin Ma; Shurong Wang; Siyi Hu
Journal:  Micromachines (Basel)       Date:  2022-02-08       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.