Literature DB >> 26785310

Label-free signal-on aptasensor for sensitive electrochemical detection of arsenite.

Lin Cui1, Jie Wu1, Huangxian Ju2.   

Abstract

A signal-on aptasensor was fabricated for highly sensitive and selective electrochemical detection of arsenite with a label-free Ars-3 aptamer self-assembled on a screen-printed carbon electrode (SPCE) via Au-S bond. The Ars-3 aptamer could adsorb cationic polydiallyldimethylammonium (PDDA) via electrostatic interaction to repel other cationic species. In the presence of arsenite, the change of Ars-3 conformation due to the formation of Ars-3/arsenite complex led to less adsorption of PDDA, and the complex could adsorb more positively charged [Ru(NH3)6](3+) as an electrochemically active indicator on the aptasensor surface, which produced a sensitive "turn-on" response. The target-induced structure switching could be used for sensitive detection of arsenite with a linear range from 0.2 nM to 100 nM and a detection limit down to 0.15 nM. Benefiting from Ars-3 aptamer, the proposed system exhibited excellent specificity against other heavy metal ions. The SPCE-based aptasensor exhibited the advantages of low cost and simple fabrication, providing potential application of arsenite detection in environment.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Aptasensor; Arsenite; Electrochemical sensor; Screen-printed carbon electrode

Mesh:

Substances:

Year:  2016        PMID: 26785310     DOI: 10.1016/j.bios.2016.01.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

1.  Impedimetric PSA aptasensor based on the use of a glassy carbon electrode modified with titanium oxide nanoparticles and silk fibroin nanofibers.

Authors:  Ali Benvidi; Maryam Banaei; Marzieh Dehghan Tezerjani; Hosein Molahosseini; Shahriar Jahanbani
Journal:  Mikrochim Acta       Date:  2017-12-14       Impact factor: 5.833

2.  A Schiff base modified graphene oxide film for anodic stripping voltammetric determination of arsenite.

Authors:  Ranjeet Kaur; Shweta Rana; Raghubir Singh; Varinder Kaur; Priyanka Narula
Journal:  Mikrochim Acta       Date:  2019-11-04       Impact factor: 5.833

Review 3.  From Small Molecules Toward Whole Cells Detection: Application of Electrochemical Aptasensors in Modern Medical Diagnostics.

Authors:  Robert Ziółkowski; Marta Jarczewska; Łukasz Górski; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-01-21       Impact factor: 3.576

4.  A Facile Aptasensor for Instantaneous Determination of Cadmium Ions Based on Fluorescence Amplification Effect of MOPS on FAM-Labeled Aptamer.

Authors:  Yang Liu; Dongwei Zhang; Jina Ding; Kashif Hayat; Xijia Yang; Xuejia Zhan; Dan Zhang; Yitong Lu; Pei Zhou
Journal:  Biosensors (Basel)       Date:  2021-04-23

5.  Silica and graphene mediate arsenic detection in mature rice grain by a newly patterned current-volt aptasensor.

Authors:  M N A Uda; Subash C B Gopinath; Uda Hashim; N H Halim; N A Parmin; M N Afnan Uda; Tijjani Adam; Periasamy Anbu
Journal:  Sci Rep       Date:  2021-07-19       Impact factor: 4.379

Review 6.  Portable Bio/Chemosensoristic Devices: Innovative Systems for Environmental Health and Food Safety Diagnostics.

Authors:  Roberto Dragone; Gerardo Grasso; Michele Muccini; Stefano Toffanin
Journal:  Front Public Health       Date:  2017-05-05

7.  Aptamer-Based Impedimetric Assay of Arsenite in Water: Interfacial Properties and Performance.

Authors:  Karlene Vega-Figueroa; Jaime Santillán; Valerie Ortiz-Gómez; Edwin O Ortiz-Quiles; Beatriz A Quiñones-Colón; David A Castilla-Casadiego; Jorge Almodóvar; Marvin J Bayro; José A Rodríguez-Martínez; Eduardo Nicolau
Journal:  ACS Omega       Date:  2018-02-02

Review 8.  Electrochemical Aptasensors for Food and Environmental Safeguarding: A Review.

Authors:  Geetesh Kumar Mishra; Vinay Sharma; Rupesh K Mishra
Journal:  Biosensors (Basel)       Date:  2018-03-23

9.  Calix[4]arene Derivative-Modified Glassy Carbon Electrode: A New Sensing Platform for Rapid, Simultaneous, and Picomolar Detection of Zn(II), Pb(II), As(III), and Hg(II).

Authors:  Sundus Sultan; Afzal Shah; Burhan Khan; Jan Nisar; Muhammad Raza Shah; Muhammad Naeem Ashiq; Mohammad Salim Akhter; Aamir Hassan Shah
Journal:  ACS Omega       Date:  2019-10-04

Review 10.  Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources.

Authors:  Wei Zhang; Qing Xiu Liu; Zhi Hou Guo; Jun Sheng Lin
Journal:  Molecules       Date:  2018-02-07       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.