Literature DB >> 31686225

A Schiff base modified graphene oxide film for anodic stripping voltammetric determination of arsenite.

Ranjeet Kaur1, Shweta Rana1, Raghubir Singh2, Varinder Kaur3, Priyanka Narula1.   

Abstract

A protocol is described for chemical modification of graphene oxide with a Schiff base derived from diethylenetriamine and 2-hydroxy-4-methoxybenzophenone. The base was grafted onto an indium tin oxide (ITO) film and applied to electroanalytical determination of arsenite. Successful grafting was confirmed by Fourier transform-infrared spectroscopy, spectrophotometry, field emission scanning electron microscopy and cyclic voltammetry. Secondly, the coated ITO film served as a working electrode for the stripping voltammetric determination of arsenite. The analytical signal is generated by selective oxidation of metal species via multi-donor sites present in the derivatized Schiff base. The electroanalytical protocol was optimized by investigating the effects of deposition time, working potential, frequency and amplitude of square wave anodic stripping voltammetry. The method has attractive features including (a) the usage of a non-metallic, non-toxic and cost-effective material; (b) improved sensitivity (with limit of detection as low as 156 pM) due to better adsorption of arsenite in the Schiff base pockets on the ITO, and (c) the application to the determination of arsenite in real samples. Graphical abstract Schematic representation of the fabrication of a Schiff base-functionalized graphene oxide on an indium tin oxide (SB@SiO2@GO@ITO) electrode for selective electrochemical sensing of arsenite due to adsorption on multi-donor sites.

Entities:  

Keywords:  2-Hydroxybenzophenone; As(III); Azomethine; Chronocoulometry; Environmental analysis; Metallic toxin; Oxyanion; Portable electrodes; Silatrane; Voltammetry

Year:  2019        PMID: 31686225     DOI: 10.1007/s00604-019-3807-9

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  17 in total

1.  Graphene oxide as a stationary phase for speciation of inorganic and organic species of mercury, arsenic and selenium using HPLC with ICP-MS detection.

Authors:  Heyong Cheng; Wenwen Zhang; Yuanchao Wang; Jinhua Liu
Journal:  Mikrochim Acta       Date:  2018-08-22       Impact factor: 5.833

2.  Speciation and detection of arsenic in aqueous samples: a review of recent progress in non-atomic spectrometric methods.

Authors:  Jian Ma; Mrinal K Sengupta; Dongxing Yuan; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2014-04-23       Impact factor: 6.558

3.  The electrochemical oxidation of troxerutin and its sensitive determination in pharmaceutical dosage forms at PVP modified carbon paste electrode.

Authors:  Xiaofeng Yang; Fang Wang; Shengshui Hu
Journal:  Colloids Surf B Biointerfaces       Date:  2006-06-03       Impact factor: 5.268

Review 4.  The global menace of arsenic and its conventional remediation - A critical review.

Authors:  Arpan Sarkar; Biswajit Paul
Journal:  Chemosphere       Date:  2016-05-28       Impact factor: 7.086

Review 5.  A review on endocrine disruptors and their possible impacts on human health.

Authors:  Eva Rahman Kabir; Monica Sharfin Rahman; Imon Rahman
Journal:  Environ Toxicol Pharmacol       Date:  2015-06-09       Impact factor: 4.860

Review 6.  Human health implications, risk assessment and remediation of As-contaminated water: A critical review.

Authors:  Muhammad Bilal Shakoor; Rab Nawaz; Fida Hussain; Maimoona Raza; Shafaqat Ali; Muhammad Rizwan; Sang-Eun Oh; Sajjad Ahmad
Journal:  Sci Total Environ       Date:  2017-06-01       Impact factor: 7.963

7.  Electrochemical detection of arsenic(III) completely free from noble metal: Fe3O4 microspheres-room temperature ionic liquid composite showing better performance than gold.

Authors:  Chao Gao; Xin-Yao Yu; Shi-Quan Xiong; Jin-Huai Liu; Xing-Jiu Huang
Journal:  Anal Chem       Date:  2013-02-15       Impact factor: 6.986

8.  Speciation Analysis of Arsenic Compounds by HPLC-ICP-MS: Application for Human Serum and Urine.

Authors:  Manh Ha Nguyen; Tien Duc Pham; Thi Lien Nguyen; Hai Anh Vu; Thi Thao Ta; Minh Binh Tu; Thi Hong Yen Nguyen; Dinh Binh Chu
Journal:  J Anal Methods Chem       Date:  2018-11-13       Impact factor: 2.193

9.  Facile Synthesis of β-Lactoglobulin-Functionalized Reduced Graphene Oxide and Trimetallic PtAuPd Nanocomposite for Electrochemical Sensing.

Authors:  Bingkai Han; Meixin Pan; Jiexin Zhou; Yingying Wang; Zihua Wang; Jun Jiao; Cong Zhang; Qiang Chen
Journal:  Nanomaterials (Basel)       Date:  2018-09-13       Impact factor: 5.076

10.  Electrochemical Sensing toward Trace As(III) Based on Mesoporous MnFe₂O₄/Au Hybrid Nanospheres Modified Glass Carbon Electrode.

Authors:  Shaofeng Zhou; Xiaojuan Han; Honglei Fan; Yaqing Liu
Journal:  Sensors (Basel)       Date:  2016-06-22       Impact factor: 3.576

View more
  1 in total

1.  Solvent Influence on Absorption Spectra and Tautomeric Equilibria of Symmetric Azomethine-Functionalized Derivatives: Structural Elucidation and Computational Studies.

Authors:  Kifah S M Salih
Journal:  ChemistryOpen       Date:  2022-02       Impact factor: 2.911

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.