(13)C mixed triglyceride breath testing using infrared spectrometry: comparison of two devices in early infancy.

D S Kent1, T Remer2, C Blumenthal1,3, K J Gaskin1.   

Abstract

BACKGROUND/
OBJECTIVES: The (13)C mixed triglyceride (MTG) breath test has been proposed for the non-invasive assessment of fat digestion and absorption. To evaluate whether reference values for the adequacy of fat absorption, set in the non-dispersive infrared spectrometry (NDIRS) system software proposed for healthy children and adults using the (13)C MTG breath test, are also applicable to infants of <5 months of age. SUBJECTS/
METHODS: (13)C MTG breath testing with the NDIRS technique was performed in 54 healthy infants <5 months of age (38 breast-fed, 16 formula-fed) and six infants diagnosed with cystic fibrosis (CF) using two NDIRS devices, IRIS and FANci2.
RESULTS: The IRIS results were slightly higher compared with those assessed by the FANci2 device. The minimum cutoff value for pancreatic sufficiency (PS) is set as a cumulative percentage dose of (13)C recovered (cPDR) after 5 h of 13.0%. Pancreatic function status of six CF infants, three with PS and three with pancreatic insufficiency (PI), according to the 72 h-faecal fat balance test could be correctly determined with the (13)C MTG breath test using two NDIRS techniques. However, if these reference values had been used to determine pancreatic function status in healthy infants, 26 out of 54 infants would have been misclassified as pancreatic insufficient.
CONCLUSIONS: Although the (13)C MTG breath test with the MS technique has the potential to be a suitable assessment of fat absorption in infants, the technique of NDIRS appears too insensitive in an infant population group.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26757839     DOI: 10.1038/ejcn.2015.228

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  16 in total

1.  A modified ¹³C-mixed triglyceride breath test detects moderate pancreatic exocrine insufficiency.

Authors:  Jutta Keller; Sebastian Brückel; Christine Jahr; Peter Layer
Journal:  Pancreas       Date:  2011-11       Impact factor: 3.327

2.  13Carbon mixed triglyceride breath test and pancreatic enzyme supplementation in cystic fibrosis.

Authors:  S Amarri; M Harding; W A Coward; T J Evans; L T Weaver
Journal:  Arch Dis Child       Date:  1997-04       Impact factor: 3.791

3.  Evaluation studies of the 13C-mixed triglyceride breath test in healthy controls and adult cystic fibrosis patients with exocrine pancreatic insufficiency.

Authors:  G R Swart; E A Baartman; J L Wattimena; T Rietveld; S E Overbeek; J W van den Berg
Journal:  Digestion       Date:  1997       Impact factor: 3.216

4.  13C mixed triglyceride breath test: a noninvasive method to assess lipase activity in children.

Authors:  K van Dijk-van Aalst; M Van Den Driessche; S van Der Schoor; S Schiffelers; T van't Westeinde; Y Ghoos; G Veereman-Wauters
Journal:  J Pediatr Gastroenterol Nutr       Date:  2001-05       Impact factor: 2.839

5.  [13C-mixed triglyceride CO2 exhalation test. Investigation with an isotope selective, non dispersive infrared spectrophotometer of indirect function of the exocrine pancreas].

Authors:  R J Adamek; C Bödeker; C Szymanski; D Hagemann; B Pfaffenbach
Journal:  Dtsch Med Wochenschr       Date:  1999-02-05       Impact factor: 0.628

6.  Clinically feasible stable isotope technique at a reasonable price: analysis of 13CO2/12CO2-abundance in breath samples with a new isotope selective-nondispersive infrared spectrometer.

Authors:  B Braden; M Haisch; L P Duan; B Lembcke; W F Caspary; P Hering
Journal:  Z Gastroenterol       Date:  1994-12       Impact factor: 2.000

7.  13C-labeled mixed triglyceride breath test (13C MTG-BT) in healthy children and children with cystic fibrosis (CF) under pancreatic enzyme replacement therapy (PERT): a pilot study.

Authors:  Denise C Herzog; Edgard E Delvin; Caroline Albert; Jacques E Marcotte; Véronique A Pelletier; Ernest G Seidman
Journal:  Clin Biochem       Date:  2008-09-16       Impact factor: 3.281

8.  Diagnosis and differentiation of fat malabsorption in children using 13C-labeled lipids: trioctanoin, triolein, and palmitic acid breath tests.

Authors:  J B Watkins; P D Klein; D A Schoeller; B S Kirschner; R Park; J A Perman
Journal:  Gastroenterology       Date:  1982-05       Impact factor: 22.682

9.  Normative values for the 13C-mixed triglyceride breath test in two age groups.

Authors:  Krzysztof Jonderko; Zuzanna Duś; Małgorzata Szymszal; Anna Kasicka-Jonderko; Barbara Błońska-Fajfrowska
Journal:  Med Sci Monit       Date:  2009-05

10.  Mixed triglyceride breath test: a noninvasive test of pancreatic lipase activity in the duodenum.

Authors:  G R Vantrappen; P J Rutgeerts; Y F Ghoos; M I Hiele
Journal:  Gastroenterology       Date:  1989-04       Impact factor: 22.682