Literature DB >> 19396042

Normative values for the 13C-mixed triglyceride breath test in two age groups.

Krzysztof Jonderko1, Zuzanna Duś, Małgorzata Szymszal, Anna Kasicka-Jonderko, Barbara Błońska-Fajfrowska.   

Abstract

BACKGROUND: To investigate if age affects the results of the 13C-mixed triglyceride (13C-MTG) breath test. MATERIAL/
METHODS: Two groups of 12 healthy subjects (group Y, 25.0+/-0.7 years; group MA, 48.8+/-2.4 years), each comprising 6 men and 6 women, were examined. The fasted volunteers had a 349-kcal test breakfast of 50 g of white bread with 30 g of butter to which 300 mg of 13C-MTG was added. Then a series of samples of exhaled air for the measurement of 13CO2 concentration was collected over a period of 9 hours.
RESULTS: A maximum momentary 13CO2 breath excretion of 9.6+/-0.5%dose/h at 295+/-19 min in the young subjects and of 9.4+/-0.4%dose/h at 270+/-15 min in the middle-aged volunteers was observed. The group curves of cumulative 13C recovery in breath air exhibited a virtually overlapping time course. The 6-h cumulative 13C recovery amounted to 32.01+/-1.78%dose and 31.84+/-1.73%dose in the Y and MA groups, respectively. Extension of the collection of breath air samples from the standard six to nine hours resulted in an increase in the cumulative 13C recovery by 51.5+/-3.2%. Accordingly, the 9-h cumulative 13C recovery was 47.59+/-2.26%dose and 48.28+/-2.36%dose in the Y and MA groups, respectively.
CONCLUSIONS: An age difference of over two decades does not compromise intrajejunal lipolytic activity taken as a measure of pancreatic exocrine function. Therefore reference values for the 13C-MTG breath test can be obtained from a population of healthy subjects of a relatively wide age range.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19396042

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


  4 in total

1.  (13)C mixed triglyceride breath testing using infrared spectrometry: comparison of two devices in early infancy.

Authors:  D S Kent; T Remer; C Blumenthal; K J Gaskin
Journal:  Eur J Clin Nutr       Date:  2016-01-13       Impact factor: 4.016

2.  Diagnosis of Exocrine Pancreatic Insufficiency.

Authors:  Phil A Hart; Darwin L Conwell
Journal:  Curr Treat Options Gastroenterol       Date:  2015-09

3.  C-methacetin breath test reproducibility study reveals persistent CYP1A2 stimulation on repeat examinations.

Authors:  Anna Kasicka-Jonderko; Anna Nita; Krzysztof Jonderko; Magdalena Kamińska; Barbara Błońska-Fajfrowska
Journal:  World J Gastroenterol       Date:  2011-12-07       Impact factor: 5.742

Review 4.  European guideline on indications, performance and clinical impact of 13 C-breath tests in adult and pediatric patients: An EAGEN, ESNM, and ESPGHAN consensus, supported by EPC.

Authors:  Jutta Keller; Heinz F Hammer; Paul R Afolabi; Marc Benninga; Osvaldo Borrelli; Enrique Dominguez-Munoz; Dan Dumitrascu; Oliver Goetze; Stephan L Haas; Bruno Hauser; Daniel Pohl; Silvia Salvatore; Marc Sonyi; Nikhil Thapar; Kristin Verbeke; Mark R Fox
Journal:  United European Gastroenterol J       Date:  2021-06-14       Impact factor: 4.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.