Literature DB >> 11429520

13C mixed triglyceride breath test: a noninvasive method to assess lipase activity in children.

K van Dijk-van Aalst1, M Van Den Driessche, S van Der Schoor, S Schiffelers, T van't Westeinde, Y Ghoos, G Veereman-Wauters.   

Abstract

BACKGROUND: Results from the 13C mixed triglyceride (MTG) breath test correlate with duodenal lipase activity in adults. This noninvasive test is a potential screening and diagnostic tool for children with fat malabsorption. The aim of this study was to adapt the methodology of the MTG breath test to study test meals and sampling methods and to define normal values for healthy children of all age groups; premature and full-term infants have similar pancreatic lipase deficiencies.
METHODS: After parental consent was obtained, 12 premature infants (< 37 weeks gestation and with body weights > 2 kg), 12 full-term infants (1-6 months old), 20 children (3-10 years old), and 20 teenagers (11-17 years old) were tested. All children were thriving well, had no gastrointestinal or respiratory problems, and had not received any medication that contained natural 13C. For the premature and full-term infants, a formula was prepared that had a low and stable natural 13C content mixed with 100 mg 13C-labeled MTG (1,3-distearyl, 2-[13C-carboxyl] octanoyl glycerol) and 1 g polyethylene-glycol 3350. The best accepted test meal for children over 3 years old was a slice of white bread with 5 g butter and 15 g chocolate paste, mixed with 250 mg 13C-labeled MTG, and a glass of 100 mL whole-fat milk. Children over 3 years old were able to blow through a straw in a vacutainer for collecting the breath samples. In children under 3 years old, expired air was collected by aspirating breath via a nasal prong. Carbon dioxide production was calculated according to weight, age, and sex.
RESULTS: For healthy pediatric control participants, the mean values for cumulative excretion of 13CO2 as a percentage of the administered dose after 6 hours were 23.9 +/- 5.2% in premature infants, 31.9 +/- 7.7% in full-term infants, 32.5 +/- 5.3% in children, and 28.0 +/- 5.4% in teenagers. The mean value for healthy adults is 35.6% with a lower reference limit of 22.8%.
CONCLUSIONS: Age-specific test meals and breath-sampling techniques for the MTG breath test were defined. The mean values for different age groups may serve as guidelines for normal values in the pediatric population. The cumulative values for expired 13CO2 were above the lower limit for adults, which suggests that preduodenal lipases compensates for pancreatic lipase deficiency in premature and full-term infants.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11429520     DOI: 10.1097/00005176-200105000-00017

Source DB:  PubMed          Journal:  J Pediatr Gastroenterol Nutr        ISSN: 0277-2116            Impact factor:   2.839


  6 in total

Review 1.  Chronic Pancreatitis: Current Status and Challenges for Prevention and Treatment.

Authors:  Daniel Lew; Elham Afghani; Stephen Pandol
Journal:  Dig Dis Sci       Date:  2017-05-13       Impact factor: 3.199

2.  (13)C mixed triglyceride breath testing using infrared spectrometry: comparison of two devices in early infancy.

Authors:  D S Kent; T Remer; C Blumenthal; K J Gaskin
Journal:  Eur J Clin Nutr       Date:  2016-01-13       Impact factor: 4.016

3.  Malabsorption blood test: Assessing fat absorption in patients with cystic fibrosis and pancreatic insufficiency.

Authors:  Maria R Mascarenhas; John Mondick; Jeffrey S Barrett; Martha Wilson; Virginia A Stallings; Joan I Schall
Journal:  J Clin Pharmacol       Date:  2015-03-23       Impact factor: 3.126

4.  Lysine kinetics in preterm infants: the importance of enteral feeding.

Authors:  S R D van der Schoor; P J Reeds; F Stellaard; J D L Wattimena; P J J Sauer; H A Büller; J B van Goudoever
Journal:  Gut       Date:  2004-01       Impact factor: 23.059

5.  Estimation of postoperative fat absorption using the 13C mixed-triglyceride breath test in children with choledochal cyst.

Authors:  Mitsuyoshi Suzuki; Kyoko Tanaka; Kiyotaka Ohtani; Kazuhiro Kitamura; Takahiro Kudo; Hiromichi Shoji; Ryuyo Suzuki; Toshiaki Shimizu
Journal:  Eur J Pediatr       Date:  2008-04-01       Impact factor: 3.183

Review 6.  European guideline on indications, performance and clinical impact of 13 C-breath tests in adult and pediatric patients: An EAGEN, ESNM, and ESPGHAN consensus, supported by EPC.

Authors:  Jutta Keller; Heinz F Hammer; Paul R Afolabi; Marc Benninga; Osvaldo Borrelli; Enrique Dominguez-Munoz; Dan Dumitrascu; Oliver Goetze; Stephan L Haas; Bruno Hauser; Daniel Pohl; Silvia Salvatore; Marc Sonyi; Nikhil Thapar; Kristin Verbeke; Mark R Fox
Journal:  United European Gastroenterol J       Date:  2021-06-14       Impact factor: 4.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.