Literature DB >> 2675184

Cemented total hip prosthesis: radiographic and scintigraphic evaluation.

P Aliabadi1, S S Tumeh, B N Weissman, B J McNeil.   

Abstract

Conventional radiographs, technetium-99m bone scans, and gallium-67 scans were reviewed in 44 patients who had undergone cemented total hip joint replacement and were imaged because of suspicion of prosthesis loosening or infection. A complete radiolucent line of 2 mm or wider along the bone-cement interface or metal-cement lucency on conventional radiographs was used as the criterion for prosthetic loosening with or without infection and proved to be 54% sensitive and 96% specific. Scintigraphic criteria for prosthetic loosening were increased focal uptake of the radiopharmaceutical for the femoral component and increased focal or diffuse uptake for the acetabular component. For bone scintigraphy, sensitivity was 73% and specificity was 96%. Combining the results of conventional radiographs and bone scans increased sensitivity to 84% and decreased specificity to 92% for the diagnosis of loosening, infection, or both. The study also showed that Ga-67 scintigraphy has a low sensitivity for the detection of infection.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2675184     DOI: 10.1148/radiology.173.1.2675184

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Role of routine percutaneous hip aspirations prior to prosthesis revision.

Authors:  E S Gould; H G Potter; S E Bober
Journal:  Skeletal Radiol       Date:  1990       Impact factor: 2.199

2.  White blood cell scintigraphy with monoclonal antibodies in the study of the infected endoprosthesis.

Authors:  J Sciuk; C Puskás; B Greitemann; O Schober
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Imaging near orthopedic hardware.

Authors:  Matthew F Koff; Alissa J Burge; Kevin M Koch; Hollis G Potter
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

4.  What is the role of magnetic resonance imaging in the evaluation of total hip arthroplasty?

Authors:  Hollis G Potter; Li F Foo; Bryan J Nestor
Journal:  HSS J       Date:  2005-09

5.  CORR Insights®: What is the Diagnostic Accuracy of MRI for Component Loosening in THA?

Authors:  H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

6.  [Importance of SPECT/CT for knee and hip joint prostheses].

Authors:  K Strobel; I Steurer-Dober; M W Huellner; P Veit-Haibach; B Allgayer
Journal:  Radiologe       Date:  2012-07       Impact factor: 0.635

7.  The value of Tc-99m Nanocolloid scintigraphy in the evaluation of infected total hip arthroplasties.

Authors:  I Bernay; M Akinci; M Kitapçi; N Tokgözoglu; G Erbengi
Journal:  Ann Nucl Med       Date:  1993-11       Impact factor: 2.668

8.  Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses.

Authors:  A Boubaker; A B Delaloye; C H Blanc; M Dutoit; P F Leyvraz; B Delaloye
Journal:  Eur J Nucl Med       Date:  1995-02

Review 9.  [Imaging of hip joint arthroplasty].

Authors:  M E Mayerhoefer; J Frühwald-Pallamar; C Czerny
Journal:  Radiologe       Date:  2009-05       Impact factor: 0.635

Review 10.  Nuclear medicine and the failed joint replacement: Past, present, and future.

Authors:  Christopher J Palestro
Journal:  World J Radiol       Date:  2014-07-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.