Literature DB >> 26742125

Computer-Assisted Screw Size and Insertion Trajectory Planning for Pedicle Screw Placement Surgery.

Dejan Knez, Bostjan Likar, Franjo Pernus, Tomaz Vrtovec.   

Abstract

Pathological conditions that cause instability of the spine are commonly treated by vertebral fixation involving pedicle screw placement surgery. However, existing methods for preoperative planning are based only on geometrical properties of vertebral structures (i.e., shape) without taking into account their structural properties (i.e., appearance). We propose a novel automated method for computer-assisted preoperative planning of the thoracic pedicle screw size and insertion trajectory. The proposed method extracts geometrical properties of vertebral structures by parametric modeling of vertebral bodies and pedicles in three dimensions (3D), and combines them with structural properties, evaluated through underlying image intensities in computed tomography (CT) images while considering the guidelines for pedicle screw design. The method was evaluated on 81 pedicles, obtained from 3D CT images of 11 patients that were appointed for pedicle screw placement surgery. In terms of mean absolute difference (MAD) and corresponding standard deviation (SD), the resulting high modeling accuracy of 0.39±0.31 mm for 3D vertebral body models and 0.31±0.25 mm for 3D pedicle models created an adequate anatomical frame for 3D pedicle screw models. When comparing the automatically obtained and manually defined plans for pedicle screw placement, a relatively high agreement was observed, with MAD ±SD of 0.4±0.4 mm for the screw diameter, 5.8±4.2 mm for the screw length, 2.0±1.4 mm for the pedicle crossing point and 7.6±5.8(°) for screw insertion angles. However, a statistically significant increase of 48±26% in the screw fastening strength in favor of the proposed automated method was observed in 99% of the cases.

Entities:  

Mesh:

Year:  2016        PMID: 26742125     DOI: 10.1109/TMI.2016.2514530

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  Automatic detection of vertebral number abnormalities in body CT images.

Authors:  Shouhei Hanaoka; Yoshiyasu Nakano; Mitsutaka Nemoto; Yukihiro Nomura; Tomomi Takenaga; Soichiro Miki; Takeharu Yoshikawa; Naoto Hayashi; Yoshitaka Masutani; Akinobu Shimizu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

2.  Robotic drill guide positioning using known-component 3D-2D image registration.

Authors:  Thomas Yi; Vignesh Ramchandran; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06

3.  Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration.

Authors:  J Goerres; A Uneri; M Jacobson; B Ramsay; T De Silva; M Ketcha; R Han; A Manbachi; S Vogt; G Kleinszig; J-P Wolinsky; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

4.  Spinal pedicle screw planning using deformable atlas registration.

Authors:  J Goerres; A Uneri; T De Silva; M Ketcha; S Reaungamornrat; M Jacobson; S Vogt; G Kleinszig; G Osgood; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-02-08       Impact factor: 4.174

5.  Automatic pedicle screw planning using atlas-based registration of anatomy and reference trajectories.

Authors:  R Vijayan; T De Silva; R Han; X Zhang; A Uneri; S Doerr; M Ketcha; A Perdomo-Pantoja; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-08-21       Impact factor: 4.174

6.  Atlas-based automatic planning and 3D-2D fluoroscopic guidance in pelvic trauma surgery.

Authors:  R Han; A Uneri; T De Silva; M Ketcha; J Goerres; S Vogt; G Kleinszig; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-05-02       Impact factor: 4.174

7.  Use of the sagittal Cobb* angle to guide the rod bending in the treatment of thoracolumbar fractures: a retrospective clinical study.

Authors:  Zongpo Shi; Gang Wang; Zhen Jin; Tao Wu; Haoran Wang; Jinpeng Sun; Yap San Min Nicolas; K C Rupesh; Kaixiang Yang; Jun Liu
Journal:  J Orthop Surg Res       Date:  2020-12-01       Impact factor: 2.359

8.  Heterotopic Ossification After Prestige-LP Cervical Disc Arthroplasty Is Related to Insufficient Sagittal Coverage of the Endplate By the Prosthesis.

Authors:  Shuai Xu; Yunsheng Ou; Xing Du; Bin He; Yuanqiang Li; Haoyang Yu
Journal:  Med Sci Monit       Date:  2021-03-22

9.  The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study.

Authors:  Jia Bin Liu; Rui Zuo; Wen Jie Zheng; Chang Qing Li; Chao Zhang; Yue Zhou
Journal:  BMC Musculoskelet Disord       Date:  2022-02-21       Impact factor: 2.362

10.  Multi-scanner and multi-modal lumbar vertebral body and intervertebral disc segmentation database.

Authors:  Yasmina Al Khalil; Edoardo A Becherucci; Jan S Kirschke; Dimitrios C Karampinos; Marcel Breeuwer; Thomas Baum; Nico Sollmann
Journal:  Sci Data       Date:  2022-03-23       Impact factor: 6.444

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.