Literature DB >> 26730689

Outcomes of Varus Valgus Constrained Versus Rotating-Hinge Implants in Total Knee Arthroplasty.

Tennison L Malcolm, S Samuel Bederman, Ran Schwarzkopf.   

Abstract

The stability of a total knee arthroplasty is determined by the ability of the prosthesis components in concert with supportive bone and soft tissue structures to sufficiently resist deforming forces transmitted across the knee joint. Constrained prostheses are used in unstable knees due to their ability to resist varus and valgus transformative forces across the knee. Constraint requires inherent rigidity, which can facilitate early implant failure. The purpose of this study was to describe the comparative indications for surgery and postoperative outcomes of varus valgus constrained knee (VVK) and rotating-hinge knee (RHK) total knee arthroplasty prostheses. Seven retrospective observational studies describing 544 VVK and 254 RHK patients with an average follow-up of 66 months (range, 7-197 months) were evaluated. Patients in both groups experienced similar failure rates (P=.74), ranges of motion (P=.81), and Knee Society function scores (P=.29). Average Knee Society knee scores were 4.2 points higher in VVK patients compared with RHK patients, indicating minimal mid-term clinical differences may exist (P<.0001). Absent collateral ligament support is an almost universal indication for RHK implantation vs VVK. Constrained device implantation is routinely guided by inherent stability of the knee, and, when performed, similar postoperative outcomes can be achieved with VVK and RHK prostheses. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 26730689     DOI: 10.3928/01477447-20151228-07

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  6 in total

1.  Guided-motion hinged knee replacement prosthesis: early survival rate and postoperative patient function and satisfaction.

Authors:  David L Perrin; Thomas R Turgeon
Journal:  Can J Surg       Date:  2020-05-01       Impact factor: 2.089

2.  Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty.

Authors:  Jason Beng Teck Lim; Hee Nee Pang; Keng Jin Darren Tay; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-12-16

3.  Good clinical and radiological results of total knee arthroplasty using varus valgus constrained or rotating hinge implants in ligamentous laxity.

Authors:  Eric Röhner; Kathrin Benad; Timo Zippelius; Nadja Kloss; Benjamin Jacob; Julia Kirschberg; Georg Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-11-20       Impact factor: 4.342

4.  Constraint choice in revision knee arthroplasty: study protocol of a randomised controlled trial assessing the effect of level of constraint on postoperative outcome.

Authors:  Hagen Hommel; Kai Wilke; Daniel Kunze; Peggy Hommel; Peter Fennema
Journal:  BMJ Open       Date:  2017-03-27       Impact factor: 2.692

5.  Rotating hinge knee versus constrained condylar knee in revision total knee arthroplasty: A meta-analysis.

Authors:  Jung-Ro Yoon; Ji-Young Cheong; Jung-Taek Im; Phil-Sun Park; Jae-Ok Park; Young-Soo Shin
Journal:  PLoS One       Date:  2019-03-25       Impact factor: 3.240

6.  Long-term outcomes of one single-design varus valgus constrained versus one single-design rotating hinge in revision knee arthroplasty after over 10-year follow-up.

Authors:  Pablo Sanz-Ruiz; Víctor Estuardo León-Román; José Antonio Matas-Diez; Manuel Villanueva-Martínez; Javier Vaquero
Journal:  J Orthop Surg Res       Date:  2022-03-04       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.