Literature DB >> 26685227

Relaxed Linearized Algorithms for Faster X-Ray CT Image Reconstruction.

Hung Nien, Jeffrey A Fessler.   

Abstract

Statistical image reconstruction (SIR) methods are studied extensively for X-ray computed tomography (CT) due to the potential of acquiring CT scans with reduced X-ray dose while maintaining image quality. However, the longer reconstruction time of SIR methods hinders their use in X-ray CT in practice. To accelerate statistical methods, many optimization techniques have been investigated. Over-relaxation is a common technique to speed up convergence of iterative algorithms. For instance, using a relaxation parameter that is close to two in alternating direction method of multipliers (ADMM) has been shown to speed up convergence significantly. This paper proposes a relaxed linearized augmented Lagrangian (AL) method that shows theoretical faster convergence rate with over-relaxation and applies the proposed relaxed linearized AL method to X-ray CT image reconstruction problems. Experimental results with both simulated and real CT scan data show that the proposed relaxed algorithm (with ordered-subsets [OS] acceleration) is about twice as fast as the existing unrelaxed fast algorithms, with negligible computation and memory overhead.

Entities:  

Mesh:

Year:  2015        PMID: 26685227      PMCID: PMC4821734          DOI: 10.1109/TMI.2015.2508780

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  17 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

Authors:  Jang Hwan Cho; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10-28       Impact factor: 10.048

3.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

6.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

7.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

8.  Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction.

Authors:  Donghwan Kim; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-08-22       Impact factor: 10.048

9.  Fast X-ray CT image reconstruction using a linearized augmented Lagrangian method with ordered subsets.

Authors:  Hung Nien; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-09-16       Impact factor: 10.048

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  5 in total

1.  SPULTRA: Low-Dose CT Image Reconstruction With Joint Statistical and Learned Image Models.

Authors:  Siqi Ye; Saiprasad Ravishankar; Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

2.  Image reconstruction for interrupted-beam x-ray CT on diagnostic clinical scanners.

Authors:  Matthew J Muckley; Baiyu Chen; Thomas Vahle; Thomas O'Donnell; Florian Knoll; Aaron D Sodickson; Daniel K Sodickson; Ricardo Otazo
Journal:  Phys Med Biol       Date:  2019-08-07       Impact factor: 3.609

3.  PWLS-ULTRA: An Efficient Clustering and Learning-Based Approach for Low-Dose 3D CT Image Reconstruction.

Authors:  Xuehang Zheng; Saiprasad Ravishankar; Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

4.  Low-Dose CT Image Post-Processing Based on Learn-Type Sparse Transform.

Authors:  Wenfeng Zheng; Bo Yang; Ye Xiao; Jiawei Tian; Shan Liu; Lirong Yin
Journal:  Sensors (Basel)       Date:  2022-04-09       Impact factor: 3.847

5.  Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction.

Authors:  John W Garrett; Yinsheng Li; Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2018-04-01       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.