Literature DB >> 26684493

Comparison of incidence of dentinal defects after root canal preparation with continuous rotation and reciprocating instrumentation.

Prashant Monga1, Nitika Bajaj2, Pardeep Mahajan3, Shiwani Garg4.   

Abstract

Biomechanical preparation is one of the most important steps in endodontic therapy. Rotary instrumentation has facilitated this step. Nowadays the market is flooded with different types of rotary instruments. The present study compared the root dentinal crack formation with continuous rotating versus reciprocating root canal preparation methods. One hundred and fifty freshly extracted teeth were used for the study. They were divided into 5 groups with 30 teeth in each group. Thirty teeth were kept under control group A and no root canal preparation was done for this group. Another 30 teeth were prepared with hand files which were kept under control group B. In the experimental groups (sample size, n=30 each) root canals were prepared with ProTaper, K3XF rotary system and WaveOne. Sectioning of these teeth was done at 3, 6 and 9mm from the apex and were evaluated for the presence of any defects. Root dentinal cracks were produced with each type of rotary instruments. Statistical analysis showed no significant difference in root dentinal crack formation between control groups and WaveOne system. There was statistically significant difference in root dentinal crack formation when the canals were prepared with ProTaper and K3XF rotary system. So it was concluded, that continuous rotating instruments could produce dentinal crack formation. Root canal instruments with reciprocating movement appear to be a better option than continuous rotation movement.
Copyright © 2015. Published by Elsevier B.V.

Entities:  

Keywords:  Dentinal cracks; K3XF rotary system; ProTaper rotary; WaveOne

Year:  2015        PMID: 26684493     DOI: 10.1016/j.sdj.2015.09.003

Source DB:  PubMed          Journal:  Singapore Dent J        ISSN: 0377-5291


  5 in total

1.  Micro-computed tomography evaluation of dentinal microcracks following canal preparation with thermomechanically heat-treated engine-driven files.

Authors:  Sharmini Arumugam; Hsu Zenn Yew; Safura Anita Baharin; Jasmina Qamaruz Zaman; Andanastuti Muchtar; Shalini Kanagasingam
Journal:  Aust Endod J       Date:  2021-05-06       Impact factor: 1.719

2.  Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems.

Authors:  Azadeh Harandi; Sina Mirzaeerad; Mahgol Mehrabani; Elham Mahmoudi; Ali Bijani
Journal:  Iran Endod J       Date:  2017

3.  Synchrotron radiation-based micro-computed tomographic analysis of dentinal microcracks using rotary and reciprocating file systems: An in vitro study.

Authors:  Harikumar Vemisetty; N Tulasi Priya; Balwant Singh; Pooja Yenubary; Ashish Kumar Agarwal; Jayaprada Reddy Surakanti
Journal:  J Conserv Dent       Date:  2020-12-04

4.  Endoscopic findings in periapical surgery. A cross-sectional study of 206 roots.

Authors:  P Glera-Suárez; A Pallarés-Serrano; D Soto-Peñaloza; B Tarazona-Álvarez; M Peñarrocha-Diago; D Peñarrocha-Oltra
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2022-07-01

5.  Stereomicroscopic Evaluation of Microcrack Formation in Dentin by ProTaper Next, Revo S, and WaveOne Gold File System.

Authors:  Hena Rahman; Anil Chandra; Monika Khangwal; Akriti Goel; Vijay Kumar Shakya
Journal:  Contemp Clin Dent       Date:  2021-12-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.