| Literature DB >> 33551606 |
Harikumar Vemisetty1, N Tulasi Priya2, Balwant Singh3, Pooja Yenubary2, Ashish Kumar Agarwal3, Jayaprada Reddy Surakanti1.
Abstract
BACKGROUND: Advances in both X-ray sources and X-ray optics have dramatically improved the feasibility of these techniques in various fields. AIMS: We aimed to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Gold (PTG), Hyflex electrodischarge machining (HEDM), Reciproc (RPC), and WaveOne Gold (WOG) using synchrotron radiation-based micro-computed tomographic (SR-μCT) analysis. SUBJECTS AND METHODS: Forty mandibular molars were assigned to 4 experimental groups (n = 10) according to the file system used for the root canal preparation: Group 1: PTG (25/0.08), Group 2: HEDM (25/0.08), Group 3: RPC (25/0.08), and Group 4: WOG (25/0.07). The specimens were scanned on SR-μCT system before and after root canal preparation. The pre- and postoperative cross-sectional images (N = 183,200) of the mesial roots were screened to identify the presence of dentinal microcracks. The number of microcracks was determined as a percentage for each group. STATISTICAL ANALYSIS: There was no necessity of statistical analysis in the present study. The number of microcracks was determined as a percentage for each group.Entities:
Keywords: Dentinal microcracks; root canal preparation; synchrotron
Year: 2020 PMID: 33551606 PMCID: PMC7861079 DOI: 10.4103/JCD.JCD_465_20
Source DB: PubMed Journal: J Conserv Dent ISSN: 0972-0707
Figure 1Representative cross-sectional images of mesial roots of mandibular molars showing the presence of dentinal microcracks before and after preparation with ProTaper Gold, Hyflex electrodischarge machining, Reciproc, and Wave One Gold file systems
Tabular representation showing number of microcracks determined as a percentage for each group
| Variables | Total slices | Cracks | Percentage |
|---|---|---|---|
| Group 1 | 20,301 | 399 | 1.965 |
| Group 2 | 21,984 | 200 | 0.909 |
| Group 3 | 19,310 | 256 | 1.325 |
| Group 4 | 20,152 | 210 | 1.042 |
Among the four file systems tested, HEDM (0.9%) has a shown fewer number of new dentinal microcracks comparatively. HEDM=Hyflex electrodischarge machining