Literature DB >> 26675339

Utility of a Newly Designed Film Holder for Premolar Bitewing Radiography.

Yaser Safi1, Mohammad Esmaeelinejad2, Zahra Vasegh1, Solmaz Valizadeh1, Mohammad Mehdi Aghdasi3, Omid Sarani4, Mahmoud Afsahi5.   

Abstract

INTRODUCTION: Bitewing radiography is a valuable technique for assessment of proximal caries, alveolar crest and periodontal status. Technical errors during radiography result in erroneous radiographic interpretation, misdiagnosis, possible mistreatment or unnecessary exposure of patient for taking a repeat radiograph. AIM: In this study, we aimed to evaluate the efficacy of a film holder modified from the conventional one and compared it with that of conventional film holder.
MATERIALS AND METHODS: Our study population comprised of 70 patients who were referred to the Radiology Department for bilateral premolar bitewing radiographs as requested by their attending clinician. Bitewing radiographs in each patient were taken using the newly designed holder in one side and the conventional holder in the other side. The acceptability of the two holders from the perspectives of the technician and patients was determined using a 0-20 point scale. The frequency of overlap and film positioning errors was calculated for each method.
RESULTS: The conventional holder had greater acceptability among patients compared to the newly designed holder (mean score of 16.59 versus 13.37). From the technicians' point of view, the newly designed holder was superior to the conventional holder (mean score of 17.33 versus 16.44). The frequency of overlap was lower using the newly designed holder (p<0.001) and it allowed more accurate film positioning (p=0.005).
CONCLUSION: The newly designed holder may facilitate the process of radiography for technicians and may be associated with less frequency of radiographic errors compared to the conventional holder.

Entities:  

Keywords:  Cheek; Digital radiography; Inter-proximal radiographs

Year:  2015        PMID: 26675339      PMCID: PMC4668503          DOI: 10.7860/JCDR/2015/13769.6769

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  13 in total

1.  Evaluation of alveolar crest bone loss via premolar bitewing radiographs: presentation of a new method.

Authors:  Yaser Safi; Mahdi Kadkhodazadeh; Pooria Safai; Mohammad Esmaeelinejad; Nafiseh Shamloo
Journal:  J Periodontal Implant Sci       Date:  2014-10-29       Impact factor: 2.614

2.  Bitewing film quality: a clinical comparison of the loop vs. holder techniques.

Authors:  Suwadee Kositbowornchai; Tipsuda Phadannorg; Montira Permpoonsinsook; Bandit Thinkhamrop
Journal:  Quintessence Int       Date:  2004-04       Impact factor: 1.677

3.  Radiographic parameters as prognostic indicators for healing of class II furcation defects.

Authors:  Jacob Horwitz; Eli E Machtei; Peter Reitmeir; Rolf Holle; Ti-Sun Kim; Peter Eickholz
Journal:  J Clin Periodontol       Date:  2004-02       Impact factor: 8.728

4.  Practical and effective ALARA.

Authors:  Joseph John Bevelacqua
Journal:  Health Phys       Date:  2010-05       Impact factor: 1.316

Review 5.  An overview of radiographic film holders.

Authors:  D A Dixon; C F Hildebolt
Journal:  Dentomaxillofac Radiol       Date:  2005-03       Impact factor: 2.419

6.  Assessment of alveolar bone levels from bitewing, periapical and panoramic radiographs in periodontitis patients.

Authors:  R Gedik; I Marakoglu; S Demirer
Journal:  West Indian Med J       Date:  2008-09       Impact factor: 0.171

7.  Comparison of conventional dental radiographs and xeroradiographs using perceptibility curves.

Authors:  D A Miles; W D McDavid; U Welander; S Hockett
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1986-07

8.  Extraoral periapical radiography: an alternative approach to intraoral periapical radiography.

Authors:  Rahul Kumar; Neha Khambete; Ekta Priya
Journal:  Imaging Sci Dent       Date:  2011-12-19

9.  Utility of extra-oral aiming device in imaging periapical regions of posterior teeth.

Authors:  Sudhakar S; Ramaswamy P; Smitha B; Uday G
Journal:  J Clin Diagn Res       Date:  2014-10-20

10.  Pediatric bitewing film holder: preschoolers' acceptance and radiographs' diagnostic quality.

Authors:  Viviane Santos da Silva Pierro; Roberta Barcelos; Ivete Pomarico Ribeiro de Souza; Rubens Júnior Raymundo
Journal:  Pediatr Dent       Date:  2008 Jul-Aug       Impact factor: 1.874

View more
  2 in total

1.  Reproducibility and diagnostic value of a new wedge-guided bitewing image receptor-holding device.

Authors:  Deivi Cascante-Sequeira; Hugo Gaêta-Araujo; Danieli Moura Brasil; Deborah Queiroz Freitas; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2021-08-31       Impact factor: 2.419

2.  Development and validation of two new image receptor-holding devices for overlapping reduction of proximal surfaces in bitewing radiography: a preclinical study.

Authors:  Deivi Cascante-Sequeira; Hugo Gaêta-Araujo; Leonardo Vieira Peroni; Christiano Oliveira-Santos; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2021-01-06       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.