Literature DB >> 26653727

Anterior Capsulotomy Outcomes: A Comparison Between Two Femtosecond Laser Cataract Surgery Platforms.

Seth M Pantanelli, Vasilios F Diakonis, Zaina Al-Mohtaseb, Florence Cabot, Nilufer Yesilirmak, George A Kounis, Ibrahim O Sayed-Ahmed, Daniel Waren, Sonia H Yoo, Kendall E Donaldson.   

Abstract

PURPOSE: To compare capsulotomy outcomes between two femtosecond laser platforms for cataract surgery.
METHODS: This retrospective case series included 205 eyes of 162 consecutive patients (75 male and 87 female) aged 68.32 ± 10.27 years (range: 38 to 92 years) who underwent femtosecond laser-assisted cataract surgery (FLACS) using either the LenSx (Alcon Laboratories, Inc., Fort Worth, TX) or the Catalys (Abbott Medical Optics, Abbott Park, IL) laser platform. Intraoperative assessment of the capsulotomy was performed and graded as one of the following four types: complete treatment pattern (type 1), microadhesions (type 2), incomplete treatment pattern (type 3), and complete pattern but not continuous (type 4).
RESULTS: Ninety-seven eyes underwent FLACS using the LenSx platform and 108 eyes using the Catalys platform. Ninety-four capsulotomies in the LenSx group were graded as type 1 (96.91%), and three were graded as type 2 (3.09%); all capsulotomies in the Catalys group were graded as type 1 (100%). There was no statistically significant difference between the LenSx and Catalys groups (P > .05). No intraoperative complications (specifically, no posterior capsular extension or vitreous loss) were noticed in any of the eyes included in the study.
CONCLUSIONS: The LenSx and Catalys laser platforms demonstrate similar capsulotomy outcomes. The microadhesions that were demonstrated in three cases in the LenSx group did not lead to intraoperative or postoperative complications. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26653727     DOI: 10.3928/1081597X-20151118-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Safety and reliability of femtosecond laser-assisted cataract surgery for Japanese eyes.

Authors:  Hiroko Bissen-Miyajima; Manabu Hirasawa; Kunihiko Nakamura; Yuka Ota; Keiichiro Minami
Journal:  Jpn J Ophthalmol       Date:  2017-12-20       Impact factor: 2.447

2.  Inspection of the lens thickness with preoperative biometric measurements prevents an erroneous interpretation of posterior capsule during FLACS.

Authors:  Mei Kurosawa; Hiroshi Horiguchi; Takuya Shiba; Tadashi Nakano
Journal:  Sci Rep       Date:  2021-05-06       Impact factor: 4.379

Review 3.  Update and clinical utility of the LenSx femtosecond laser in cataract surgery.

Authors:  Timothy V Roberts; Michael Lawless; Gerard Sutton; Chris Hodge
Journal:  Clin Ophthalmol       Date:  2016-10-17

4.  Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery.

Authors:  Hung-Yuan Lin; Ya-Jung Chuang; Pi-Jung Lin
Journal:  Sci Rep       Date:  2021-05-04       Impact factor: 4.379

5.  Evaluation of femtosecond laser-assisted anterior capsulotomy in the presence of ophthalmic viscoelastic devices (OVDs).

Authors:  Hassan Mansoor; Yu-Chi Liu; Yoke Rung Wong; Nyein C Lwin; Xin Y Seah; Jodhbir S Mehta
Journal:  Sci Rep       Date:  2020-12-09       Impact factor: 4.379

6.  Electron microscopy analysis of femtosecond laser-assisted capsulotomy before and after lens fragmentation.

Authors:  Wolfgang J Mayer; Andreas Ohlmann; Anna Schuh; Siegfried Priglinger; Thomas Kohnen; Mehdi Shajari
Journal:  Sci Rep       Date:  2021-12-24       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.