Accuracy evaluation of a lower-cost and four higher-cost laser scanners.

Valentina Campanelli1, Stephen M Howell2, Maury L Hull3.   

Abstract

Knowing the accuracy of laser scanners is imperative to select the best scanner to generate bone models. However, errors stated by manufacturers may not apply to bones. The three objectives of this study were to determine: 1) whether the overall error stated by the manufacturers of five laser scanners was different from the root mean squared error (RMSE) computed by scanning a gage block; 2) the repeatability of 3D models generated by the laser scanners when scanning a complex freeform surface such as a distal femur and whether this differed from the repeatability when scanning a gage block; 3) whether the errors for one lower-cost laser scanner are comparable to those of four higher-cost laser scanners. The RMSEs in scanning the gage block were 2 to 52µm lower than the overall errors stated by the manufacturers. The repeatability in scanning the bovine femur 10 times was significantly worse than that in scanning the gage block 10 times. The precision of the lower-cost laser scanner was comparable to that of the higher-cost laser scanners, but the bias was an order of magnitude greater. The contributions of this study are that 1) the overall errors stated by the manufacturers are an upper bound when simple geometric objects like a gage block are scanned, 2) the repeatability is worse on average three times when scanning a complex freeform surface compared to scanning the gage block, and 3) the main difference between the lower-cost and the higher-cost laser scanners is the bias.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Creaform™; Laser Design™; Laser scanner; NextEngine™; Nikon™; Northern Digital™; Repeatability; Three-dimensional bone model

Mesh:

Year:  2015        PMID: 26652505     DOI: 10.1016/j.jbiomech.2015.11.015

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Kinematic alignment more closely restores the groove location and the sulcus angle of the native trochlea than mechanical alignment: implications for prosthetic design.

Authors:  Rocio Lozano; Valentina Campanelli; Stephen Howell; Maury Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-24       Impact factor: 4.342

2.  Quantifying wear depth in hip prostheses using a 3D optical scanner.

Authors:  Katherine A Hollar; Daniel S Ferguson; John B Everingham; Jillian L Helms; Kevin J Warburton; Trevor J Lujan
Journal:  Wear       Date:  2017-10-16       Impact factor: 3.892

3.  Implant placement accuracy in total knee arthroplasty: validation of a CT-based measurement technique.

Authors:  Valentina Campanelli; Rocio Lozano; Hosna Akhlaghpour; Abheetinder S Brar; David Maislin; Alexander J Nedopil; Joel Zuhars
Journal:  Quant Imaging Med Surg       Date:  2020-02

4.  Use of Miniature Step Gauges to Assess the Performance of 3D Optical Scanners and to Evaluate the Accuracy of a Novel Additive Manufacture Process.

Authors:  Maria Grazia Guerra; Leonardo De Chiffre; Fulvio Lavecchia; Luigi Maria Galantucci
Journal:  Sensors (Basel)       Date:  2020-01-29       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.