Literature DB >> 30220743

Quantifying wear depth in hip prostheses using a 3D optical scanner.

Katherine A Hollar1, Daniel S Ferguson2, John B Everingham1, Jillian L Helms1, Kevin J Warburton1, Trevor J Lujan1.   

Abstract

The visualization of wear depth in hip prostheses can assist the evaluation of new bearing materials and implant designs. The goal of this study was to develop an accurate, fast, and economical methodology to generate colorimetric maps of wear depth in hip implants using a structured light 3D optical scanning system. The accuracy and precision of this novel technique were determined using reference blocks with known wear depths. This technique was then used to measure the in vitro wear of a hip resurfacing device for canines that incorporates a highly cross-linked polyethylene liner. The 3D optical scanner had an average accuracy of 2.1 µm and an average precision of 1.4 µm, which corresponded to errors less than 10% when measuring wear depths of 20 µm or greater. The scanner was able to repeatedly generate 3D colorimetric maps of wear depth in highly cross-linked polyethylene liners in 20 min or less. These colorimetric maps identified localized regions with 3-fold greater wear than the average wear depth, and revealed liners with asymmetric wear patterns. For the first time, this study has validated the use of 3D optical scanning to quantify in vitro surface wear in a hip replacement device.

Entities:  

Keywords:  CMM; Colorimetric map; Highly cross-linked polyethylene; Hip simulator; Structured light; Wear map

Year:  2017        PMID: 30220743      PMCID: PMC6136671          DOI: 10.1016/j.wear.2017.10.008

Source DB:  PubMed          Journal:  Wear        ISSN: 0043-1648            Impact factor:   3.892


  21 in total

1.  Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Authors:  H McKellop; F W Shen; B Lu; P Campbell; R Salovey
Journal:  J Orthop Res       Date:  1999-03       Impact factor: 3.494

2.  Reliability of a PowerPoint method for wear measurement after total hip arthroplasty: a retrieval study using 3-dimensional laser scanning.

Authors:  Ho Hyun Yun; Won Yong Shon; Jung Ro Yoon; Jae-Hyuk Yang; Deuk-Soo Lim
Journal:  J Arthroplasty       Date:  2012-04-11       Impact factor: 4.757

3.  Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model.

Authors:  David Markel; Judd Day; Ryan Siskey; Imants Liepins; Steven Kurtz; Kevin Ong
Journal:  Int Orthop       Date:  2010-07-13       Impact factor: 3.075

4.  Validation of a three-dimensional facial scanning system based on structured light techniques.

Authors:  Lili Ma; Tianmin Xu; Jiuxiang Lin
Journal:  Comput Methods Programs Biomed       Date:  2009-03-20       Impact factor: 5.428

5.  Highly cross-linked polyethylene in hip resurfacing arthroplasty: long-term follow-up.

Authors:  Harlan C Amstutz; Karren M Takamura; Edward Ebramzadeh; Michel J Le Duff
Journal:  Hip Int       Date:  2014-10-17       Impact factor: 2.135

6.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

7.  Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners.

Authors:  Hee-Nee Pang; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

8.  Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years.

Authors:  James W Pritchett
Journal:  J Arthroplasty       Date:  2016-03-15       Impact factor: 4.757

9.  Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years.

Authors:  John Older
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

10.  Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners.

Authors:  Saverio Affatato; Maria Cristina Valigi; Silvia Logozzo
Journal:  Materials (Basel)       Date:  2017-03-30       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.