Literature DB >> 26625040

Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation.

Néstor Uribe-Patarroyo, Brett E Bouma.   

Abstract

We present a new technique for the correction of nonuniform rotation distortion in catheter-based optical coherence tomography (OCT), based on the statistics of speckle between A-lines using intensity-based dynamic light scattering. This technique does not rely on tissue features and can be performed on single frames of data, thereby enabling real-time image correction. We demonstrate its suitability in a gastrointestinal (GI) balloon-catheter OCT system, determining the actual rotational speed with high temporal resolution, and present corrected cross-sectional and en face views showing significant enhancement of image quality.

Entities:  

Mesh:

Year:  2015        PMID: 26625040      PMCID: PMC4720487          DOI: 10.1364/OL.40.005518

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  14 in total

1.  Correction of rotational distortion for catheter-based en face OCT and OCT angiography.

Authors:  Osman O Ahsen; Hsiang-Chieh Lee; Michael G Giacomelli; Zhao Wang; Kaicheng Liang; Tsung-Han Tsai; Benjamin Potsaid; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Lett       Date:  2014-10-15       Impact factor: 3.776

2.  Identifying intestinal metaplasia at the squamocolumnar junction by using optical coherence tomography.

Authors:  John A Evans; Brett E Bouma; Jason Bressner; Milen Shishkov; Gregory Y Lauwers; Mari Mino-Kenudson; Norman S Nishioka; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2006-09-20       Impact factor: 9.427

3.  Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography.

Authors:  B E Bouma; G J Tearney
Journal:  Opt Lett       Date:  1999-04-15       Impact factor: 3.776

4.  Azimuthal registration of image sequences affected by nonuniform rotation distortion.

Authors:  Gijs van Soest; Johan G Bosch; Antonius F W van der Steen
Journal:  IEEE Trans Inf Technol Biomed       Date:  2008-05

Review 5.  Optical coherence tomography– 15 years in cardiology.

Authors:  Taishi Yonetsu; Brett E Bouma; Koji Kato; James G Fujimoto; Ik-Kyung Jang
Journal:  Circ J       Date:  2013-07-12       Impact factor: 2.993

6.  Localized measurement of longitudinal and transverse flow velocities in colloidal suspensions using optical coherence tomography.

Authors:  Nicolás Weiss; Ton G van Leeuwen; Jeroen Kalkman
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2013-10-28

7.  Fast rigid registration of vascular structures in IVUS sequences.

Authors:  Carlo Gatta; Oriol Pujol; Oriol Rodriguez Leor; Josepa Mauri Ferre; Petia Radeva
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-07-28

8.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

9.  Volumetric laser endomicroscopy in Barrett's esophagus: a feasibility study on histological correlation.

Authors:  A Swager; D F Boerwinkel; D M de Bruin; B L Weusten; D J Faber; S L Meijer; T G van Leeuwen; W L Curvers; J J Bergman
Journal:  Dis Esophagus       Date:  2015-05-08       Impact factor: 3.429

10.  Dynamic light scattering optical coherence tomography.

Authors:  Jonghwan Lee; Weicheng Wu; James Y Jiang; Bo Zhu; David A Boas
Journal:  Opt Express       Date:  2012-09-24       Impact factor: 3.894

View more
  21 in total

1.  Noise and bias in optical coherence tomography intensity signal decorrelation.

Authors:  Néstor Uribe-Patarroyo; Anouk L Post; Sebastián Ruiz-Lopera; Dirk J Faber; Brett E Bouma
Journal:  OSA Contin       Date:  2020-03-17

2.  Localized compliance measurement of the airway wall using anatomic optical coherence elastography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Hillel Price; Carlton Zdanski; Sorin Mitran; Amy L Oldenburg
Journal:  Opt Express       Date:  2019-06-10       Impact factor: 3.894

3.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

4.  Airway compliance measured by anatomic optical coherence tomography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Nicusor Iftimia; Hillel Price; Carlton Zdanski; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2017-03-15       Impact factor: 3.732

5.  Intravascular optical coherence tomography [Invited].

Authors:  Brett E Bouma; Martin Villiger; Kenichiro Otsuka; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

6.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

7.  Volumetric non-local-means based speckle reduction for optical coherence tomography.

Authors:  Carlos Cuartas-Vélez; René Restrepo; Brett E Bouma; Néstor Uribe-Patarroyo
Journal:  Biomed Opt Express       Date:  2018-06-26       Impact factor: 3.732

8.  Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source.

Authors:  Kaicheng Liang; Osman O Ahsen; Zhao Wang; Hsiang-Chieh Lee; Wenxuan Liang; Benjamin M Potsaid; Tsung-Han Tsai; Michael G Giacomelli; Vijaysekhar Jayaraman; Hiroshi Mashimo; Xingde Li; James G Fujimoto
Journal:  Opt Lett       Date:  2017-08-15       Impact factor: 3.776

9.  Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.

Authors:  Hsiang-Chieh Lee; Osman Oguz Ahsen; Kaicheng Liang; Zhao Wang; Cody Cleveland; Lucas Booth; Benjamin Potsaid; Vijaysekhar Jayaraman; Alex E Cable; Hiroshi Mashimo; Robert Langer; Giovanni Traverso; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2016-07-05       Impact factor: 3.732

10.  Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Authors:  Oscar Caravaca Mora; Philippe Zanne; Lucile Zorn; Florent Nageotte; Natalia Zulina; Sara Gravelyn; Paul Montgomery; Michel de Mathelin; Bernard Dallemagne; Michalina J Gora
Journal:  Biomed Opt Express       Date:  2020-02-03       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.